Search results for: Mai̇de Altuntaş
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 7

Search results for: Mai̇de Altuntaş

7 FMCW Doppler Radar Measurements with Microstrip Tx-Rx Antennas

Authors: Yusuf Ulaş Kabukçu, Si̇nan Çeli̇k, Onur Salan, Mai̇de Altuntaş, Mert Can Dalkiran, Gökseni̇n Bozdağ, Metehan Bulut, Fati̇h Yaman

Abstract:

This study presents a more compact implementation of the 2.4GHz MIT Coffee Can Doppler Radar for 2.6GHz operating frequency. The main difference of our prototype depends on the use of microstrip antennas which makes it possible to transport with a small robotic vehicle. We have designed our radar system with two different channels: Tx and Rx. The system mainly consists of Voltage Controlled Oscillator (VCO) source, low noise amplifiers, microstrip antennas, splitter, mixer, low pass filter, and necessary RF connectors with cables. The two microstrip antennas, one is element for transmitter and the other one is array for receiver channel, was designed, fabricated and verified by experiments. The system has two operation modes: speed detection and range detection. If the switch of the operation mode is ‘Off’, only CW signal transmitted for speed measurement. When the switch is ‘On’, CW is frequency-modulated and range detection is possible. In speed detection mode, high frequency (2.6 GHz) is generated by a VCO, and then amplified to reach a reasonable level of transmit power. Before transmitting the amplified signal through a microstrip patch antenna, a splitter used in order to compare the frequencies of transmitted and received signals. Half of amplified signal (LO) is forwarded to a mixer, which helps us to compare the frequencies of transmitted and received (RF) and has the IF output, or in other words information of Doppler frequency. Then, IF output is filtered and amplified to process the signal digitally. Filtered and amplified signal showing Doppler frequency is used as an input of audio input of a computer. After getting this data Doppler frequency is shown as a speed change on a figure via Matlab script. According to experimental field measurements the accuracy of speed measurement is approximately %90. In range detection mode, a chirp signal is used to form a FM chirp. This FM chirp helps to determine the range of the target since only Doppler frequency measured with CW is not enough for range detection. Such a FMCW Doppler radar may be used in border security of the countries since it is capable of both speed and range detection.

Keywords: doppler radar, FMCW, range detection, speed detection

Procedia PDF Downloads 356
6 The Evaluation of the Patients Related to Numeric Pain Scales: The Case of Turkey

Authors: Maide Yesilyurt, Saide Faydalı

Abstract:

Patients experience pain at different intensities in postoperative. The diagnosis of the pain, the assessment and the success of the treatment and care make the measurement of this finding compulsory. The aim of the study is to determine the evaluation differences numeric pain scales. The descriptive study was conducted with 360 patients with in postoperative. The data were obtained from questionnaires related to six numeric pain scales most preferred in clinical use, and a face-to-face interview technique was used by the researcher. Regarding to numeric pain scale, questions include forth positive and one negative statement. In evaluating the data; chi-square and Pearson correlation tests were used. For the study, the patients’ informed consents, the institution and the ethics committee received permission. In this study, patients' ages are between 18-80, 95.8% of the patients were not informed about pain assessment. Patients evaluated the 5-item numeric scale as the easy, can be answered quickly, accurate, and appropriate for clinical use and the 101 items numeric scale as complex than other scales. Regarding to numeric pain scales with positive statements between age, marital status, educational status, previous surgery, having chronic disease and getting information about pain assessment significant difference has been detected. All numeric pain scales are correlated to each other. As a result, it was determined that as the items in the numerical scales decreased, the patients were able to perceive the scales better, and the items in the scales increased, the patients were in trouble to understand.

Keywords: numeric pain scales, nurse, pain assessment, patient

Procedia PDF Downloads 259
5 Production of Spherical Cementite within Bainitic Matrix Microstructures in High Carbon Powder Metallurgy Steels

Authors: O. Altuntaş, A. Güral

Abstract:

The hardness-microstructure relationships of spherical cementite in bainitic matrix obtained by a different heat treatment cycles carried out to high carbon powder metallurgy (P/M) steel were investigated. For this purpose, 1.5 wt.% natural graphite powder admixed in atomized iron powders and the mixed powders were compacted under 700 MPa at room temperature and then sintered at 1150 °C under a protective argon gas atmosphere. The densities of the green and sintered samples were measured via the Archimedes method. A density of 7.4 g/cm3 was obtained after sintering and a density of 94% was achieved. The sintered specimens having primary cementite plus lamellar pearlitic structures were fully quenched from 950 °C temperature and then over-tempered at 705 °C temperature for 60 minutes to produce spherical-fine cementite particles in the ferritic matrix. After by this treatment, these samples annealed at 735 °C temperature for 3 minutes were austempered at 300 °C salt bath for a period of 1 to 5 hours. As a result of this process, it could be able to produced spherical cementite particle in the bainitic matrix. This microstructure was designed to improve wear and toughness of P/M steels. The microstructures were characterized and analyzed by SEM and micro and macro hardness.

Keywords: powder metallurgy steel, bainite, cementite, austempering and spheroidization heat treatment

Procedia PDF Downloads 122
4 Preparation and Antioxidant Activity of Heterocyclic Indole Derivatives

Authors: Tunca Gul Altuntas, Aziz Baydar, Cemre Acar, Sezen Yılmaz, Tulay Coban

Abstract:

Free radicals, which are generated in many bioorganic redox processes, play a role in the pathogenesis of several diseases including cancer, arthritis, hemorrhagic shock, inflammatory, cardiovascular, neurodegenerative diseases and age-related degenerative brain diseases. Exposures of normal cell to free radical damages several structures, oxidizes nucleic acids, proteins, lipids, or DNA. Compounds interfere with the action of reactive oxygen species might be useful in prevention and treatment of these pathologies. A series of indole compounds containing piperazine ring were synthesized. Coupling of indole-2-carboxylic acid with monosubstituted piperazines was accomplished with 1,1’-carbonyldiimidazole (CDI) in a good yield. The structures of prepared compounds were verified in good agreement with their 1H NMR (nuclear magnetic resonance), MS (mass spectrophotometry), and IR (infrared spectrophotometry) characteristics. In this work, all synthetized indole derivatives were screened in vitro for their antioxidative potential against vitamin E (α-tocopherol) using different antioxidant assays such as superoxide anion formation, lipid peroxidation levels in rat liver, and 2,2-diphenyl-1-picrylhydrazyl (DPPH) stable radical scavenging activity. The synthesized compounds showed various levels of inhibition compared to vitamin E. This may give promising results for the development of new antioxidant agents.

Keywords: antioxidant, indoles, piperazines, reactive oxygen species

Procedia PDF Downloads 200
3 The Effect of Organizational Justice on Management by Values Perception and Intention to Leave: A Study among Nurses

Authors: Arzu K. Harmanci Seren, Burcu Alacam, Serap Altuntas, Ulku Baykal

Abstract:

Organizational justice has been evaluated as a concept related to rules developed with regards to distributing gains and making decisions of distribution such as duty, goods, service, reward, punishment, fee, organizational position, opportunity or role among those working in that organization, and to social norms on which these rules are based. Studies of organizational justice are crucial for analyzing the organizational life. It is considered that organization justice will be positively influential upon organizational behaviours such as employees’ level of work satisfaction, their performance, and behaviours of organization citizenship, management by values perception, tendency towards cooperation, and towards quitting their jobs. However, when the literature related to health and nurse management is examined, authors could not reach enough findings related to the influence of nurses’ perception of organizational justice upon the perception of management and the intention of quitting in accordance with the values. For that reason, this study has been carried out with the purpose of determining the influence of nurses’ perception of organizational justice upon the perception of management and the intention of quitting in accordance with the values. The study has been carried out with 176 nurses working in a university hospital in Istanbul and a private hospital who accepted to take part in the study, and it is definitive and relation-seeking. Before the data has been collected, ethics committee approval and institutional permissions have been taken, Organizational Justice Scale, Management by Values, Intention to Leave Scale with a questionnaire including 8 questions that aims at defining the personal and professional characteristics of the nurses have been used as a means of data collection. The data collected between 1 May and 20 June 2016 have been evaluated by the researchers in a computer via definitive, relation-seeking and psychometric statistic. As a result of the study, it has been determined that most of the nurses are working in a university hospital (70.5%), that they are 30 and over (49.4%), women (91.5%), single (52.8%) and have a Bachelor’s Degree (48.3%), working in a surgery unit (17.6), have 5 year or less institutional experience (44.9%), 11 year or more professional experience. Cronbach alpha values of the scales used in this study are .94, .95 and .56. Nurses’ average scores of Organizational Justice Scale is M= 3.35±.96, Management by Values Scale is M=3.30±.74, Intention to Leave Scale is M=8.36±3.14. As a result of the analysis carried out in order to determine the influence of nurses’ perception of organizational justice upon the perception of management and the intention of quitting in accordance with the values, it has been pointed out that the Perception of Organizational Justice influenced the perception of Management by Values positively, Intention to Leave negatively.

Keywords: intention to leave, management by values, nursing, organizational justice

Procedia PDF Downloads 238
2 Detection of Alzheimer's Protein on Nano Designed Polymer Surfaces in Water and Artificial Saliva

Authors: Sevde Altuntas, Fatih Buyukserin

Abstract:

Alzheimer’s disease is responsible for irreversible neural damage of brain parts. One of the disease markers is Amyloid-β 1-42 protein that accumulates in the brain in the form plaques. The basic problem for detection of the protein is the low amount of protein that cannot be detected properly in body liquids such as blood, saliva or urine. To solve this problem, tests like ELISA or PCR are proposed which are expensive, require specialized personnel and can contain complex protocols. Therefore, Surface-enhanced Raman Spectroscopy (SERS) a good candidate for detection of Amyloid-β 1-42 protein. Because the spectroscopic technique can potentially allow even single molecule detection from liquid and solid surfaces. Besides SERS signal can be improved by using nanopattern surface and also is specific to molecules. In this context, our study proposes to fabricate diagnostic test models that utilize Au-coated nanopatterned polycarbonate (PC) surfaces modified with Thioflavin - T to detect low concentrations of Amyloid-β 1-42 protein in water and artificial saliva medium by the enhancement of protein SERS signal. The nanopatterned PC surface that was used to enhance SERS signal was fabricated by using Anodic Alumina Membranes (AAM) as a template. It is possible to produce AAMs with different column structures and varying thicknesses depending on voltage and anodization time. After fabrication process, the pore diameter of AAMs can be arranged with dilute acid solution treatment. In this study, two different columns structures were prepared. After a surface modification to decrease their surface energy, AAMs were treated with PC solution. Following the solvent evaporation, nanopatterned PC films with tunable pillared structures were peeled off from the membrane surface. The PC film was then modified with Au and Thioflavin-T for the detection of Amyloid-β 1-42 protein. The protein detection studies were conducted first in water via this biosensor platform. Same measurements were conducted in artificial saliva to detect the presence of Amyloid Amyloid-β 1-42 protein. SEM, SERS and contact angle measurements were carried out for the characterization of different surfaces and further demonstration of the protein attachment. SERS enhancement factor calculations were also completed via experimental results. As a result, our research group fabricated diagnostic test models that utilize Au-coated nanopatterned polycarbonate (PC) surfaces modified with Thioflavin-T to detect low concentrations of Alzheimer’s Amiloid – β protein in water and artificial saliva medium. This work was supported by The Scientific and Technological Research Council of Turkey (TUBITAK) Grant No: 214Z167.

Keywords: alzheimer, anodic aluminum oxide, nanotopography, surface enhanced Raman spectroscopy

Procedia PDF Downloads 258
1 Investigation of Alumina Membrane Coated Titanium Implants on Osseointegration

Authors: Pinar Erturk, Sevde Altuntas, Fatih Buyukserin

Abstract:

In order to obtain an effective integration between an implant and a bone, implant surfaces should have similar properties to bone tissue surfaces. Especially mimicry of the chemical, mechanical and topographic properties of the implant to the bone is crucial for fast and effective osseointegration. Titanium-based biomaterials are more preferred in clinical use, and there are studies of coating these implants with oxide layers that have chemical/nanotopographic properties stimulating cell interactions for enhanced osseointegration. There are low success rates of current implantations, especially in craniofacial implant applications, which are large and vital zones, and the oxide layer coating increases bone-implant integration providing long-lasting implants without requiring revision surgery. Our aim in this study is to examine bone-cell behavior on titanium implants with an aluminum oxide layer (AAO) on effective osseointegration potential in the deformation of large zones with difficult spontaneous healing. In our study, aluminum layer coated titanium surfaces were anodized in sulfuric, phosphoric, and oxalic acid, which are the most common used AAO anodization electrolytes. After morphologic, chemical, and mechanical tests on AAO coated Ti substrates, viability, adhesion, and mineralization of adult bone cells on these substrates were analyzed. Besides with atomic layer deposition (ALD) as a sensitive and conformal technique, these surfaces were coated with pure alumina (5 nm); thus, cell studies were performed on ALD-coated nanoporous oxide layers with suppressed ionic content too. Lastly, in order to investigate the effect of the topography on the cell behavior, flat non-porous alumina layers on silicon wafers formed by ALD were compared with the porous ones. Cell viability ratio was similar between anodized surfaces, but pure alumina coated titanium and anodized surfaces showed a higher viability ratio compared to bare titanium and bare anodized ones. Alumina coated titanium surfaces, which anodized in phosphoric acid, showed significantly different mineralization ratios after 21 days over other bare titanium and titanium surfaces which anodized in other electrolytes. Bare titanium was the second surface that had the highest mineralization ratio. Otherwise, titanium, which is anodized in oxalic acid electrolyte, demonstrated the lowest mineralization. No significant difference was shown between bare titanium and anodized surfaces except AAO titanium surface anodized in phosphoric acid. Currently, osteogenic activities of these cells on the genetic level are investigated by quantitative real-time polymerase chain reaction (qRT-PCR) analysis results of RUNX-2, VEGF, OPG, and osteopontin genes. Also, as a result of the activities of the genes mentioned before, Western Blot will be used for protein detection. Acknowledgment: The project is supported by The Scientific and Technological Research Council of Turkey.

Keywords: alumina, craniofacial implant, MG-63 cell line, osseointegration, oxalic acid, phosphoric acid, sulphuric acid, titanium

Procedia PDF Downloads 95