Search results for: Lotfali Pourkazemi
3 Effects of Long Term Whole Body Vibration Training on Lipid Profile of Young Men
Authors: Farshad Ghazalian, Laleh Hakemi, Lotfali Pourkazemi, Maryam Ameri, Seyed Hossein Alavi
Abstract:
Background: The use of whole body vibration (WBV) as an exercise method has rapidly increased over the last decade. The aim of this study was to evaluate long term effects of different amplitudes of whole body vibration training with progressive frequencies on lipid profile of young healthy men. Materials and methods: Thirty three healthy male students were divided randomly in three groups: high amplitude vibration group (n=11), low amplitude vibration group (n=11), and control group (n=11). The vibration training consisted of 5 week whole-body vibration 3 times a week with amplitudes 4 and 2 mm and progressive frequencies from 25 Hz with increments of 5 Hz weekly. Concentrations TG, HDL, LDL, cholesterol, and VLDL before and after 5 weeks of training were measured in plasma samples. Statistical analysis was done using one way analysis of variance. P<0.05 was considered statistically significant. Results: The most important result of the present study is finding no favorable changes of 5-week vibration training with different amplitudes on blood lipid profiles. Discussion and conclusions: It was emphasized that in vibration training there should be a relationship between intensity and volume of exercise and lipid responses in order to improve blood lipoprotein profiles.Keywords: long term, body, vibration training, lipid
Procedia PDF Downloads 4192 The First Fungal Identification from Mini-BAL of Critical COVID-19 Patients
Authors: Fatemeh Fallah, Ensieh Lotfali, Leila Azimi, Hannan Khodaei, Maryam Rajabnejad, Nafiseh Abdollahi, Hossein Tayebi, Saham Ansari, Saeedeh Yaghoubi, Abdollah Karimi
Abstract:
Background: Coronavirus disease 2019 (COVID-19) has become a worldwide issue due to its high prevalence and rapid transmission. Fungal infections have been detected in COVID-19 patients, leading to increased morbidity and mortality. Objectives: This study aimed to isolate Aspergillus fumigatus and Mucor spp. on mini-bronchoalveolar lavage samples obtained from children with COVID-19 hospitalized in an Iranian children’s hospital. Methods: A cross-sectional descriptive study was performed on mini-bronchoalveolar lavage samples from children confirmed positive for COVID-19 admitted to ICU with a ventilator from April 2021 to February 2022. Demographic characteristics were recorded, and fungal DNA was extracted from mini-BAL samples taken from children. Nested PCR was made with two primers for Aspergillus fumigatus and Mucor spp. Results: Out of 100 children with COVID-19, all samples were negative for Aspergillus fumigatus; however, 12 cases were positive for BAL PCR for Mucor spp. Among the 12 patients, fever, shortness of breath, cough, and decreased level of consciousness were reported in 8.3% (n: 1), 16.6% (n: 2), 25% (n: 3), and 25% (n: 3), respectively. Most cases (41.7%; n: 5) suffered from heart disease, followed by underlying malignancy (33.4%; n: 4). All positive BAL PCR for Mucor spp. cases had significantly higher chest CT scan scores and spent more time under a ventilator. Conclusions: The identification of COVID-19 with Mucor spp. was observed among 12% (n: 12) of children hospitalized in a COVID-19 ICU. When dealing with pediatric COVID-19 patients, clinicians should consider the differential diagnosis of fungal co-infections and have a low threshold to begin treatment. Moreover, it is highly advisable to take prophylactic measures, such as properly using corticosteroids and shortening the intubation time.Keywords: aspergillosis, COVID-19 identification, mucormycosis, paediatrics
Procedia PDF Downloads 61 Analyzing Electromagnetic and Geometric Characterization of Building Insulation Materials Using the Transient Radar Method (TRM)
Authors: Ali Pourkazemi
Abstract:
The transient radar method (TRM) is one of the non-destructive methods that was introduced by authors a few years ago. The transient radar method can be classified as a wave-based non destructive testing (NDT) method that can be used in a wide frequency range. Nevertheless, it requires a narrow band, ranging from a few GHz to a few THz, depending on the application. As a time-of-flight and real-time method, TRM can measure the electromagnetic properties of the sample under test not only quickly and accurately, but also blindly. This means that it requires no prior knowledge of the sample under test. For multi-layer structures, TRM is not only able to detect changes related to any parameter within the multi-layer structure but can also measure the electromagnetic properties of each layer and its thickness individually. Although the temperature, humidity, and general environmental conditions may affect the sample under test, they do not affect the accuracy of the Blind TRM algorithm. In this paper, the electromagnetic properties as well as the thickness of the individual building insulation materials - as a single-layer structure - are measured experimentally. Finally, the correlation between the reflection coefficients and some other technical parameters such as sound insulation, thermal resistance, thermal conductivity, compressive strength, and density is investigated. The sample to be studied is 30 cm x 50 cm and the thickness of the samples varies from a few millimeters to 6 centimeters. This experiment is performed with both biostatic and differential hardware at 10 GHz. Since it is a narrow-band system, high-speed computation for analysis, free-space application, and real-time sensor, it has a wide range of potential applications, e.g., in the construction industry, rubber industry, piping industry, wind energy industry, automotive industry, biotechnology, food industry, pharmaceuticals, etc. Detection of metallic, plastic pipes wires, etc. through or behind the walls are specific applications for the construction industry.Keywords: transient radar method, blind electromagnetic geometrical parameter extraction technique, ultrafast nondestructive multilayer dielectric structure characterization, electronic measurement systems, illumination, data acquisition performance, submillimeter depth resolution, time-dependent reflected electromagnetic signal blind analysis method, EM signal blind analysis method, time domain reflectometer, microwave, milimeter wave frequencies
Procedia PDF Downloads 69