Search results for: Keerthana Gonella
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4

Search results for: Keerthana Gonella

4 Team Members' Perception of Team Leader's Effectiveness in Biotechnology Industry in India

Authors: Keerthana Gonella, Kamesh Apparaju

Abstract:

Teams are all pervasive and team leadership is a much discussed topic in managing projects that characterize the modern work environment. Biotechnology industry in India is an area of research interest for scholars on leadership, especially, team leadership. The present paper examines the perception of team members on the effectiveness of their team leaders in the biotechnology industry in India. This is an empirical study in which the data was collected by administering the closed-ended questionnaire to the respondents from across India. The effectiveness of the team leader is dependent upon his goal orientation that creates a collaborative climate. Leaders with technical know-how inspire teamwork with trust. They build confidence, mitigate the differences and expand team capabilities through teamwork. Effective leaders also create team identity making the most of the differences with a vision.

Keywords: collaboration, perception, team, team capabilities, team leadership

Procedia PDF Downloads 271
3 Electronically Controlled Motorized Steering System (E-Mo Steer)

Authors: M. Prasanth, V. Nithin, R. Keerthana, S.Kalyani

Abstract:

In the current scenario, the steering system in automobiles is such that the motion from the steering wheel is transferred to driving wheel by mechanical linkages. In this paper, we propose a method to design a steering mechanism using servomotors to turn the wheels instead of linkages. In this method, a steering angle sensor senses the turn angle of the steering wheel and its output is processed by an electronical control module. Then the ECM compares the angle value to that of a standard value from a look-up database. Then it gives the appropriate input power and the turning duration to the motors. Correspondingly, the motors turn the wheels by means of bevel gears welded to both the motor output shafts and the wheel hubs. Thus, the wheels are turned without the complicated framework of linkages, reducing the driver’s effort and fatigue considerably.

Keywords: electronic control unit, linkage-less steering, servomotors, E-Mo Steer

Procedia PDF Downloads 238
2 Hand Gesture Interface for PC Control and SMS Notification Using MEMS Sensors

Authors: Keerthana E., Lohithya S., Harshavardhini K. S., Saranya G., Suganthi S.

Abstract:

In an epoch of expanding human-machine interaction, the development of innovative interfaces that bridge the gap between physical gestures and digital control has gained significant momentum. This study introduces a distinct solution that leverages a combination of MEMS (Micro-Electro-Mechanical Systems) sensors, an Arduino Mega microcontroller, and a PC to create a hand gesture interface for PC control and SMS notification. The core of the system is an ADXL335 MEMS accelerometer sensor integrated with an Arduino Mega, which communicates with a PC via a USB cable. The ADXL335 provides real-time acceleration data, which is processed by the Arduino to detect specific hand gestures. These gestures, such as left, right, up, down, or custom patterns, are interpreted by the Arduino, and corresponding actions are triggered. In the context of SMS notifications, when a gesture indicative of a new SMS is recognized, the Arduino relays this information to the PC through the serial connection. The PC application, designed to monitor the Arduino's serial port, displays these SMS notifications in the serial monitor. This study offers an engaging and interactive means of interfacing with a PC by translating hand gestures into meaningful actions, opening up opportunities for intuitive computer control. Furthermore, the integration of SMS notifications adds a practical dimension to the system, notifying users of incoming messages as they interact with their computers. The use of MEMS sensors, Arduino, and serial communication serves as a promising foundation for expanding the capabilities of gesture-based control systems.

Keywords: hand gestures, multiple cables, serial communication, sms notification

Procedia PDF Downloads 11
1 A Descriptive Study on Comparison of Maternal and Perinatal Outcome of Twin Pregnancies Conceived Spontaneously and by Assisted Conception Methods

Authors: Aishvarya Gupta, Keerthana Anand, Sasirekha Rengaraj, Latha Chathurvedula

Abstract:

Introduction: Advances in assisted reproductive technology and increase in the proportion of infertile couples have both contributed to the steep increase in the incidence of twin pregnancies in past decades. Maternal and perinatal complications are higher in twins than in singleton pregnancies. Studies comparing the maternal and perinatal outcomes of ART twin pregnancies versus spontaneously conceived twin pregnancies report heterogeneous results making it unclear whether the complications are due to twin gestation per se or because of assisted reproductive techniques. The present study aims to compare both maternal and perinatal outcomes in twin pregnancies which are spontaneously conceived and after assisted conception methods, so that targeted steps can be undertaken in order to improve maternal and perinatal outcome of twins. Objectives: To study perinatal and maternal outcome in twin pregnancies conceived spontaneously as well as with assisted methods and compare the outcomes between the two groups. Setting: Women delivering at JIPMER (tertiary care institute), Pondicherry. Population: 380 women with twin pregnancies who delivered in JIPMER between June 2015 and March 2017 were included in the study. Methods: The study population was divided into two cohorts – one conceived by spontaneous conception and other by assisted reproductive methods. Association of various maternal and perinatal outcomes with the method of conception was assessed using chi square test or Student's t test as appropriate. Multiple logistic regression analysis was done to assess the independent association of assisted conception with maternal outcomes after adjusting for age, parity and BMI. Multiple logistic regression analysis was done to assess the independent association of assisted conception with perinatal outcomes after adjusting for age, parity, BMI, chorionicity, gestational age at delivery and presence of hypertension or gestational diabetes in the mother. A p value of < 0.05 was considered as significant. Result: There was increased proportion of women with GDM (21% v/s 4.29%) and premature rupture of membranes (35% v/s 22.85%) in the assisted conception group and more anemic women in the spontaneous group (71.27% v/s 55.1%). However assisted conception per se increased the incidence of GDM among twin gestations (OR 3.39, 95% CI 1.34 – 8.61) and did not influence any of the other maternal outcomes. Among the perinatal outcomes, assisted conception per se increased the risk of having very preterm (<32 weeks) neonates (OR 3.013, 95% CI 1.432 – 6.337). The mean birth weight did not significantly differ between the two groups (p = 0.429). Though there were higher proportion of babies admitted to NICU in the assisted conception group (48.48% v/s 36.43%), assisted conception per se did not increase the risk of admission to NICU (OR 1.23, 95% CI 0.76 – 1.98). There was no significant difference in perinatal mortality rates between the two groups (p = 0.829). Conclusion: Assisted conception per se increases the risk of developing GDM in women with twin gestation and increases the risk of delivering very preterm babies. Hence measures should be taken to ensure appropriate screening methods for GDM and suitable neonatal care in such pregnancies.

Keywords: assisted conception, maternal outcomes, perinatal outcomes, twin gestation

Procedia PDF Downloads 169