Search results for: Leszek Chybowski
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5

Search results for: Leszek Chybowski

5 Application of Subversion Analysis in the Search for the Causes of Cracking in a Marine Engine Injector Nozzle

Authors: Leszek Chybowski, Artur Bejger, Katarzyna Gawdzińska

Abstract:

Subversion analysis is a tool used in the TRIZ (Theory of Inventive Problem Solving) methodology. This article introduces the history and describes the process of subversion analysis, as well as function analysis and analysis of the resources, used at the design stage when generating possible undesirable situations. The article charts the course of subversion analysis when applied to a fuel injection nozzle of a marine engine. The work describes the fuel injector nozzle as a technological system and presents principles of analysis for the causes of a cracked tip of the nozzle body. The system is modelled with functional analysis. A search for potential causes of the damage is undertaken and a cause-and-effect analysis for various hypotheses concerning the damage is drawn up. The importance of particular hypotheses is evaluated and the most likely causes of damage identified.

Keywords: complex technical system, fuel injector, function analysis, importance analysis, resource analysis, sabotage analysis, subversion analysis, TRIZ (Theory of Inventive Problem Solving)

Procedia PDF Downloads 576
4 The Key Role of a Bystander Improving the Effectiveness of Cardiopulmonary Resuscitation Performed in Extra-Urban Areas

Authors: Leszek Szpakowski, Daniel Celiński, Sławomir Pilip, Grzegorz Michalak

Abstract:

The aim of the study was to analyse the usefulness of the 'E-rescuer' pilot project planned to be implemented in a chosen area of Eastern Poland in the cases of suspected sudden cardiac arrests in the extra-urban areas. Inventing an application allowing to dispatch simultaneously both Medical Emergency Teams and the E-rescuer to the place of the accident is the crucial assumption of the mentioned pilot project. The E-rescuer is defined to be the trained person able to take effective basic life support and to use automated external defibrillator. Having logged in using a smartphone, the E-rescuer's readiness is reported online to provide cardiopulmonary resuscitation exactly at the given location. Due to the accurately defined location of the E-rescuer, his arrival time is possible to be precisely fixed, and the substantive support through the displayed algorithms is capable of being provided as well. Having analysed the medical records in the years 2015-2016, cardiopulmonary resuscitation was considered to be effective when an early indication of circulation was provided, and the patient was taken to hospital. In the mentioned term, there were 2.291 cases of a sudden cardiac arrest. Cardiopulmonary resuscitation was taken in 621 patients in total including 205 people in the urban area and 416 in the extra-urban areas. The effectiveness of cardiopulmonary resuscitation in the extra-urban areas was much lower (33,8%) than in the urban (50,7%). The average ambulance arrival time was respectively longer in the extra-urban areas, and it was 12,3 minutes while in the urban area 3,3 minutes. There was no significant difference in the average age of studied patients - 62,5 and 64,8 years old. However, the average ambulance arrival time was 7,6 minutes for effective resuscitations and 10,5 minutes for ineffective ones. Hence, the ambulance arrival time is a crucial factor influencing on the effectiveness of cardiopulmonary resuscitation, especially in the extra-urban areas where it is much longer than in the urban. The key role of trained E-rescuers being nearby taking basic life support before the ambulance arrival can effectively support Emergency Medical Services System in Poland.

Keywords: basic life support, bystander, effectiveness, resuscitation

Procedia PDF Downloads 166
3 The Influence of Applying Mechanical Chest Compression Systems on the Effectiveness of Cardiopulmonary Resuscitation in Out-of-Hospital Cardiac Arrest

Authors: Slawomir Pilip, Michal Wasilewski, Daniel Celinski, Leszek Szpakowski, Grzegorz Michalak

Abstract:

The aim of the study was to evaluate the effectiveness of cardiopulmonary resuscitation taken by Medical Emergency Teams (MET) at the place of an accident including the usage of mechanical chest compression systems. In the period of January-May 2017, there were 137 cases of a sudden cardiac arrest in a chosen region of Eastern Poland with 360.000 inhabitants. Medical records and questionnaires filled by METs were analysed to prove the effectiveness of cardiopulmonary resuscitations that were considered to be effective when an early indication of spontaneous circulation was provided and the patient was taken to hospital. A chest compression system used by METs was applied in 60 cases (Lucas3 - 34 patients; Auto Pulse - 24 patients). The effectiveness of cardiopulmonary resuscitation among patients who were employed a chest compression system was much higher (43,3%) than the manual cardiac massage (36,4%). Thus, the usage of Lucas3 chest compression system resulted in 47% while Auto Pulse was 33,3%. The average ambulance arrival time could have had a significant impact on the subsequent effectiveness of cardiopulmonary resuscitation in these cases. Ambulances equipped with Lucas3 reached the destination within 8 minutes, and those with Auto Pulse needed 12,1 minutes. Moreover, taking effective basic life support (BLS) by bystanders before the ambulance arrival was much more frequent for ambulances with Lucas3 than Auto Pulse. Therefore, the percentage of BLS among the group of patients who were employed Lucas3 by METs was 26,5%, and 20,8% for Auto Pulse. The total percentage of taking BLS by bystanders before the ambulance arrival resulted in 25% of patients who were later applied a chest compression system by METs. Not only was shockable cardiac rhythm obtained in 47% of these cases, but an early indication of spontaneous circulation was also provided in all these patients. Both Lucas3 and Auto Pulse were evaluated to be significantly useful in improving the effectiveness of cardiopulmonary resuscitation by 97% of Medical Emergency Teams. Therefore, implementation of chest compression systems essentially makes the cardiopulmonary resuscitation even more effective. The ambulance arrival time, taking successful BLS by bystanders before the ambulance arrival and the presence of shockable cardiac rhythm determine an early indication of spontaneous circulation among patients after a sudden cardiac arrest.

Keywords: cardiac arrest, effectiveness, mechanical chest compression systems, resuscitation

Procedia PDF Downloads 214
2 Study of Mechanical Properties of Large Scale Flexible Silicon Solar Modules on the Various Substrates

Authors: M. Maleczek, Leszek Bogdan, Kazimierz Drabczyk, Agnieszka Iwan

Abstract:

Crystalline silicon (Si) solar cells are the main product in the market among the various photovoltaic technologies concerning such advantages as: material richness, high carrier mobilities, broad spectral absorption range and established technology. However, photovoltaic technology on the stiff substrates are heavier, more fragile and less cost-effective than devices on the flexible substrates to be applied in special applications. The main goal of our work was to incorporate silicon solar cells into various fabric, without any change of the electrical and mechanical parameters of devices. This work is realized for the GEKON project (No. GEKON2/O4/268473/23/2016) sponsored by The National Centre for Research and Development and The National Fund for Environmental Protection and Water Management. In our work, the polyamide or polyester fabrics were used as a flexible substrate in the created devices. Applied fabrics differ in tensile and tear strength. All investigated polyamide fabrics are resistant to weathering and UV, while polyester ones is resistant to ozone, water and ageing. The examined fabrics are tight at 100 cm water per 2 hours. In our work, commercial silicon solar cells with the size 156 × 156 mm were cut into nine parts (called single solar cells) by diamond saw and laser. Gap and edge after cutting of solar cells were checked by transmission electron microscope (TEM) to study morphology and quality of the prepared single solar cells. Modules with the size of 160 × 70 cm (containing about 80 single solar cells) were created and investigated by electrical and mechanical methods. Weight of constructed module is about 1.9 kg. Three types of solar cell architectures such as: -fabric/EVA/Si solar cell/EVA/film for lamination, -backsheet PET/EVA/Si solar cell/EVA/film for lamination, -fabric/EVA/Si solar cell/EVA/tempered glass, were investigated taking into consideration type of fabric and lamination process together with the size of solar cells. In investigated devices EVA, it is ethylene-vinyl acetate, while PET - polyethylene terephthalate. Depend on the lamination process and compatibility of textile with solar cell an efficiency of investigated flexible silicon solar cells was in the range of 9.44-16.64 %. Multi folding and unfolding of flexible module has no impact on its efficiency as was detected by Instron equipment. Power (P) of constructed solar module is 30 W, while voltage about 36 V. Finally, solar panel contains five modules with the polyamide fabric and tempered glass will be produced commercially for different applications (dual use).

Keywords: flexible devices, mechanical properties, silicon solar cells, textiles

Procedia PDF Downloads 141
1 Suicidal Attempts as a Reason for Emergency Medical Teams’ Call-Outs Based on Examples of Ambulance Service in Siedlce, Poland

Authors: Dawid Jakimiuk, Krzysztof Mitura, Leszek Szpakowski, Sławomir Pilip, Daniel Celiński

Abstract:

The Emergency Medical Teams (EMS) of the Ambulance Service in Siedlce serve the population living in the Mazowieckie Voivodeship (the area of eastern Poland with approximately 550,000 inhabitants). They provide health services at the pre-hospital stage to all life-threatening patients. The analysis covered the interventions of emergency medical teams in cases of suicide attempts that occurred in the years 2015-2018. The study was retrospective. The data was obtained on the basis of digital medical records of completed call-outs. When defining the disease entity, the International Statistical Classification of Diseases and Health Problems ICD-10 prepared by WHO was used. The relationship between selected disease entities and the area of EMT intervention, the patient's sex and age, and the time of occurrence of the event were investigated. Non-urban area was defined as the area inhabited by a population below 10,000 residents. Statistical analysis was performed using Pearson's Chi ^ 2 test and presenting the percentage of cases in the study group. Of all the suicide attempts, drug abuse cases were the most frequent, including: X60 (Intentional self-poisoning by and exposure to nonopioid analgesics, antipyretics and antirheumatics); X61 (Intentional self-poisoning by and exposure to antiepileptic, sedative-hypnotic, antiparkinsonian and psychotropic drugs, not elsewhere classified); X62 (Intentional self-poisoning by and exposure to narcotics and psycholeptics [hallucinogens], not elsewhere classified); X63 (Intentional self-poisoning by and exposure to other drugs acting on the autonomic nervous system); X64 (Intentional self-poisoning by and exposure to other and unspecified drugs, medicaments and biological substance) oraz X70 (Intentional self-harm by hanging, strangulation and suffocation). In total, they accounted for 69.4% of all interventions to suicide attempts in the studied period. Statistical analysis shows significant differences (χ2 = 39.30239, p <0.0001, n = 561) between the area of EMT intervention and the type of suicide attempt. In non-urban areas, a higher percentage of X70 diagnoses was recorded (55.67%), while in urban areas, X60-X64 (72.53%). In non-urban areas, a higher proportion of patients attempting suicide was observed compared to patients living in urban areas. For X70 and X60 - X64 in total, the incidence rates in non-urban areas were 80.8% and 56%, respectively. Significant differences were found (χ2 = 119.3304, p <0.0001, n = 561) depending on the method of attempting suicide in relation to the patient's sex. The percentage of women diagnosed with X60-X64 versus X70 was 87.50%, which was the largest number of patients (n = 154) as compared to men. In the case of X70 in relation to X60-X64, the percentage of men was 62.08%, which was the largest number of patients (n = 239) as compared to women (n = 22). In the case of X70, the percentage of men compared to women was as high as 92%. Significant differences were observed (χ2 = 14.94848, p <0.01058) between the hour of EMT intervention and the type of suicide attempt. The highest percentage of X70 occurred between 04:01 - 08:00 (64.44%), while X60-X64 between 00:01 - 04:00 (70.45%). The largest number of cases of all tested suicide attempts was recorded between 16:01 - 20:00 for X70 (n = 62), X60 - X64 (n = 82), respectively. The highest percentage of patients undertaking all suicide attempts studied at work was observed in the age range of 18-30 (31.5%), while the lowest was in the age group over 60 years of age. (11%). There was no significant correlation between the day of the week or individual months of the year and the type of suicide attempt - respectively (χ2 = 6.281729, p <0.39238, n = 561) and (χ2 = 3.348913, p <0.9857, n = 561). There were also no significant differences in the incidence of suicide attempts for each year in the study period (χ2 = 3.348913, p <0.9857 n = 561). The obtained results suggest the necessity to undertake preventive measures in order to minimize the number of suicide attempts. Such activities should be directed especially at young patients living in non-urban areas.

Keywords: emergency med, emergency medical team, attempted suicide, pre-hospital

Procedia PDF Downloads 56