Search results for: Kazuto Matsumoto
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 11

Search results for: Kazuto Matsumoto

11 Improved Network Construction Methods Based on Virtual Rails for Mobile Sensor Network

Authors: Noritaka Shigei, Kazuto Matsumoto, Yoshiki Nakashima, Hiromi Miyajima

Abstract:

Although Mobile Wireless Sensor Networks (MWSNs), which consist of mobile sensor nodes (MSNs), can cover a wide range of observation region by using a small number of sensor nodes, they need to construct a network to collect the sensing data on the base station by moving the MSNs. As an effective method, the network construction method based on Virtual Rails (VRs), which is referred to as VR method, has been proposed. In this paper, we propose two types of effective techniques for the VR method. They can prolong the operation time of the network, which is limited by the battery capabilities of MSNs and the energy consumption of MSNs. The first technique, an effective arrangement of VRs, almost equalizes the number of MSNs belonging to each VR. The second technique, an adaptive movement method of MSNs, takes into account the residual energy of battery. In the simulation, we demonstrate that each technique can improve the network lifetime and the combination of both techniques is the most effective.

Keywords: mobile sensor node, relay of sensing data, residual energy, virtual rail, wireless sensor network

Procedia PDF Downloads 303
10 A Quantification Method of Attractiveness of Stations and an Estimation Method of Number of Passengers Taking into Consideration the Attractiveness of the Station

Authors: Naoya Ozaki, Takuya Watanabe, Ryosuke Matsumoto, Noriko Fukasawa

Abstract:

In the metropolitan areas in Japan, in many stations, shopping areas are set up, and escalators and elevators are installed to make the stations be barrier-free. Further, many areas around the stations are being redeveloped. Railway business operators want to know how much effect these circumstances have on attractiveness of the station or number of passengers using the station. So, we performed a questionnaire survey of the station users in the metropolitan areas for finding factors to affect the attractiveness of stations. Then, based on the analysis of the survey, we developed a method to quantitatively evaluate attractiveness of the stations. We also developed an estimation method for number of passengers based on combination of attractiveness of the station quantitatively evaluated and the residential and labor population around the station. Then, we derived precise linear regression models estimating the attractiveness of the station and number of passengers of the station.

Keywords: attractiveness of the station, estimation method, number of passengers of the station, redevelopment around the station, renovation of the station

Procedia PDF Downloads 255
9 Basic Characteristics of Synchronized Stir Welding and Its Prospects

Authors: Ipei Sato, Naonori Shibata, Shoji Matsumoto, Naruhito Matsumoto

Abstract:

Friction stir welding (FSW) has been widely used in the automotive, aerospace, and high-tech industries due to its superiority in mechanical properties after joining. In order to achieve a good quality joint by friction stir welding (FSW), it is necessary to secure an advanced angle (usually 3 to 5 degrees) using a dedicated FSW machine and to join on a highly rigid machine. On the other hand, although recently, a new combined machine that combines the cutting function of a conventional machining center with the FSW function has appeared on the market, its joining process window is small, so joining defects easily occur, and it lacks reproducibility, which limits its application to the automotive industry, where control accuracy is required. This has limited the use of FSW machines in the automotive industry, where control accuracy is required. FSW-only machines or hybrid equipment that combines FSW and cutting machines require high capital investment costs, which is one of the reasons why FSW itself has not penetrated the market. Synchronized stir welding, a next-generation joining technology developed by our company, requires no tilt angle and is a very cost-effective method of welding. It is a next-generation joining technology that does not require a tilt angle, does not require a complicated spindle mechanism, and minimizes the load and vibration on the spindle, temperature during joining, and shoulder diameter, thereby enabling a wide range of joining conditions and high-strength, high-speed joining with no joining defects. In synchronized stir welding, the tip of the joining tool is "driven by microwaves" in both the rotational and vertical directions of the tool. The tool is synchronized and stirred in the direction and at the speed required by the material to be stirred in response to the movement required by the material to be welded, enabling welding that exceeds conventional concepts. Conventional FSW is passively stirred by an external driving force, resulting in low joining speeds and high heat input due to the need for a large shoulder diameter. In contrast, SSW is characterized by the fact that materials are actively stirred in synchronization with the direction and speed in which they are to be stirred, resulting in a high joining speed and a small shoulder diameter, which allows joining to be completed with low heat input. The advantages of synchronized stir welding technology in terms of basic mechanical properties are described. The superiority of the basic mechanical properties of SSW over FSW was evaluated as a comparison of the strength of the joint cross section in the comparison between FSW and SSW. SSW, compared to FSW, has tensile strength; base metal 242 MPa/217 MPa after FSW 89%, base metal 242 MPa/225 MPa after SSW 93%. Vickers hardness; base metal 75.0HV/FSW; 57.5HV 76% SSW; 66.0HV 88% (weld center), showing excellent results. In the tensile test, the material used was aluminum (A5052-H112) plate 5 mm thick, and the specimen was dumbbell-shaped, 2 mm thick, 4 mm wide, and 60 mm long. Measurements were made at a loading speed of 20%/min (in accordance with Z 2241:2022). Tensile testing machine: INSTRON Japan, model: INSTRON 5982. Vickers hardness was measured on a 5 mm thick specimen of A5052 tempered H112 with a width of 15 mm at 0.3 pitch (in accordance with JIS Z 2244:2020). Vickers tester: FUTURE-TECH Model: FM-300.

Keywords: FSW, SSW, synchronized stir welding, requires no tilt angles, running peak temperature less than 100 degrees C

Procedia PDF Downloads 17
8 Quality of So-Called Organic Fertilizers in Vietnam's Market

Authors: Hoang Thi Quynh, Shima Kazuto

Abstract:

Organic farming is gaining interest in Vietnam. However, organic fertilizer production is not sufficiently regulated, resulting in unknown quality. This study investigated characteristics of so-called organic fertilizers in the Vietnam’s market and their mineralization in soil-plant system. We collected 15 commercial products (11 domestic and 4 imported) which labelled 'organic fertilizer' in the market to analyze nutrients composition. A 20 day-incubation experiment was carried on with 80 g sandy-textured soil, amended with the fertilizer at a rate of 109.4 mgN.kg⁻¹soil in 150 mL glass bottle at 25℃. We categorized them according to nutrients content and mineralization rate, and then selected 8 samples for cultivation experiment. The experiment was conducted by growing Komatsuna (Brassica campestris) in sandy-textured soil using an automatic watering apparatus in a greenhouse. The fertilizers were applied to the top one-third of the soil stratum at a rate of 200 mgN.kg⁻¹ soil. Our study also analyzed material flow of coffee husk compost in Central Highland of Vietnam. Total N, P, K, Ca, Mg and C: N ratio varied greatly cross the domestic products, whereas they were quite similar among the imported materials. The proportion of inorganic-N to T-N of domestic products was higher than 25% in 8 of 11 samples. These indicate that N concentration increased dramatically in most domestic products compared with their raw materials. Additionally, most domestic products contained less P, and their proportions of Truog-P to T-P were greatly different. These imply that some manufactures were interested in adjusting P concentration, but some ones were not. Furthermore, the compost was made by mixing with chemical substances to increase nutrients content (N, P), and also added construction surplus soil to gain weight before packing product to sell in the market as 'organic fertilizer'. There was a negative correlation between C:N ratio and mineralization rate of the fertilizers. There was a significant difference in N efficiency among the fertilizer treatments. N efficiency of most domestic products was higher than chemical fertilizer and imported organic fertilizers. These results suggest regulations on organic fertilizers production needed to support organic farming that is based on internationally accepted standards in Vietnam.

Keywords: inorganic N, mineralization, N efficiency, so-called organic fertilizers, Vietnam’s market

Procedia PDF Downloads 145
7 Changes of pH and Pseudomonas Aeruginosa Growth in Liquid Media

Authors: Sayaka Ono, Ryutaro Imai, Tomoko Ehara, Tetsuya Matsumoto, Hajime Matsumura

Abstract:

Background: Wound pH affects a number of important factors in wound healing. We previously measured the pH value of the exudates collected from second-degree burns and found that the increase in pH was observed in the burn wounds in which colonized by Staphylococcus spp., and the increase in pH was evident prior to the clinical findings of local infection. To investigate the relationship between the changes of pH value and bacterial growth, we performed in vitro study using Pseudomonas aeruginosa and liquid medium as a locally infected wound equivalent model. Methods: Pseudomonas aeruginosa standard strain (ATCCR 10145TM) was cultured at 37 °C environment in Luria Broth Miller medium. The absorbance rate which means the amount of bacteria was measured by a microplate reader 2300EnSpireTM). The pH was measured using pH-indicator strips (MColorpHastTM). The statistical analysis was performed using the product-moment correlation coefficient of Pearson's. Results: The absorbance rate and pH value were increased along with culture period. There was a positive correlation between pH value and absorbance rate (n = 27, Pearson's r = 0.985). Moreover, there was a positive correlation between pH value and the culture period (n = 18, Pearson's r = 0.901). The bacteria was well growth in the media from pH 6.6 to pH 8.0 and the pH of culture media converged at 8 -9 along with the bacterial growth. Conclusion: From these results, we conclude that pH value of the wound is correlated with the number of viable bacteria and bacterial growth periods.

Keywords: colonization, potential of hydrogen, Pseudomonas aeruginosa, wound

Procedia PDF Downloads 240
6 A Linear Regression Model for Estimating Anxiety Index Using Wide Area Frontal Lobe Brain Blood Volume

Authors: Takashi Kaburagi, Masashi Takenaka, Yosuke Kurihara, Takashi Matsumoto

Abstract:

Major depressive disorder (MDD) is one of the most common mental illnesses today. It is believed to be caused by a combination of several factors, including stress. Stress can be quantitatively evaluated using the State-Trait Anxiety Inventory (STAI), one of the best indices to evaluate anxiety. Although STAI scores are widely used in applications ranging from clinical diagnosis to basic research, the scores are calculated based on a self-reported questionnaire. An objective evaluation is required because the subject may intentionally change his/her answers if multiple tests are carried out. In this article, we present a modified index called the “multi-channel Laterality Index at Rest (mc-LIR)” by recording the brain activity from a wider area of the frontal lobe using multi-channel functional near-infrared spectroscopy (fNIRS). The presented index aims to measure multiple positions near the Fpz defined by the international 10-20 system positioning. Using 24 subjects, the dependencies on the number of measuring points used to calculate the mc-LIR and its correlation coefficients with the STAI scores are reported. Furthermore, a simple linear regression was performed to estimate the STAI scores from mc-LIR. The cross-validation error is also reported. The experimental results show that using multiple positions near the Fpz will improve the correlation coefficients and estimation than those using only two positions.

Keywords: frontal lobe, functional near-infrared spectroscopy, state-trait anxiety inventory score, stress

Procedia PDF Downloads 217
5 Relationship-Centred Care in Cross-Linguistic Medical Encounters

Authors: Nami Matsumoto

Abstract:

This study explores the experiences of cross-linguistic medical encounters by patients, and their views of receiving language support therein, with a particular focus on Japanese-English cases. The aim of this study is to investigate the reason for the frequent use of a spouse as a communication mediator from a Japanese perspective, through a comparison with that of English speakers. This study conducts an empirical qualitative analysis of the accounts of informants. A total of 31 informants who have experienced Japanese-English cross-linguistic medical encounters were recruited in Australia and Japan for semi-structured in-depth interviews. A breakdown of informants is 15 English speakers and 16 Japanese speakers. In order to obtain a further insight into collected data, additional interviews were held with 4 Australian doctors who are familiar with using interpreters. This study was approved by the Australian National University Human Research Ethics Committee, and written consent to participate in this study was obtained from all participants. The interviews lasted up to over one hour. They were audio-recorded and subsequently transcribed by the author. Japanese transcriptions were translated into English by the author. An analysis of interview data found that patients value relationship in communication. Particularly, Japanese informants, who have an English-speaking spouse, value trust-based communication interventions by their spouse, regardless of the language proficiency of the spouse. In Australia, health care interpreters are required to abide by the national code of ethics for interpreters. The Code defines the role of an interpreter exclusively to be language rendition and enshrines the tenets of accuracy, confidentiality and professional role boundaries. However, the analysis found that an interpreter who strictly complies with the Code sometimes fails to render the real intentions of the patient and their doctor. Findings from the study suggest that an interpreter should not be detached from the context and should be more engaged in the needs of patients. Their needs are not always communicated by an interpreter when they simply follow a professional code of ethics. The concept of relationship-centred care should be incorporated in the professional practice of health care interpreters.

Keywords: health care, Japanese-English medical encounters, language barriers, trust

Procedia PDF Downloads 227
4 Thoughts Regarding Interprofessional Work between Nurses and Speech-Language-Hearing Therapists in Cancer Rehabilitation: An Approach for Dysphagia

Authors: Akemi Nasu, Keiko Matsumoto

Abstract:

Rehabilitation for cancer requires setting up individual goals for each patient and an approach that properly fits the stage of cancer when putting into practice. In order to cope with the daily changes in the patients' condition, the establishment of a good cooperative relationship between the nurses and the physiotherapists, occupational therapists, and speech-language-hearing therapists (therapists) becomes essential. This study will focus on the present situation of the cooperation between nurses and therapists, especially the speech-language-hearing therapists, and aim to elucidate what develops there. A semi-structured interview was conducted targeted at a physical therapist having practical experience in working in collaboration with nurses. The contents of the interview were transcribed and converted to data, and the data was encoded and categorized with sequentially increasing degrees of abstraction to conduct a qualitative explorative factor analysis of the data. When providing ethical explanations, particular care was taken to ensure that participants would not be subjected to any disadvantages as a result of participating in the study. In addition, they were also informed that their privacy would be ensured and that they have the right to decline to participate in the study. In addition, they were also informed that the results of the study would be announced publicly at an applicable nursing academic conference. This study has been approved following application to the ethical committee of the university with which the researchers are affiliated. The survey participant is a female speech-language-hearing therapist in her forties. As a result of the analysis, 6 categories were extracted consisting of 'measures to address appetite and aspiration pneumonia prevention', 'limitation of the care a therapist alone could provide', 'the all-inclusive patient- supportive care provided by nurses', 'expand the beneficial cooperation with nurses', 'providing education for nurses on the swallowing function utilizing videofluoroscopic examination of swallowing', 'enhancement of communication including conferences'. In order to improve the team performance, and for the teamwork competency necessary for the provision of safer care, mutual support is essential. As for the cooperation between nurses and therapists, this survey indicates that the maturing of the cooperation between professionals in order to improve nursing professionals' knowledge and enhance communication will lead to an improvement in the quality of the rehabilitation for cancer.

Keywords: cancer rehabilitation, nurses, speech-language-hearing therapists, interprofessional work

Procedia PDF Downloads 108
3 Electromagnetic-Mechanical Stimulation on PC12 for Enhancement of Nerve Axonal Extension

Authors: E. Nakamachi, K. Matsumoto, K. Yamamoto, Y. Morita, H. Sakamoto

Abstract:

In recently, electromagnetic and mechanical stimulations have been recognized as the effective extracellular environment stimulation technique to enhance the defected peripheral nerve tissue regeneration. In this study, we developed a new hybrid bioreactor by adopting 50 Hz uniform alternative current (AC) magnetic stimulation and 4% strain mechanical stimulation. The guide tube for nerve regeneration is mesh structured tube made of biodegradable polymer, such as polylatic acid (PLA). However, when neural damage is large, there is a possibility that peripheral nerve undergoes necrosis. So it is quite important to accelerate the nerve tissue regeneration by achieving enhancement of nerve axonal extension rate. Therefore, we try to design and fabricate the system that can simultaneously load the uniform AC magnetic field stimulation and the stretch stimulation to cells for enhancement of nerve axonal extension. Next, we evaluated systems performance and the effectiveness of each stimulation for rat adrenal pheochromocytoma cells (PC12). First, we designed and fabricated the uniform AC magnetic field system and the stretch stimulation system. For the AC magnetic stimulation system, we focused on the use of pole piece structure to carry out in-situ microscopic observation. We designed an optimum pole piece structure using the magnetic field finite element analyses and the response surface methodology. We fabricated the uniform AC magnetic field stimulation system as a bio-reactor by adopting analytically determined design specifications. We measured magnetic flux density that is generated by the uniform AC magnetic field stimulation system. We confirmed that measurement values show good agreement with analytical results, where the uniform magnetic field was observed. Second, we fabricated the cyclic stretch stimulation device under the conditions of particular strains, where the chamber was made of polyoxymethylene (POM). We measured strains in the PC12 cell culture region to confirm the uniform strain. We found slightly different values from the target strain. Finally, we concluded that these differences were allowable in this mechanical stimulation system. We evaluated the effectiveness of each stimulation to enhance the nerve axonal extension using PC12. We confirmed that the average axonal extension length of PC12 under the uniform AC magnetic stimulation was increased by 16 % at 96 h in our bio-reactor. We could not confirm that the axonal extension enhancement under the stretch stimulation condition, where we found the exfoliating of cells. Further, the hybrid stimulation enhanced the axonal extension. Because the magnetic stimulation inhibits the exfoliating of cells. Finally, we concluded that the enhancement of PC12 axonal extension is due to the magnetic stimulation rather than the mechanical stimulation. Finally, we confirmed that the effectiveness of the uniform AC magnetic field stimulation for the nerve axonal extension using PC12 cells.

Keywords: nerve cell PC12, axonal extension, nerve regeneration, electromagnetic-mechanical stimulation, bioreactor

Procedia PDF Downloads 229
2 The Effect of Vibration Amplitude on Tissue Temperature and Lesion Size When Using a Vibrating Cardiac Catheter

Authors: Kaihong Yu, Tetsui Yamashita, Shigeaki Shingyochi, Kazuo Matsumoto, Makoto Ohta

Abstract:

During cardiac ablation, high power delivery for deeper lesion formation is limited by electrode-tissue interface overheating which can cause serious complications such as thrombus. To prevent this overheating, temperature control and open irrigation are often used. In temperature control, radiofrequency generator is adjusted to deliver the maximum output power, which maintains the electrode temperature at a target temperature (commonly 55°C or 60°C). Then the electrode-tissue interface temperature is also limited. The electrode temperature is a result of heating from the contacted tissue and cooling from the surrounding blood. Because the cooling from blood is decreased under conditions of low blood flow, the generator needs to decrease the output power. Thus, temperature control cannot deliver high power under conditions of low blood flow. In open irrigation, saline in room temperature is flushed through the holes arranged in the electrode. The electrode-tissue interface is cooled by the sufficient environmental cooling. And high power delivery can also be done under conditions of low blood flow. However, a large amount of saline infusions (approximately 1500 ml) during irrigation can cause other serious complication. When open irrigation cannot be used under conditions of low blood flow, a new overheating prevention may be required. The authors have proposed a new electrode cooling method by making the catheter vibrating. The previous work has introduced that the vibration can make a cooling effect on electrode, which may result form that the vibration could increase the flow velocity around the catheter. The previous work has also proved that increasing vibration frequency can increase the cooling by vibration. However, the effect of the vibration amplitude is still unknown. Thus, the present study investigated the effect of vibration amplitude on tissue temperature and lesion size. An agar phantom model was used as a tissue-equivalent material for measuring tissue temperature. Thermocouples were inserted into the agar to measure the internal temperature. Porcine myocardium was used for lesion size measurement. A normal ablation catheter was set perpendicular to the tissue (agar or porcine myocardium) with 10 gf contact force in 37°C saline without flow. Vibration amplitude of ± 0.5, ± 0.75, and ± 1.0 mm with a constant frequency (31 Hz or 63) was used. A temperature control protocol (45°C for agar phantom, 60°C for porcine myocardium) was used for the radiofrequency applications. The larger amplitude shows the larger lesion sizes. And the higher tissue temperatures in agar phantom are also shown with the higher amplitude. With a same frequency, the larger amplitude has the higher vibrating speed. And the higher vibrating speed will increase the flow velocity around the electrode more, which leads to a larger electrode temperature decrease. To maintain the electrode at the target temperature, ablator has to increase the output power. With the higher output power in the same duration, the released energy also increases. Consequently, the tissue temperature will be increased and lead to larger lesion sizes.

Keywords: cardiac ablation, electrode cooling, lesion size, tissue temperature

Procedia PDF Downloads 343
1 Brief Cognitive Behavior Therapy (BCBT) in a Japanese School Setting: Preliminary Outcomes on a Single Arm Study

Authors: Yuki Matsumoto, Yuma Ishimoto

Abstract:

Cognitive Behavior Therapy (CBT) with children has shown effective application to various problems such as anxiety and depression. Although there are barriers to access to mental health services including lack of professional services in communities and parental concerns about stigma, school has a significant role to address children’s health problems. Schools are regarded as a suitable arena for prevention and early intervention of mental health problems. In this line, CBT can be adaptable to school education and useful to enhance students’ social and emotional skills. However, Japanese school curriculum is rigorous so as to limit available time for implementation of CBT in schools. This paper describes Brief Cognitive Behavior Therapy (BCBT) with children in a Japanese school setting. The program has been developed in order to facilitate acceptability of CBT in schools and aimed to enhance students’ skills to manage anxiety and difficult behaviors. The present research used a single arm design in which 30 students aged 9-10 years old participated. The authors provided teachers a CBT training workshop (two hours) at two primary schools in Tokyo metropolitan area and recruited participants in the research. A homeroom teacher voluntarily delivered a 6-session BCBT program (15 minutes each) in classroom periods which is called as Kaerinokai, a meeting before leaving school. Students completed a questionnaire sheet at pre- and post-periods under the supervision of the teacher. The sheet included the Spence Child Anxiety Scale (SCAS), the Depression Self-Rating Scale for Children (DSRS), and the Strengths and Difficulties Questionnaire (SDQ). The teacher was asked for feedback after the completion. Significant positive changes were found in the total and five of six sub-scales of the SCAS and the total difficulty scale of the SDQ. However, no significant changes were seen in Physical Injury Fear sub-scale of the SCAS, in the DSRS or the Prosocial sub-scale of the SDQ. The effect sizes are mostly between small and medium. The teacher commented that the program was easy to use and found positive changes in classroom activities and personal relationships. This preliminary research showed the feasibility of the BCBT in a school setting. The results suggest that the BCBT offers effective treatment for reduction in anxiety and in difficult behaviors. There is a good prospect of the BCBT suggesting that BCBT may be easier to be delivered than CBT by Japanese teachers to promote child mental health. The study has limitations including no control group, small sample size, or a short teacher training. Future research should address these limitations.

Keywords: brief cognitive behavior therapy, cognitive behavior therapy, mental health services in schools, teacher training workshop

Procedia PDF Downloads 303