Search results for: Macintosh laryngoscopy
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 7

Search results for: Macintosh laryngoscopy

7 A Comparison between the McGrath Video Laryngoscope and the Macintosh Laryngoscopy in Children with Expected Normal Airway

Authors: Jong Yeop Kim, Ji Eun Kim, Hyun Jeong Kwak, Sook Young Lee

Abstract:

Background: This prospective, randomized, controlled study was performed to evaluate the usefulness of the McGrath VL compared to Macintosh laryngoscopy in children with expected normal airway during endotracheal intubation, by comparing the time to intubation and ease of intubation. Methods: Eighty-four patients, aged 1-10 years undergoing endotracheal intubation for elective surgery were randomly assigned to McGrath group (n = 42) or Macintosh group (n = 42). Anesthesia was induced with propofol 2.5-3.0 mg/kg and sevoflurane 5-8 vol%. Orotracheal intubation was performed 2 minutes after injection of rocuronium 0.6 mg/kg with McGrath VL or Macintosh laryngoscope. The primary outcome was time to intubation. The Cormack and Lehane glottic grade, intubation difficulty score (IDS), and success rate of intubation were assessed. Hemodynamic changes also were recorded. Results: Median time to intubation [interquartile range] was not different between the McGrath group and the Macintosh group (25.0 [22.8-28.3] s vs. 26.0 [24.0-29.0] s, p = 0.301). The incidence of grade I glottic view was significantly higher in theMcGrath group than in the Macintosh group (95% vs. 74%, p = 0.013). Median IDS was lower in the McGrath group than in the Macintosh group (0 [0-0] vs. 0 [0-1], p = 0.018). There were no significant differences in success rate on intubation or hemodynamics between the two groups. Conclusions: McGrath VL provides better laryngeal views and lower IDS, but similar intubation times and success rates compared to the Macintosh laryngoscope in children with the normal airway.

Keywords: intubation, Macintosh laryngoscopy, Mcgrath videolaryngoscopy, pediatrics

Procedia PDF Downloads 200
6 Comparison of Mcgrath, Pentax, and Macintosh Laryngoscope in Normal and Cervical Immobilized Manikin by Novices

Authors: Jong Yeop Kim, In Kyong Yi, Hyun Jeong Kwak, Sook Young Lee, Sung Yong Park

Abstract:

Background: Several video laryngoscopes (VLs) were used to facilitate tracheal intubation in the normal and potentially difficult airway, especially by novice personnel. The aim of this study was to compare tracheal intubation performance regarding the time to intubation, glottic view, difficulty, and dental click, by a novice using McGrath VL, Pentax Airway Scope (AWS) and Macintosh laryngoscope in normal and cervical immobilized manikin models. Methods: Thirty-five anesthesia nurses without previous intubation experience were recruited. The participants performed endotracheal intubation in a manikin model at two simulated neck positions (normal and fixed neck via cervical immobilization), using three different devices (McGrath VL, Pentax AWS, and Macintosh direct laryngoscope) at three times each. Performance parameters included intubation time, success rate of intubation, Cormack Lehane laryngoscope grading, dental click, and subjective difficulty score. Results: Intubation time and success rate at the first attempt were not significantly different between the 3 groups in normal airway manikin. In the cervical immobilized manikin, the intubation time was shorter (p = 0.012) and the success rate with the first attempt was significantly higher (p < 0.001) when using McGrath VL and Pentax AWS compared with Macintosh laryngoscope. Both VLs showed less difficulty score (p < 0.001) and more Cormack Lehane grade I (p < 0.001). The incidence of dental clicks was higher with McGrath VL than Macintosh laryngoscope in the normal and cervical immobilized airway (p = 0.005, p < 0.001, respectively). Conclusion: McGrath VL and Pentax AWS resulted in shorter intubation time, higher first attempt success rate, compared with Macintosh laryngoscope by a novice intubator in a cervical immobilized manikin model. McGrath VL could be reduced the risk of dental injury compared with Macintosh laryngoscope in this scenario.

Keywords: intubation, manikin, novice, videolaryngoscope

Procedia PDF Downloads 119
5 Pentax Airway Scope Video Laryngoscope for Orotracheal Intubation in Children: A Randomized Controlled Trial

Authors: In Kyong Yi, Yun Jeong Chae, Jihoon Hwang, Sook-Young Lee, Jong-Yeop Kim

Abstract:

Background: Pentax airway scope (AWS) is a recently developed video laryngoscope for use in both normal and difficult airways, providing a good laryngeal view. The purpose of this randomized noninferior study was to evaluate the efficacy of the Pentax-AWS regarding intubation time, laryngeal view and ease of intubation in pediatric patients with normal airway, compared to Macintosh laryngoscope. Method: A total of 136 pediatric patients aged 1 to 10 with American Society of Anesthesiologists physical status I or II undergoing general anesthesia required orotracheal intubation were randomly allocated into two groups: Macintosh laryngoscope (n =68) and Pentax AWS (n=68). Anesthesia was induced with propofol, rocuronium, and sevoflurane. The primary outcome was intubation time. Cormack-Lehane laryngeal view grade, application of optimal laryngeal external manipulation (OELM), intubation difficulty scale (IDS), intubation failure rate and adverse events were also measured. Result: No significant difference was observed between the two groups regarding intubation time (Macintosh; 23[22-26] sec vs. Pentax; 23.5[22-27.75] sec, p=0.713). As for the laryngeal view grade, the Pentax group showed less number of grade 2a or higher grade cases compared to the Macintosh group (1/2a/2b/3; 52.9%/41.2%/4.4%/1.5% vs. 98.5%/1.5%/0%/0%, p=0.000). No optimal laryngeal external manipulation application was required in the Pentax group (38.2% vs. 0%, p=0.000). Intubation difficulty scale resulted in lower values for Pentax group (0 [0-2] vs. 0 [0-0.55], p=0.001). Failure rate was not different between the two groups (1.5% vs. 4.4%, p=0.619). Adverse event-wise, slightly higher incidence of bleeding (1.5% vs. 5.9%, p=0.172) and teeth injury (0% vs. 5.9%, p=0.042) occurred in the Pentax group. Conclusion: In conclusion, Pentax-AWS provided better laryngeal view, similar intubation time and similar success rate compared with Macintosh laryngoscope in children with normal airway. However, the risk of teeth injury might increase and warrant special attention.

Keywords: Pentax-AWS, pediatric, video laryngoscope, intubation

Procedia PDF Downloads 162
4 Proof of Concept of Video Laryngoscopy Intubation: Potential Utility in the Pre-Hospital Environment by Emergency Medical Technicians

Authors: A. Al Hajeri, M. E. Minton, B. Haskins, F. H. Cummins

Abstract:

The pre-hospital endotracheal intubation is fraught with difficulties; one solution offered has been video laryngoscopy (VL) which permits better visualization of the glottis than the standard method of direct laryngoscopy (DL). This method has resulted in a higher first attempt success rate and fewer failed intubations. However, VL has mainly been evaluated by experienced providers (experienced anesthetists), and as such the utility of this device for those whom infrequently intubate has not been thoroughly assessed. We sought to evaluate this equipment to determine whether in the hands of novice providers this equipment could prove an effective airway management adjunct. DL and two VL methods (C-Mac with distal screen/C-Mac with attached screen) were evaluated by simulating practice on a Laerdal airway management trainer manikin. Twenty Emergency Medical Technicians (basics) were recruited as novice practitioners. This group was used to eliminate bias, as these clinicians had no pre-hospital experience of intubation (although they did have basic airway skills). The following areas were assessed: Time taken to intubate, number of attempts required to successfully intubate, ease of use of equipment VL (attached screen) took on average longer for novice clinicians to successfully intubate and had a lower success rate and reported higher rating of difficulty compared to DL. However, VL (with distal screen) and DL were comparable on intubation times, success rate, gastric inflation rate and rating of difficulty by the user. This study highlights the routine use of VL by inexperienced clinicians would be of no added benefit over DL. Further studies are required to determine whether Emergency Medical Technicians (Paramedics) would benefit from this airway adjunct, and ascertain whether after initial mastery of VL (with a distal screen), lower intubation times and difficulty rating may be achievable.

Keywords: direct laryngoscopy, endotracheal intubation, pre-hospital, video laryngoscopy

Procedia PDF Downloads 378
3 Disparate Use of Chemical and Physical Restraints in the Emergency Department by Race/Ethnicity

Authors: Etta Conteh, Tracy Macintosh

Abstract:

Introduction: Restraints are often used in the Emergency Department when it is necessary for a patient to be restrained in order to decrease their agitation and better treat them. Chemical and physical restraints may be used on these patients at the discretion of the medical provider. Racism and injustice are rampant within our country, and medicine and healthcare are not spared. While racism and racial bias in medicine and healthcare have been studied, information on the differences in the use of restraints by race are scarce. Objective: The objective of this study is to determine if African Americans and Hispanic-American patients are restrained at higher rates compared to their White counterparts. Methods: This study will be carried out through a retrospective analysis utilizing the Hospital Corporation of America (HCA) national Emergency Department (ED) and inpatient database with patient visits from 2016-2019. All patient visits, with patients aged 18 years or older, will be reviewed, looking specifically for the race and the use and type of restraints. Other factors, such a pre-existing psychiatric condition, will be used for sub-analysis. Rationale: The outcome of this project will demonstrate the absence or presence of a racial disparity in the use of restraints in the Emergency Department. These results can be used as a foundation for improving racial equity in healthcare treatment.

Keywords: emergency medicine, public health, racism, restraint use

Procedia PDF Downloads 228
2 A Normalized Non-Stationary Wavelet Based Analysis Approach for a Computer Assisted Classification of Laryngoscopic High-Speed Video Recordings

Authors: Mona K. Fehling, Jakob Unger, Dietmar J. Hecker, Bernhard Schick, Joerg Lohscheller

Abstract:

Voice disorders origin from disturbances of the vibration patterns of the two vocal folds located within the human larynx. Consequently, the visual examination of vocal fold vibrations is an integral part within the clinical diagnostic process. For an objective analysis of the vocal fold vibration patterns, the two-dimensional vocal fold dynamics are captured during sustained phonation using an endoscopic high-speed camera. In this work, we present an approach allowing a fully automatic analysis of the high-speed video data including a computerized classification of healthy and pathological voices. The approach bases on a wavelet-based analysis of so-called phonovibrograms (PVG), which are extracted from the high-speed videos and comprise the entire two-dimensional vibration pattern of each vocal fold individually. Using a principal component analysis (PCA) strategy a low-dimensional feature set is computed from each phonovibrogram. From the PCA-space clinically relevant measures can be derived that quantify objectively vibration abnormalities. In the first part of the work it will be shown that, using a machine learning approach, the derived measures are suitable to distinguish automatically between healthy and pathological voices. Within the approach the formation of the PCA-space and consequently the extracted quantitative measures depend on the clinical data, which were used to compute the principle components. Therefore, in the second part of the work we proposed a strategy to achieve a normalization of the PCA-space by registering the PCA-space to a coordinate system using a set of synthetically generated vibration patterns. The results show that owing to the normalization step potential ambiguousness of the parameter space can be eliminated. The normalization further allows a direct comparison of research results, which bases on PCA-spaces obtained from different clinical subjects.

Keywords: Wavelet-based analysis, Multiscale product, normalization, computer assisted classification, high-speed laryngoscopy, vocal fold analysis, phonovibrogram

Procedia PDF Downloads 230
1 A Case Report on Anesthetic Considerations in a Neonate with Isolated Oesophageal Atresia with Radiological Fallacy

Authors: T. Rakhi, Thrivikram Shenoy

Abstract:

Esophageal atresia is a disorder of maldevelopment of esophagus with or without a connection to the trachea. Radiological reviews are needed in consultation with the pediatric surgeon and neonatologist and we report a rare case of esophageal atresia associated with atrial septal defect-patent ductus arteriosus complex. A 2-day old female baby born at term, weighing 3.010kg, admitted to the Neonatal Intensive Care Unit with respiratory distress and excessive oral secretions. On examination, continuous murmur and cyanosis were seen. Esophageal atresia was suspected, after a failed attempt to pass a nasogastric tube. Chest radiograph showed coiling of the nasogastric tube and absent gas shadow in the abdomen. Echocardiography confirmed Patent Ductus Arteriosus with Atrial Septal Defect not in failure and was diagnosed with esophageal atresia with suspected fistula posted for surgical repair. After preliminary management with oxygenation, suctioning in prone position and antibiotics, investigations revealed Hb 17gms serum biochemistry, coagulation profile and C-Reactive Protein Test normal. The baby was premedicated with 5mcg of fentanyl and 100 mcg of midazolam and a rapid awake laryngoscopy was done to rule out difficult airway followed by induction with o2 air, sevo and atracurium 2 mg. Placement of a 3.5 tube was uneventful at first attempt and after confirming bilateral air entry positioned in the lateral position for Right thoracotomy. A pulse oximeter, Echocardiogram, Non-invasive Blood Pressure, temperature and a precordial stethoscope in left axilla were essential monitors. During thoracotomy, both the ends of the esophagus and the fistula could not be located after thorough search suggesting an on table finding of type A esophageal atresia. The baby was repositioned for gastrostomy, and cervical esophagostomy ventilated overnight and extubated uneventful. Absent gas shadow was overlooked and the purpose of this presentation is to create an awareness between the neonatologist, pediatric surgeons and anesthesiologist regarding variation of typing of Tracheoesophageal fistula pre and intraoperatively. A need for imaging modalities warranted for a definitive diagnosis in the presence of a gasless stomach.

Keywords: anesthetic, atrial septal defects, esophageal atresia, patent ductus arteriosus, perioperative, chest x-ray

Procedia PDF Downloads 146