Search results for: Debjyoti Bhakat
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4

Search results for: Debjyoti Bhakat

4 Characterization of Enterotoxigenic Escherichia coli CS6 Promoter

Authors: Mondal Indranil, Bhakat Debjyoti, Mukhopadayay Asish K., Chatterjee Nabendu S.

Abstract:

CS6 is the prevalent CF in our region and deciphering its molecular regulators would play a pivotal role in reducing the burden of ETEC pathogenesis. In prokaryotes, most of the genes are under the control of one operon and the promoter present upstream of the gene regulates the transcription of that gene. Here the promoter of CS6 was characterized by computational method and further analyzed by β-galactosidase assay and sequencing. Promoter constructs and deletions were prepared as required to analyze promoter activity. The effect of different additives on the CS6 promoter was analysed by the β-galactosidase assay. Bioinformatics analysis done by Softberry/BPROM predicted fur, lrp, and crp boxes, -10 and -35 region upstream of the CS6 gene. The promoter construction in no promoter plasmid pTL61T showed that region -573 to +1 is actually the promoter region as predicted. Sequential deletion of the region upstream of CS6 revealed that promoter activity remains the same when -573bp to -350bp is deleted. But after the deletion of the upstream region -350 bp to -255bp, promoter expression decreases drastically to 26%. Further deletion also decreases promoter activity up to a little range. So the region -355bp to -255bp holds the promoter sequence for the CS6 gene. Additives like iron, NaCl, etc., modulate promoter activity in a dose-dependent manner. From the promoter analysis, it can be said that the minimum region lies between -254 and +1. Important region(s) lies between -350 bp to -255 bp upstream in the promoter, which might have important elements needed to control CS6 gene expression.

Keywords: microbiology, promoter, colonization factor, ETEC

Procedia PDF Downloads 131
3 Understanding the Prevalence and Expression of Virulence Factors Harbored by Enterotoxigenic Escherichia Coli

Authors: Debjyoti Bhakat, Indranil Mondal, Asish K. Mukhopadayay, Nabendu S. Chatterjee

Abstract:

Enterotoxigenic Escherichia coli is one of the leading causes of diarrhea in infants and travelers in developing countries. Colonization factors play an important role in pathogenesis and are one of the main targets for Enterotoxigenic Escherichia coli (ETEC) vaccine development. However, ETEC vaccines had poorly performed in the past, as the prevalence of colonization factors is region-dependent. There are more than 25 classical colonization factors presently known to be expressed by ETEC, although all are not expressed together. Further, there are other multiple non-classical virulence factors that are also identified. Here the presence and expression of common classical and non-classical virulence factors were studied. Further studies were done on the expression of prevalent colonization factors in different strains. For the prevalence determination, multiplex polymerase chain reaction (PCR) was employed, which was confirmed by simplex PCR. Quantitative RT-PCR was done to study the RNA expression of these virulence factors. Strains negative for colonization factors expression were confirmed by SDS-PAGE. Among the clinical isolates, the most prevalent toxin was est+elt, followed by est and elt, while the pattern was reversed in the control strains. There were 29% and 40% strains negative for any classical colonization factors (CF) or non-classical virulence factors (NCVF) among the clinical and control strains, respectively. Among CF positive ETEC strains, CS6 and CS21 were the prevalent ones in the clinical strains, whereas in control strains, CS6 was the predominant one. For NCVF genes, eatA was the most prevalent among the clinical isolates and etpA for control. CS6 was the most expressed CF, and eatA was the predominantly expressed NCVF for both clinical and controlled ETEC isolates. CS6 expression was more in strains having CS6 alone. Different strains express CS6 at different levels. Not all strains expressed their respective virulence factors. Understanding the prevalent colonization factor, CS6, and its nature of expression will contribute to designing an effective vaccine against ETEC in this region of the globe. The expression pattern of CS6 also will help in examining the relatedness between the ETEC subtypes.

Keywords: classical virulence factors, CS6, diarrhea, enterotoxigenic escherichia coli, expression, non-classical virulence factors

Procedia PDF Downloads 111
2 Molecular Dynamics Simulation of the Effect of the Solid Gas Interface Nanolayer on Enhanced Thermal Conductivity of Copper-CO2 Nanofluid

Authors: Zeeshan Ahmed, Ajinkya Sarode, Pratik Basarkar, Atul Bhargav, Debjyoti Banerjee

Abstract:

The use of CO2 in oil recovery and in CO2 capture and storage is gaining traction in recent years. These applications involve heat transfer between CO2 and the base fluid, and hence, there arises a need to improve the thermal conductivity of CO2 to increase the process efficiency and reduce cost. One way to improve the thermal conductivity is through nanoparticle addition in the base fluid. The nanofluid model in this study consisted of copper (Cu) nanoparticles in varying concentrations with CO2 as a base fluid. No experimental data are available on thermal conductivity of CO2 based nanofluid. Molecular dynamics (MD) simulations are an increasingly adopted tool to perform preliminary assessments of nanoparticle (NP) fluid interactions. In this study, the effect of the formation of a nanolayer (or molecular layering) at the gas-solid interface on thermal conductivity is investigated using equilibrium MD simulations by varying NP diameter and keeping the volume fraction (1.413%) of nanofluid constant to check the diameter effect of NP on the nanolayer and thermal conductivity. A dense semi-solid fluid layer was seen to be formed at the NP-gas interface, and the thickness increases with increase in particle diameter, which also moves with the NP Brownian motion. Density distribution has been done to see the effect of nanolayer, and its thickness around the NP. These findings are extremely beneficial, especially to industries employed in oil recovery as increased thermal conductivity of CO2 will lead to enhanced oil recovery and thermal energy storage.

Keywords: copper-CO2 nanofluid, molecular dynamics simulation, molecular interfacial layer, thermal conductivity

Procedia PDF Downloads 300
1 Using Fractal Architectures for Enhancing the Thermal-Fluid Transport

Authors: Surupa Shaw, Debjyoti Banerjee

Abstract:

Enhancing heat transfer in compact volumes is a challenge when constrained by cost issues, especially those associated with requirements for minimizing pumping power consumption. This is particularly acute for electronic chip cooling applications. Technological advancements in microelectronics have led to development of chip architectures that involve increased power consumption. As a consequence packaging, technologies are saddled with needs for higher rates of power dissipation in smaller form factors. The increasing circuit density, higher heat flux values for dissipation and the significant decrease in the size of the electronic devices are posing thermal management challenges that need to be addressed with a better design of the cooling system. Maximizing surface area for heat exchanging surfaces (e.g., extended surfaces or “fins”) can enable dissipation of higher levels of heat flux. Fractal structures have been shown to maximize surface area in compact volumes. Self-replicating structures at multiple length scales are called “Fractals” (i.e., objects with fractional dimensions; unlike regular geometric objects, such as spheres or cubes whose volumes and surface area values scale as integer values of the length scale dimensions). Fractal structures are expected to provide an appropriate technology solution to meet these challenges for enhanced heat transfer in the microelectronic devices by maximizing surface area available for heat exchanging fluids within compact volumes. In this study, the effect of different fractal micro-channel architectures and flow structures on the enhancement of transport phenomena in heat exchangers is explored by parametric variation of fractal dimension. This study proposes a model that would enable cost-effective solutions for thermal-fluid transport for energy applications. The objective of this study is to ascertain the sensitivity of various parameters (such as heat flux and pressure gradient as well as pumping power) to variation in fractal dimension. The role of the fractal parameters will be instrumental in establishing the most effective design for the optimum cooling of microelectronic devices. This can help establish the requirement of minimal pumping power for enhancement of heat transfer during cooling. Results obtained in this study show that the proposed models for fractal architectures of microchannels significantly enhanced heat transfer due to augmentation of surface area in the branching networks of varying length-scales.

Keywords: fractals, microelectronics, constructal theory, heat transfer enhancement, pumping power enhancement

Procedia PDF Downloads 289