Search results for: Emi Ohta
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5

Search results for: Emi Ohta

5 Inhibition of Sea Urchin and Starfish Embryonic Development by Hexane Extracts from Five Philippine Marine Sponges

Authors: Chona Gelani, Mylene Uy, Keisuke Yasuda, Emi Ohta, Shinji Ohta

Abstract:

The marine environment is undoubtedly a rich source of diverse organisms that possess bioactive secondary metabolites with important pharmacological activities. Marine sponges have since been contributing a wide array of compounds of biomedical and pharmaceutical importance. This study is an attempt to contribute to the growing and advancing marine natural products research. It aims to evaluate the cytotoxicity of the hexane extract (H) from the Philippine marine sponges, Rhabdastrella globostellata (Rg), Callyspongia sp. (Calsp), Callyspongia aerizusa (Ca), Carteriospongia sp. (Carsp), and Cinachyrella sp. (Cisp) using the eggs of starfish, Asterina pectinifera, and sea urchin, Hemicentrotus pulcherrimus. Specifically, the cytotoxicity of the marine sponge hexane extract was determined through its inhibition of starfish and sea urchin embryonic development. After 24 hours, CarspH and RgH inhibited early gastrulation of sea urchin at a minimum concentration of 15.63 and 31.25 μg/mL, respectively. CalspH inhibited the early gastrulation of both sea urchin and starfish at 125 μg/mL, whereas CaH halted the morula of sea urchin and early gastrulation of starfish at 250 μg/mL. CispH exhibited relatively weak inhibitory activity on starfish embryogenesis but inhibited the early gastrulation of sea urchin at 250 μg/mL. The results obtained from this study were used as basis for the separation, isolation and purification of the component(s) of the hexane extracts from the five Philippine marine sponges.

Keywords: embryonic development, marine sponge cytotoxicity, Philippine marine sponges, sea urchin and starfish embryogenesis

Procedia PDF Downloads 281
4 On Developing a Core Guideline for English Language Training Programs in Business Settings

Authors: T. Ito, K. Kawaguchi, R. Ohta

Abstract:

The purpose of this study is to provide a guideline to assist globally-minded companies in developing task-based English-language programs for their employees. After conducting an online self-assessment questionnaire comprised of 45 job-related tasks, we analyzed responses received from 3,000 Japanese company employees and developed a checklist that considered three areas: (i) the percentage of those who need to accomplish English-language tasks in their workplace (need for English), (ii) a five-point self-assessment score (task performance level), and (iii) the impact of previous task experience on perceived performance (experience factor). The 45 tasks were graded according to five proficiency levels. Our results helped us to create a core guideline that may assist companies in two ways: first, in helping determine which tasks employees with a certain English proficiency should be able to satisfactorily carry out, and secondly, to quickly prioritize which business-related English skills they would need in future English language programs.

Keywords: business settings, can-do statements, English language training programs, self-assessment, task experience

Procedia PDF Downloads 250
3 The Effect of Vibration Amplitude on Tissue Temperature and Lesion Size When Using a Vibrating Cardiac Catheter

Authors: Kaihong Yu, Tetsui Yamashita, Shigeaki Shingyochi, Kazuo Matsumoto, Makoto Ohta

Abstract:

During cardiac ablation, high power delivery for deeper lesion formation is limited by electrode-tissue interface overheating which can cause serious complications such as thrombus. To prevent this overheating, temperature control and open irrigation are often used. In temperature control, radiofrequency generator is adjusted to deliver the maximum output power, which maintains the electrode temperature at a target temperature (commonly 55°C or 60°C). Then the electrode-tissue interface temperature is also limited. The electrode temperature is a result of heating from the contacted tissue and cooling from the surrounding blood. Because the cooling from blood is decreased under conditions of low blood flow, the generator needs to decrease the output power. Thus, temperature control cannot deliver high power under conditions of low blood flow. In open irrigation, saline in room temperature is flushed through the holes arranged in the electrode. The electrode-tissue interface is cooled by the sufficient environmental cooling. And high power delivery can also be done under conditions of low blood flow. However, a large amount of saline infusions (approximately 1500 ml) during irrigation can cause other serious complication. When open irrigation cannot be used under conditions of low blood flow, a new overheating prevention may be required. The authors have proposed a new electrode cooling method by making the catheter vibrating. The previous work has introduced that the vibration can make a cooling effect on electrode, which may result form that the vibration could increase the flow velocity around the catheter. The previous work has also proved that increasing vibration frequency can increase the cooling by vibration. However, the effect of the vibration amplitude is still unknown. Thus, the present study investigated the effect of vibration amplitude on tissue temperature and lesion size. An agar phantom model was used as a tissue-equivalent material for measuring tissue temperature. Thermocouples were inserted into the agar to measure the internal temperature. Porcine myocardium was used for lesion size measurement. A normal ablation catheter was set perpendicular to the tissue (agar or porcine myocardium) with 10 gf contact force in 37°C saline without flow. Vibration amplitude of ± 0.5, ± 0.75, and ± 1.0 mm with a constant frequency (31 Hz or 63) was used. A temperature control protocol (45°C for agar phantom, 60°C for porcine myocardium) was used for the radiofrequency applications. The larger amplitude shows the larger lesion sizes. And the higher tissue temperatures in agar phantom are also shown with the higher amplitude. With a same frequency, the larger amplitude has the higher vibrating speed. And the higher vibrating speed will increase the flow velocity around the electrode more, which leads to a larger electrode temperature decrease. To maintain the electrode at the target temperature, ablator has to increase the output power. With the higher output power in the same duration, the released energy also increases. Consequently, the tissue temperature will be increased and lead to larger lesion sizes.

Keywords: cardiac ablation, electrode cooling, lesion size, tissue temperature

Procedia PDF Downloads 371
2 Fire Safe Medical Oxygen Delivery for Aerospace Environments

Authors: M. A. Rahman, A. T. Ohta, H. V. Trinh, J. Hyvl

Abstract:

Atmospheric pressure and oxygen (O2) concentration are critical life support parameters for human-occupied aerospace vehicles and habitats. Various medical conditions may require medical O2; for example, the American Medical Association has determined that commercial air travel exposes passengers to altitude-related hypoxia and gas expansion. It may cause some passengers to experience significant symptoms and medical complications during the flight, requiring supplemental medical-grade O2 to maintain adequate tissue oxygenation and prevent hypoxemic complications. Although supplemental medical grade O2 is a successful lifesaver for respiratory and cardiac failure, O2-enriched exhaled air can contain more than 95 % O2, increasing the likelihood of a fire. In an aerospace environment, a localized high concentration O2 bubble forms around a patient being treated for hypoxia, increasing the cabin O2 beyond the safe limit. To address this problem, this work describes a medical O2 delivery system that can reduce the O2 concentration from patient-exhaled O2-rich air to safe levels while maintaining the prescribed O2 administration to the patient. The O2 delivery system is designed to be a part of the medical O2 kit. The system uses cationic multimetallic cobalt complexes to reversibly, selectively, and stoichiometrically chemisorb O2 from the exhaled air. An air-release sub-system monitors the exhaled air, and as soon the O2 percentage falls below 21%, the air is released to the room air. The O2-enriched exhaled air is channeled through a layer of porous, thin-film heaters coated with the cobalt complex. The complex absorbs O2, and when saturated, the complex is heated to 100°C using the thin-film heater. Upon heating, the complex desorbs O2 and is once again ready to absorb or remove the excess O2 from exhaled air. The O2 absorption is a sub-second process, and desorption is a multi-second process. While heating at 0.685 °C/sec, the complex desorbs ~90% O2 in 110 sec. These fast reaction times mean that a simultaneous absorb/desorb process in the O2 delivery system will create a continuous absorption of O2. Moreover, the complex can concentrate O2 by a factor of 160 times that in air and desorb over 90% of the O2 at 100°C. Over 12 cycles of thermogravimetry measurement, less than 0.1% decrease in reversibility in O2 uptake was observed. The 1 kg complex can desorb over 20L of O2, so simultaneous O2 desorption by 0.5 kg of complex and absorption by 0.5 kg of complex can potentially continuously remove 9L/min O2 (~90% desorbed at 100°C) from exhaled air. The complex is synthesized and characterized for reversible O2 absorption and efficacy. The complex changes its color from dark brown to light gray after O2 desorption. In addition to thermogravimetric analysis, the O2 absorption/desorption cycle is characterized using optical imaging, showing stable color changes over ten cycles. The complex was also tested at room temperature in a low O2 environment in its O2 desorbed state, and observed to hold the deoxygenated state under these conditions. The results show the feasibility of using the complex for reversible O2 absorption in the proposed fire safe medical O2 delivery system.

Keywords: fire risk, medical oxygen, oxygen removal, reversible absorption

Procedia PDF Downloads 103
1 External Program Evaluation: Impacts and Changes on Government-Assisted Refugee Mothers

Authors: Akiko Ohta, Masahiro Minami, Yusra Qadir, Jennifer York

Abstract:

The Home Instruction for Parents of Preschool Youngsters (HIPPY) is a home instruction program for mothers of children 3 to 5 years old. Using role-play as a method of teaching, the participating mothers work with their home visitors and learn how to deliver the HIPPY curriculum to their children. Applying HIPPY, Reviving Hope and Home for High-risk Refugee Mothers Program (RHH) was created to provide more personalized peer support and to respond to ongoing settlement challenges for isolated and vulnerable Government Assisted Refugee (GAR) mothers. GARs often have greater needs and vulnerabilities than other refugee groups. While the support is available, they often face various challenges and barriers in starting their new lives in Canada, such as inadequate housing, low first-language literacy levels, low competency in English or French, and social isolation. The pilot project was operated by Mothers Matter Centre (MMC) from January 2019 to March 2021 in partnership with the Immigrant Services Society of BC (ISSofBC). The formative evaluation was conducted by a research team at Simon Fraser University. In order to provide more suitable support for GAR mothers, RHH intended to offer more flexibility in HIPPY delivery, supported by a home visitor, to meet the need of refugee mothers facing various conditions and challenges; to have a pool of financial resources to be used for the RHH families when necessitated during the program period; to have another designated staff member, called a community navigator, assigned to facilitate the support system for the RHH families in their settlement; to have a portable device available for each RHH mother to navigate settlement support resources; and to provide other variations of the HIPPY curriculum as an option for the RHH mothers, including a curriculum targeting pre-HIPPY age children. Reflections on each program component was collected from RHH mothers and staff members of MMC and ISSofBC, including frontline workers and management staff, through individual interviews and focus group discussions. Each of the RHH program components was analyzed and evaluated by applying Moore’s four domains framework to identify key information and generate new knowledge (data). To capture RHH mothers’ program experience more in depth based on their own reflections, the photovoice method was used. Some photos taken by the mothers will be shared to illustrate their RHH experience as part of their life stories. Over the period of the program, this evaluation observed how RHH mothers became more confident in various domains, such as communicating with others, taking public transportations alone, and teaching their own child(ren). One of the major factors behind the success was their home visitors’ flexibility and creativity to create a more meaningful and tailored approach for each mother, depending on her background and personal situation. The role of the community navigator was tested out and improved during the program period. The community navigators took the key role to assess the needs of the RHH families and connect them with community resources. Both the home visitors and community navigators were immigrant mothers themselves and owing to their dedicated care for the RHH mothers; they were able to gain trust and work closely and efficiently with RHH mothers.

Keywords: refugee mothers, settlement support, program evaluation, Canada

Procedia PDF Downloads 171