Search results for: Breast Dose
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1956

Search results for: Breast Dose

1776 Breast Cancer Detection Using Machine Learning Algorithms

Authors: Jiwan Kumar, Pooja, Sandeep Negi, Anjum Rouf, Amit Kumar, Naveen Lakra

Abstract:

In modern times where, health issues are increasing day by day, breast cancer is also one of them, which is very crucial and really important to find in the early stages. Doctors can use this model in order to tell their patients whether a cancer is not harmful (benign) or harmful (malignant). We have used the knowledge of machine learning in order to produce the model. we have used algorithms like Logistic Regression, Random forest, support Vector Classifier, Bayesian Network and Radial Basis Function. We tried to use the data of crucial parts and show them the results in pictures in order to make it easier for doctors. By doing this, we're making ML better at finding breast cancer, which can lead to saving more lives and better health care.

Keywords: Bayesian network, radial basis function, ensemble learning, understandable, data making better, random forest, logistic regression, breast cancer

Procedia PDF Downloads 0
1775 Accurate Mass Segmentation Using U-Net Deep Learning Architecture for Improved Cancer Detection

Authors: Ali Hamza

Abstract:

Accurate segmentation of breast ultrasound images is of paramount importance in enhancing the diagnostic capabilities of breast cancer detection. This study presents an approach utilizing the U-Net architecture for segmenting breast ultrasound images aimed at improving the accuracy and reliability of mass identification within the breast tissue. The proposed method encompasses a multi-stage process. Initially, preprocessing techniques are employed to refine image quality and diminish noise interference. Subsequently, the U-Net architecture, a deep learning convolutional neural network (CNN), is employed for pixel-wise segmentation of regions of interest corresponding to potential breast masses. The U-Net's distinctive architecture, characterized by a contracting and expansive pathway, enables accurate boundary delineation and detailed feature extraction. To evaluate the effectiveness of the proposed approach, an extensive dataset of breast ultrasound images is employed, encompassing diverse cases. Quantitative performance metrics such as the Dice coefficient, Jaccard index, sensitivity, specificity, and Hausdorff distance are employed to comprehensively assess the segmentation accuracy. Comparative analyses against traditional segmentation methods showcase the superiority of the U-Net architecture in capturing intricate details and accurately segmenting breast masses. The outcomes of this study emphasize the potential of the U-Net-based segmentation approach in bolstering breast ultrasound image analysis. The method's ability to reliably pinpoint mass boundaries holds promise for aiding radiologists in precise diagnosis and treatment planning. However, further validation and integration within clinical workflows are necessary to ascertain their practical clinical utility and facilitate seamless adoption by healthcare professionals. In conclusion, leveraging the U-Net architecture for breast ultrasound image segmentation showcases a robust framework that can significantly enhance diagnostic accuracy and advance the field of breast cancer detection. This approach represents a pivotal step towards empowering medical professionals with a more potent tool for early and accurate breast cancer diagnosis.

Keywords: mage segmentation, U-Net, deep learning, breast cancer detection, diagnostic accuracy, mass identification, convolutional neural network

Procedia PDF Downloads 45
1774 MITOS-RCNN: Mitotic Figure Detection in Breast Cancer Histopathology Images Using Region Based Convolutional Neural Networks

Authors: Siddhant Rao

Abstract:

Studies estimate that there will be 266,120 new cases of invasive breast cancer and 40,920 breast cancer induced deaths in the year of 2018 alone. Despite the pervasiveness of this affliction, the current process to obtain an accurate breast cancer prognosis is tedious and time consuming. It usually requires a trained pathologist to manually examine histopathological images and identify the features that characterize various cancer severity levels. We propose MITOS-RCNN: a region based convolutional neural network (RCNN) geared for small object detection to accurately grade one of the three factors that characterize tumor belligerence described by the Nottingham Grading System: mitotic count. Other computational approaches to mitotic figure counting and detection do not demonstrate ample recall or precision to be clinically viable. Our models outperformed all previous participants in the ICPR 2012 challenge, the AMIDA 2013 challenge and the MITOS-ATYPIA-14 challenge along with recently published works. Our model achieved an F- measure score of 0.955, a 6.11% improvement in accuracy from the most accurate of the previously proposed models.

Keywords: breast cancer, mitotic count, machine learning, convolutional neural networks

Procedia PDF Downloads 187
1773 Contribution of PALB2 and BLM Mutations to Familial Breast Cancer Risk in BRCA1/2 Negative South African Breast Cancer Patients Detected Using High-Resolution Melting Analysis

Authors: N. C. van der Merwe, J. Oosthuizen, M. F. Makhetha, J. Adams, B. K. Dajee, S-R. Schneider

Abstract:

Women representing high-risk breast cancer families, who tested negative for pathogenic mutations in BRCA1 and BRCA2, are four times more likely to develop breast cancer compared to women in the general population. Sequencing of genes involved in genomic stability and DNA repair led to the identification of novel contributors to familial breast cancer risk. These include BLM and PALB2. Bloom's syndrome is a rare homozygous autosomal recessive chromosomal instability disorder with a high incidence of various types of neoplasia and is associated with breast cancer when in a heterozygous state. PALB2, on the other hand, binds to BRCA2 and together, they partake actively in DNA damage repair. Archived DNA samples of 66 BRCA1/2 negative high-risk breast cancer patients were retrospectively selected based on the presence of an extensive family history of the disease ( > 3 affecteds per family). All coding regions and splice-site boundaries of both genes were screened using High-Resolution Melting Analysis. Samples exhibiting variation were bi-directionally automated Sanger sequenced. The clinical significance of each variant was assessed using various in silico and splice site prediction algorithms. Comprehensive screening identified a total of 11 BLM and 26 PALB2 variants. The variants detected ranged from global to rare and included three novel mutations. Three BLM and two PALB2 likely pathogenic mutations were identified that could account for the disease in these extensive breast cancer families in the absence of BRCA mutations (BLM c.11T > A, p.V4D; BLM c.2603C > T, p.P868L; BLM c.3961G > A, p.V1321I; PALB2 c.421C > T, p.Gln141Ter; PALB2 c.508A > T, p.Arg170Ter). Conclusion: The study confirmed the contribution of pathogenic mutations in BLM and PALB2 to the familial breast cancer burden in South Africa. It explained the presence of the disease in 7.5% of the BRCA1/2 negative families with an extensive family history of breast cancer. Segregation analysis will be performed to confirm the clinical impact of these mutations for each of these families. These results justify the inclusion of both these genes in a comprehensive breast and ovarian next generation sequencing cancer panel and should be screened simultaneously with BRCA1 and BRCA2 as it might explain a significant percentage of familial breast and ovarian cancer in South Africa.

Keywords: Bloom Syndrome, familial breast cancer, PALB2, South Africa

Procedia PDF Downloads 203
1772 Chrysin-Loaded PLGA-PEG Nanoparticles Designed for Enhanced Inhibitory Effect on the Breast Cancer Cell Line

Authors: Faraz Zarghami, Elham Anari, Nosratollah Zarghami, Yones Pilehvar-Soltanahmadi, Abolfazl Akbarzadeh, Sepideh Jalilzadeh-Tabrizi

Abstract:

The development of nanotherapy has presented a new method of drug delivery targeted directly to the neoplasmic tissues, to maximize the action with fewer dose requirements. In the past two decades, poly(lactic-co-glycolic acid) (PLGA) has frequently been investigated by many researchers and is a popular polymeric candidate, due to its biocompatibility and biodegradability, exhibition of a wide range of erosion times, tunable mechanical properties, and most notably, because it is a FDA-approved polymer. Chrysin is a natural flavonoid which has been reported to have some significant biological effects on the processes of chemical defense, nitrogen fixation, inflammation, and oxidation. However, the low solubility in water decreases its bioavailability and consequently disrupts the biomedical benefits. Being loaded with PLGA-PEG increases chrysin solubility and drug tolerance, and decreases the discordant effects of the drug. The well-structured chrysin efficiently accumulates in the breast cancer cell line (T47D). In the present study, the structure and chrysin loading were delineated using proton nuclear magnetic resonance (HNMR), Fourier-transform infrared spectroscopy (FT-IR), and scanning electron microscopy (SEM), and the in vitro cytotoxicity of pure and nanochrysin was studied by the MTT assay. Next, the RNA was exploited and the cytotoxic effects of chrysin were studied by real-time PCR. In conclusion, the nanochrysin therapy developed is a novel method that could increase cytotoxicity to cancer cells without damaging the normal cells, and would be promising in breast cancer therapy.

Keywords: MTT assay, chrysin, flavonoids, nanotherapy

Procedia PDF Downloads 227
1771 Peruvian Diagnostic Reference Levels for Patients Undergoing Different X-Rays Procedures

Authors: Andres Portocarrero Bonifaz, Caterina Sandra Camarena Rodriguez, Ricardo Palma Esparza, Nicolas Antonio Romero Carlos

Abstract:

Reference levels for common X-rays procedures have been set in many protocols. In Peru, during quality control tests, the dose tolerance is set by these international recommendations. Nevertheless, further studies can be made to assess the national reality and relate dose levels with different parameters such as kV, mA/mAs, exposure time, type of processing (digital, digitalized or conventional), etc. In this paper three radiologic procedures were taken into account for study, general X-rays (fixed and mobile), intraoral X-rays (fixed, mobile and portable) and mammography. For this purpose, an Unfors Xi detector was used; the dose was measured at a focus - detector distance which varied depending on the procedure, and was corrected afterward to find the surface entry dose. The data used in this paper was gathered over a period of over 3 years (2015-2018). In addition, each X-ray machine was taken into consideration only once. The results hope to achieve a new standard which reflects the local practice, and address the issues of the ‘Bonn Call for Action’ in Peru. For this purpose, the 75% percentile of the dose of each radiologic procedure was calculated. In future quality control services, those machines with dose values higher than the selected threshold should be informed that they surpass the reference dose levels established in comparison other radiological centers in the country.

Keywords: general X-rays, intraoral X-rays, mammography, reference dose levels

Procedia PDF Downloads 122
1770 Hyper Tuned RBF SVM: Approach for the Prediction of the Breast Cancer

Authors: Surita Maini, Sanjay Dhanka

Abstract:

Machine learning (ML) involves developing algorithms and statistical models that enable computers to learn and make predictions or decisions based on data without being explicitly programmed. Because of its unlimited abilities ML is gaining popularity in medical sectors; Medical Imaging, Electronic Health Records, Genomic Data Analysis, Wearable Devices, Disease Outbreak Prediction, Disease Diagnosis, etc. In the last few decades, many researchers have tried to diagnose Breast Cancer (BC) using ML, because early detection of any disease can save millions of lives. Working in this direction, the authors have proposed a hybrid ML technique RBF SVM, to predict the BC in earlier the stage. The proposed method is implemented on the Breast Cancer UCI ML dataset with 569 instances and 32 attributes. The authors recorded performance metrics of the proposed model i.e., Accuracy 98.24%, Sensitivity 98.67%, Specificity 97.43%, F1 Score 98.67%, Precision 98.67%, and run time 0.044769 seconds. The proposed method is validated by K-Fold cross-validation.

Keywords: breast cancer, support vector classifier, machine learning, hyper parameter tunning

Procedia PDF Downloads 35
1769 PCR Based DNA Analysis in Detecting P53 Mutation in Human Breast Cancer (MDA-468)

Authors: Debbarma Asis, Guha Chandan

Abstract:

Tumor Protein-53 (P53) is one of the tumor suppressor proteins. P53 regulates the cell cycle that conserves stability by preventing genome mutation. It is named so as it runs as 53-kilodalton (kDa) protein on Polyacrylamide gel electrophoresis although the actual mass is 43.7 kDa. Experimental evidence has indicated that P53 cancer mutants loses tumor suppression activity and subsequently gain oncogenic activities to promote tumourigenesis. Tumor-specific DNA has recently been detected in the plasma of breast cancer patients. Detection of tumor-specific genetic materials in cancer patients may provide a unique and valuable tumor marker for diagnosis and prognosis. Commercially available MDA-468 breast cancer cell line was used for the proposed study.

Keywords: tumor protein (P53), cancer mutants, MDA-468, tumor suppressor gene

Procedia PDF Downloads 444
1768 A Comparison of TLD Measurements to MIRD Estimates of the Dose to the Ovaries and Uterus from Tc-99m in Liver

Authors: Karim Adinehvand, Bakhtiar Azadbakht, Amin Sahebnasagh

Abstract:

Relation to high absorption fraction of Tc SESTAMIBI by internal organs in heart scan, and these organs are near to generation organs (Ovaries and uterus). In this study, Liver is specified as source organ. Method: we have set amount of absorbed fraction radiopharmaceutical in position of Liver in RANDO-phantom in form of elliptical surfaces, then absorbed dose to ovaries and uterus measured by TLD-100 that had set at position of these organs in RANDO-phantom. Calculation had done by MIRD method. Results from direct measurement and MIRD method are too similar. The absorbed dose to uterus and ovaries for Rest are 26.05µGyMBq-1, 17.23µGyMBq-1 and for Stress are 2.04µGyMBq-1, 1.35µGyMBq-1 respectively.

Keywords: absorbed dose, TLD, MIRD, RANDO-phantom, Tc-99m

Procedia PDF Downloads 532
1767 Developing a Health Literacy Questionnaire in Breast Cancer

Authors: Lida Moghaddam-Banaem, Mahmood Tavoosi, Soheila Khalili

Abstract:

Objective: The main objective of this study was designing a breast cancer health literacy questionnaire and assess its psychometric properties. Methods: A comprehensive literature review was performed to develop a primary questionnaire consisting of five domains. Qualitative and quantitative content validity were assessed by relevant experts, and after some modifications, the content validity index (CVI) and content validity ratio (CVR) were calculated. Qualitative and quantitative face validity were evaluated by a number of patients, and the impact score for each item was calculated. 225 women with breast cancer were asked to fill out the questionnaire and construct validity was determined by using exploratory factor analysis. The reliability was tested by Cronbach's alpha coefficient. Results: A 36-item questionnaire with five domains of reading, having access, understanding, assessing/judgment, and decision making/behavior was designed. 2 items were omitted in the qualitative content validity process. All items achieved optimum values in CVI, CVR and impact scores. Content and face validity of the questionnaire were confirmed too. According to the exploratory factor analysis, the five-factor solution accounted for 64.98 percent of the observed variance. Conclusion: Due to the obtained satisfactory validity and reliability, this tool can be used to assess health literacy in women with breast cancer. Health policy makers can use these findings for improving health-related behaviors in breast cancer patients.

Keywords: health literacy, breast cancer, questionnaire, psychometric properties

Procedia PDF Downloads 200
1766 Microwave Tomography: The Analytical Treatment for Detecting Malignant Tumor Inside Human Body

Authors: Muhammad Hassan Khalil, Xu Jiadong

Abstract:

Early detection through screening is the best tool short of a perfect treatment against the malignant tumor inside the breast of a woman. By detecting cancer in its early stages, it can be recognized and treated before it has the opportunity to spread and change into potentially dangerous. Microwave tomography is a new imaging method based on contrast in dielectric properties of materials. The mathematical theory of microwave tomography involves solving an inverse problem for Maxwell’s equations. In this paper, we present designed antenna for breast cancer detection, which will use in microwave tomography configuration.

Keywords: microwave imaging, inverse scattering, breast cancer, malignant tumor detection

Procedia PDF Downloads 325
1765 Ultra Wideband Breast Cancer Detection by Using SAR for Indication the Tumor Location

Authors: Wittawat Wasusathien, Samran Santalunai, Thanaset Thosdeekoraphat, Chanchai Thongsopa

Abstract:

This paper presents breast cancer detection by observing the specific absorption rate (SAR) intensity for identification tumor location, the tumor is identified in coordinates (x,y,z) system. We examined the frequency between 4-8 GHz to look for the most appropriate frequency. Results are simulated in frequency 4-8 GHz, the model overview include normal breast with 50 mm radian, 5 mm diameter of tumor, and ultra wideband (UWB) bowtie antenna. The models are created and simulated in CST Microwave Studio. For this simulation, we changed antenna to 5 location around the breast, the tumor can be detected when an antenna is close to the tumor location, which the coordinate of maximum SAR is approximated the tumor location. For reliable, we experiment by random tumor location to 3 position in the same size of tumor and simulation the result again by varying the antenna position in 5 position again, and it also detectable the tumor position from the antenna that nearby tumor position by maximum value of SAR, which it can be detected the tumor with precision in all frequency between 4-8 GHz.

Keywords: specific absorption rate (SAR), ultra wideband (UWB), coordinates, cancer detection

Procedia PDF Downloads 371
1764 Breast Cancer Mortality and Comorbidities in Portugal: A Predictive Model Built with Real World Data

Authors: Cecília M. Antão, Paulo Jorge Nogueira

Abstract:

Breast cancer (BC) is the first cause of cancer mortality among Portuguese women. This retrospective observational study aimed at identifying comorbidities associated with BC female patients admitted to Portuguese public hospitals (2010-2018), investigating the effect of comorbidities on BC mortality rate, and building a predictive model using logistic regression. Results showed that the BC mortality in Portugal decreased in this period and reached 4.37% in 2018. Adjusted odds ratio indicated that secondary malignant neoplasms of liver, of bone and bone marrow, congestive heart failure, and diabetes were associated with an increased chance of dying from breast cancer. Although the Lisbon district (the most populated area) accounted for the largest percentage of BC patients, the logistic regression model showed that, besides patient’s age, being resident in Bragança, Castelo Branco, or Porto districts was directly associated with an increase of the mortality rate.

Keywords: breast cancer, comorbidities, logistic regression, adjusted odds ratio

Procedia PDF Downloads 54
1763 Assessing Relationships between Glandularity and Gray Level by Using Breast Phantoms

Authors: Yun-Xuan Tang, Pei-Yuan Liu, Kun-Mu Lu, Min-Tsung Tseng, Liang-Kuang Chen, Yuh-Feng Tsai, Ching-Wen Lee, Jay Wu

Abstract:

Breast cancer is predominant of malignant tumors in females. The increase in the glandular density increases the risk of breast cancer. BI-RADS is a frequently used density indicator in mammography; however, it significantly overestimates the glandularity. Therefore, it is very important to accurately and quantitatively assess the glandularity by mammography. In this study, 20%, 30% and 50% glandularity phantoms were exposed using a mammography machine at 28, 30 and 31 kVp, and 30, 55, 80 and 105 mAs, respectively. The regions of interest (ROIs) were drawn to assess the gray level. The relationship between the glandularity and gray level under various compression thicknesses, kVp, and mAs was established by the multivariable linear regression. A phantom verification was performed with automatic exposure control (AEC). The regression equation was obtained with an R-square value of 0.928. The average gray levels of the verification phantom were 8708, 8660 and 8434 for 0.952, 0.963 and 0.985 g/cm3, respectively. The percent differences of glandularity to the regression equation were 3.24%, 2.75% and 13.7%. We concluded that the proposed method could be clinically applied in mammography to improve the glandularity estimation and further increase the importance of breast cancer screening.

Keywords: mammography, glandularity, gray value, BI-RADS

Procedia PDF Downloads 459
1762 Determining the Effectiveness of Radiation Shielding and Safe Time for Radiation Worker by Employing Monitoring of Accumulation Dose in the Operator Room of CT Scan

Authors: Risalatul Latifah, Bunawas Bunawas, Lailatul Muqmiroh, Anggraini D. Sensusiati

Abstract:

Along with the increasing frequency of the use of CT-Scan for radiodiagnostics purposes, it is necessary to study radiation protection. This study examined aspects of radiation protection of workers. This study tried using thermoluminescent dosimeter (TLD) for evaluating radiation shielding and estimating safe time for workers during CT Scan examination. Six TLDs were placed on door, wall, and window inside and outside of the CT Scan room for 1 month. By using TLD monitoring, it could be seen how much radiation was exposed in the operator room. The results showed the effective dose at door, window, and wall was respectively 0.04 mSv, 0.05 mSv, and 0.04 mSv. With these values, it could be evaluated the effectiveness of radiation shielding on doors, glass and walls were respectively 90.6%, 95.5%, and 92.2%. By applying the dose constraint and the estimation of the accumulated dose for one month, radiation workers were still safe to perform the irradiation for 180 patients.

Keywords: CT scan room, TLD, radiation worker, dose constraint

Procedia PDF Downloads 252
1761 Monte Carlo Simulation Study on Improving the Flatting Filter-Free Radiotherapy Beam Quality Using Filters from Low- z Material

Authors: H. M. Alfrihidi, H.A. Albarakaty

Abstract:

Flattening filter-free (FFF) photon beam radiotherapy has increased in the last decade, which is enabled by advancements in treatment planning systems and radiation delivery techniques like multi-leave collimators. FFF beams have higher dose rates, which reduces treatment time. On the other hand, FFF beams have a higher surface dose, which is due to the loss of beam hardening effect caused by the presence of the flatting filter (FF). The possibility of improving FFF beam quality using filters from low-z materials such as steel and aluminium (Al) was investigated using Monte Carlo (MC) simulations. The attenuation coefficient of low-z materials for low-energy photons is higher than that of high-energy photons, which leads to the hardening of the FFF beam and, consequently, a reduction in the surface dose. BEAMnrc user code, based on Electron Gamma Shower (EGSnrc) MC code, is used to simulate the beam of a 6 MV True-Beam linac. A phase-space (phosphor) file provided by Varian Medical Systems was used as a radiation source in the simulation. This phosphor file was scored just above the jaws at 27.88 cm from the target. The linac from the jaw downward was constructed, and radiation passing was simulated and scored at 100 cm from the target. To study the effect of low-z filters, steel and Al filters with a thickness of 1 cm were added below the jaws, and the phosphor file was scored at 100 cm from the target. For comparison, the FF beam was simulated using a similar setup. (BEAM Data Processor (BEAMdp) is used to analyse the energy spectrum in the phosphorus files. Then, the dose distribution resulting from these beams was simulated in a homogeneous water phantom using DOSXYZnrc. The dose profile was evaluated according to the surface dose, the lateral dose distribution, and the percentage depth dose (PDD). The energy spectra of the beams show that the FFF beam is softer than the FF beam. The energy peaks for the FFF and FF beams are 0.525 MeV and 1.52 MeV, respectively. The FFF beam's energy peak becomes 1.1 MeV using a steel filter, while the Al filter does not affect the peak position. Steel and Al's filters reduced the surface dose by 5% and 1.7%, respectively. The dose at a depth of 10 cm (D10) rises by around 2% and 0.5% due to using a steel and Al filter, respectively. On the other hand, steel and Al filters reduce the dose rate of the FFF beam by 34% and 14%, respectively. However, their effect on the dose rate is less than that of the tungsten FF, which reduces the dose rate by about 60%. In conclusion, filters from low-z material decrease the surface dose and increase the D10 dose, allowing for a high-dose delivery to deep tumors with a low skin dose. Although using these filters affects the dose rate, this effect is much lower than the effect of the FF.

Keywords: flattening filter free, monte carlo, radiotherapy, surface dose

Procedia PDF Downloads 43
1760 Human Absorbed Dose Estimation of a New In-111 Imaging Agent Based on Rat Data

Authors: H. Yousefnia, S. Zolghadri

Abstract:

The measurement of organ radiation exposure dose is one of the most important steps to be taken initially, for developing a new radiopharmaceutical. In this study, the dosimetric studies of a novel agent for SPECT-imaging of the bone metastasis, 111In-1,4,7,10-tetraazacyclododecane-1,4,7,10 tetraethylene phosphonic acid (111In-DOTMP) complex, have been carried out to estimate the dose in human organs based on the data derived from rats. The radiolabeled complex was prepared with high radiochemical purity in the optimal conditions. Biodistribution studies of the complex was investigated in the male Syrian rats at selected times after injection (2, 4, 24 and 48 h). The human absorbed dose estimation of the complex was made based on data derived from the rats by the radiation absorbed dose assessment resource (RADAR) method. 111In-DOTMP complex was prepared with high radiochemical purity of >99% (ITLC). Total body effective absorbed dose for 111In-DOTMP was 0.061 mSv/MBq. This value is comparable to the other 111In clinically used complexes. The results show that the dose with respect to the critical organs is satisfactory within the acceptable range for diagnostic nuclear medicine procedures. Generally, 111In-DOTMP has interesting characteristics and can be considered as a viable agent for SPECT-imaging of the bone metastasis in the near future.

Keywords: In-111, DOTMP, Internal Dosimetry, RADAR

Procedia PDF Downloads 373
1759 Investigation p53 Codon 72 Polymorphism and miR-146a rs2910164 Polymorphism in Breast Cancer

Authors: Marjan Moradi Fard, Hossein Rassi, Masoud Houshmand

Abstract:

Aim: Breast cancer is one of the most common cancers affecting the morbidity and mortality of Iranian women. This disease is a result of collective alterations of oncogenes and tumor suppressor genes. Studies have produced conflicting results concerning the role of p53 codon 72 polymorphism (G>C) and miR-146a rs2910164 polymorphism (G>C) on the risk of several cancers; therefore, a research was performed to estimate the association between the p53 codon 72 polymorphism and miR-146a rs2910164 polymorphism in breast cancer. Methods and Materials: A total of 45 archival breast cancer samples from khatam hospital and 40 healthy samples were collected. Verification of each cancer reported in a relative was sought through the pathology reports of the hospital records. Then, DNA extracted from all samples by standard methods and p53 codon 72 polymorphism genotypes and miR-146a rs2910164 polymorphism genotypes were analyzed using multiplex PCR. The tubules, mitotic activity, necrosis, polymorphism and grade of breast cancer were staged by Nottingham histological grading and immunohistochemical staining of the sections from the paraffin wax embedded tissues for the expression of ER, PR and p53 was carried out using a standard method. Finally, data analysis was performed using the 7 version of the Epi Info(TM) 2012 software and test chi-square(x2) for trend. Results: Successful DNA extraction was assessed by PCR amplification of b-actin gene (99 bp). According to the results, p53 GG genotype and miR-146a rs2910164 CC genotype was significantly associated with increased risk of breast cancer in the study population. In this study, we established that tumors of p53 GG genotype and miR-146a rs2910164 CC genotype exhibited higher mitotic activity, higher polymorphism, lower necrosis, lower tubules, higher ER- and PR-negatives and lower TP53-positives than the other genotypes. Conclusion: The present study provided preliminary evidence that a p53 GG genotype may effect breast cancer risk in the study population, interacting synergistically with miR-146a rs2910164 CC genotype. Our results demonstrate that the testing of p53 codon 72 polymorphism genotypes and miR-146a rs2910164 polymorphism genotypes in combination with clinical parameters can serve as major risk factors in the early identification of breast cancers.

Keywords: breast cancer, p53 codon 72 polymorphism, miR-146a rs2910164 polymorphism, genotypes

Procedia PDF Downloads 309
1758 The Effectiveness of Laughing Qigong for Women with Breast Cancer in Community

Authors: Chueh Chang, Chia-jung Hsieh, Fu-yu Yu, Yu-Hwa Lin

Abstract:

Background:The majority of women diagnosed with breast cancer undergo treatment involving surgery and radiotherapy or chemotherapy, or both. With these major advances in breast cancer management, many patients still have to deal with short or long-term side effects and psychological distress related to the disease and treatment, which have a substantial impact on their quality of life. The Laughing Qigong Program (LQP) is an interactive laughter program that combines the physical and physiological benefits of laughter with the mental benefits of Chinese qigong. Purpose: In order to improve the quality of life for breast cancer women in the community as well as echoing the WHO 2004 “Promoting Mental Health” for every one. This study focused on how to promote the positive mental health for women of breast cancer through the “laughter program” in Taiwan. During the presentation, how to practice Laughing Qigong will be demonstrated. Method: Using nonequivalent pretest-posttest design, ix-one breast cancer patients were volunteered to enroll in this study from the Taiwan Breast Cancer Alliance (TBCA). Thirty patients were assigned to the experimental group and the other 31 patients were assigned to the control group. The women who were assigned to the experimental group received laughter program one hour per session, once a week, totally 12 sessions. All subjects were tested before and after the intervention on the following: Self-Esteem scale (RSE), Face Scale (FS), Anxiety and pain experience were measured as psychological markers; saliva cortisol (CS) as an immunological marker; blood pressure (BP), heart rate (HR),and heart rate variability (HRV) as physiological markers of the body’s response to stress. Results: After comparing the experimental and control groups, the results revealed that those breast cancer women with “laughing program” their sense of humor were improved, less uncomfortable on self report physical conditions, more positive attitudes toward stress management by using laughter, and had emotional improvement according to the face scale.

Keywords: mental health promotion, breast cancer, laughing Qigong, women

Procedia PDF Downloads 457
1757 Prognostic Value of Tumor Markers in Younger Patients with Breast Cancer

Authors: Lola T. Alimkhodjaeva, Lola T. Zakirova, Soniya S. Ziyavidenova

Abstract:

Background: Breast cancer occupies the first place among the cancer in women in the world. It is urgent today to study the role of molecular markers which are capable of predicting the dynamics and outcome of the disease. The aim of this study is to define the prognostic value of the content of estrogen receptor (ER), progesterone receptor (PgR), and amplification of HER-2 / neu oncoprotein by studying 3 and 5-year overall and relapse-free survival in 470 patients with primary operable and 280 patients with locally–advanced breast cancer. Materials and methods: Study results of 3 and 5-year overall and relapse-free survival, depending on the content of RE, PgR in primary operable patients showed that ER positive (+) and PgR (+) survival was 100 (96.2%) and 97.3 (94.6%), for ER negative (-) and PgR (-) - 69.2 (60.3%) and 65.4 (57.7%), for ER positive (+) and negative PgR (-) 87.4 (80.1%) and 81.5 (79.3%), for ER negative (-) and positive PgR (+) - 97.4 (93.4%) and 90.4 (88.5%), respectively. Survival results depended also on the level of HER-2 / neu expression. In patients with HER-2 / neu negative the survival rates were as follows: 98.6 (94.7%) and 96.2 (92.3%). In group of patients with the level of HER-2 / neu (2+) expression these figures were: 45.3 (44.3%) and 45.1 (40.2%), and in group of patients with the level of HER-2 / neu (3+) expression - 41.2 (33.1%) and 34.3 (29.4%). The combination of ER negative (-), PgR (-), HER-2 / neu (-) they were 27.2 (25.4%) and 19.5 (15.3%), respectively. In patients with locally-advanced breast cancer the results of 3 and 5-year OS and RFS for ER (+) and PgR (+) were 76.3 (69.3%) and 62.2 (61.4%), for ER (-) and RP (-) 29.1 (23.7%) and 18.3 (12.6%), for ER (+) and PgR (-) 61.2 (47.2%) and 39.4 (25.6%), for ER (-) and PgR (+) 54.3 (43.1%) and 41.3 (18.3%), respectively. The level of HER-2 / neu expression also affected the survival results. Therefore, in HER-2/ neu negative patients the survival rate was 74.1 (67.6%) and 65.1 (57.3%), with the level of expression (2+) 20.4 (14.2%) and 8.6 (6.4%), with the level of expression (3+) 6.2 (3.1%) and 1.2 (1.5%), respectively. The combination for ER, PgR, HER-2 / neu negative was 22.1 (14.3%) and 8.4 (1.2%). Conclusion: Thus, the presence of steroid hormone receptors in breast tumor tissues at primary operable and locally- advanced process as the lack of HER-2/neu oncoprotein correlates with the highest rates of 3- and 5-year overall and relapse-free survival. The absence of steroid hormone receptors as well as of HER-2/neu overexpression in malignant breast tissues significantly degrades the 3- and 5-year overall and relapse-free survival. Tumors with ER, PgR and HER-2/neu negative have the most unfavorable prognostics.

Keywords: breast cancer, estrogen receptor, oncoprotein, progesterone receptor

Procedia PDF Downloads 152
1756 Influence of ABCB1 2677G > T Single Nucleotide Polymorphism on Warfarin Maintenance Therapy among Patients with Prosthetic Heart Valve

Authors: M. G. Gopisankar, A. Surendiran, M. Hemachandren

Abstract:

The dose requirement of warfarin to achieve target INR range varies in patients with prosthetic heart valve. This variation in is affected by both genetic and non-genetic factors. Earlier studies have identified role of CYP2C9 and VKORC1 genetic polymorphisms on warfarin dose requirement. Warfarin being a substrate for drug transporter, P-glycoprotein coded by ABCB1 gene, may also be influenced by its genetic polymorphisms. This study was aimed to study the effect of single nucleotide polymorphism (SNP), ABCB1 2677G > T on warfarin maintenance dose requirement in patients with steady-state International Normalized Ratio (INR). The median dose requirement was significantly different between the genotype groups GG vs. GT (35 ± 20; 42.5 ± 18, p < 0.05), GG vs. TT (35 ± 20; 41.25 ± 25, p<0.05). There was no significant difference between GT vs. TT. In conclusion, patients with variant allele require a higher weekly maintenance dose of warfarin compared to patients without variant allele.

Keywords: warfarin pharamcogenetics, pharmacogenomics of warfarin, ABCB1 and warfarin, pglycoprotein and warfarin

Procedia PDF Downloads 222
1755 Concentration of Zinc Micronutrients in Breast Milk Based on Determinant of Mother and Baby in Kassi-Kassi Health Center

Authors: Andi Tenri Ayu Rahman, Citrakesumasari, Devintha Virani

Abstract:

Breast milk is the complex biological fluid mix of macronutrient and micronutrient that are considered as perfect food for babies. Zinc has a role in various biological functions and physical growth. This research aims to know the average zinc (Zn) micronutrients content of breast milk by determinants of infant (birth weight) and mother (nutritional status and food intake) and description of the pattern of mothers breastfeeding. The type of research used is observational analytic with cross-sectional study design. The population was 41 mothers in Kassi-Kassi health center within one month. Sample research is mothers who gave birth at term and breastfed her baby. Sampling was done with random sampling technique involving 37 people. Samples of breast milk were analyzed in the laboratory by using the method of Atomic Absorption Spectrofotometry (AAS). This research find that from the samples (n=37) the average contents of zinc in the breast milk is 0,88±0,54 mg/L with the highest value on the group of low birth weight babies (1,13 ± 0,67mg/L), mothers who had normal nutritional status (0,981 ± 0,514 mg/L) and intake low zinc (0,94 ± 0,54 mg/L). Regarding breastfeeding pattern, 67,6% of the samples had had breastfeeding experience and 81,1% of breastfed more than eight times a day. In summary, the highest average value of the zinc content of breast milk was in the group of low birth weight babies, mother with normal nutritional status, and mothers having relatively low intake pattern.

Keywords: zinc, breastmilk, mother, baby

Procedia PDF Downloads 155
1754 Reliability of Social Support Measurement Modification of the BC-SSAS among Women with Breast Cancer Who Undergone Chemotherapy in Selected Hospital, Central Java, Indonesia

Authors: R. R. Dewi Rahmawaty Aktyani Putri, Earmporn Thongkrajai, Dedy Purwito

Abstract:

There were many instruments have been developed to assess social support which has the different dimension in breast cancer patients. The Issue of measurement is a challenge to determining the component of dimensional concept, defining the unit of measurement, and establishing the validity and reliability of the measurement. However, the instruments where need to know how much support which obtained and perceived among women with breast cancer who undergone chemotherapy which it can help nurses to prevent of non-adherence in chemotherapy. This study aimed to measure the reliability of BC-SSAS instrument among 30 Indonesian women with breast cancer aged 18 years and above who undergone chemotherapy for six cycles in the oncological unit of Outpatient Department (OPD), Margono Soekardjo Hospital, Central Java, Indonesia. Data were collected during October to December 2015 by using modified the Breast Cancer Social Support Assessment (BC-SSAS). The Cronbach’s alpha analysis was carried out to measure internal consistency for reliability test of BC-SSAS instrument. This study used five experts for content validity index. The results showed that for content validity, I-CVI was 0.98 and S-CVI was 0.98; Cronbach’s alpha value was 0.971 and the Cronbach’s alpha coefficients for the subscales were high, with 0.903 for emotional support, 0.865 for informational support, 0.901 for tangible support, 0.897 for appraisal support and 0.884 for positive interaction support. The results confirmed that the BC-SSAS instrument has high reliability. BC-SSAS instruments were reliable and can be used in health care services to measure the social support received and perceived among women with breast cancer who undergone chemotherapy so that preventive interventions can be developed and the quality of health services can be improved.

Keywords: BC-SSAS, women with breast cancer, chemotherapy, Indonesia

Procedia PDF Downloads 338
1753 Prognostic Significance of Nuclear factor kappa B (p65) among Breast Cancer Patients in Cape Coast Teaching Hospital

Authors: Precious Barnes, Abraham Mensah, Leonard Derkyi-Kwarteng, Benjamin Amoani, George Adjei, Ernest Adankwah, Faustina Pappoe, Kwabena Dankwah, Daniel Amoako-Sakyi, Samuel Victor Nuvor, Dorcas Obiri-Yeboah, Ewura Seidu Yahaya, Patrick Kafui Akakpo, Roland Osei Saahene

Abstract:

Context: Breast cancer is a prevalent and aggressive type of cancer among African women, with high mortality rates in Ghana. Nuclear factor kappa B (NF-kB) is a transcription factor that has been associated with tumor progression in breast cancer. However, there is a lack of published data on NF-kB in breast cancer patients in Ghana or other African countries. Research Aim: The aim of this study was to assess the prognostic significance of NF-kB (p65) expression and its association with various clinicopathological features in breast cancer patients at the Cape Coast Teaching Hospital in Ghana. Methodology: A total of 90 formalin-fixed breast cancer tissues and 15 normal breast tissues were used in this study. The expression level of NF-kB (p65) was examined using immunohistochemical techniques. Correlation analysis between NF-kB (p65) expression and clinicopathological features was performed using SPSS version 25. Findings: The study found that NF-kB (p65) was expressed in 86.7% of breast cancer tissues. There was a significant relationship between NF-kB (p65) expression and tumor grade, proliferation index (Ki67), and molecular subtype. High-level expression of NF-kB (p65) was more common in tumor grade 3 compared to grade 1, and Ki67 > 20 had higher expression of NF-kB (p65) compared to Ki67 ≤ 20. Triple-negative breast cancer patients had the highest overexpression of NF-kB (p65) compared to other molecular subtypes. There was no significant association between NF-kB (p65) expression and other clinicopathological parameters. Theoretical Importance: This study provides important insights into the expression of NF-kB (p65) in breast cancer patients in Ghana, particularly in relation to tumor grade and proliferation index. The findings suggest that NF-kB (p65) could serve as a potential biological marker for cancer stage, progression, prognosis and as a therapeutic target. Data Collection and Analysis Procedures: Formalin-fixed breast cancer tissues and normal breast tissues were collected and analyzed using immunohistochemical techniques. Correlation analysis between NF-kB (p65) expression and clinicopathological features was performed using SPSS version 25. Question Addressed: This study addressed the question of the prognostic significance of NF-kB (p65) expression and its association with clinicopathological features in breast cancer patients in Ghana. Conclusion: This study, the first of its kind in Ghana, demonstrates that NF-kB (p65) is highly expressed among breast cancer patients at the Cape Coast Teaching Hospital, especially in triple-negative breast cancer patients. The expression of NF-kB (p65) is associated with tumor grade and proliferation index. NF-kB (p65) could potentially serve as a biological marker for cancer stage, progression, prognosis, and as a therapeutic target.

Keywords: breast cancer, Ki67, NF-kB (p65), tumor grade

Procedia PDF Downloads 31
1752 Mathematical modeling of the calculation of the absorbed dose in uranium production workers with the genetic effects.

Authors: P. Kazymbet, G. Abildinova, K.Makhambetov, M. Bakhtin, D. Rybalkina, K. Zhumadilov

Abstract:

Conducted cytogenetic research in workers Stepnogorsk Mining-Chemical Combine (Akmola region) with the study of 26341 chromosomal metaphase. Using a regression analysis with program DataFit, version 5.0, dependence between exposure dose and the following cytogenetic exponents has been studied: frequency of aberrant cells, frequency of chromosomal aberrations, frequency of the amounts of dicentric chromosomes, and centric rings. Experimental data on calibration curves "dose-effect" enabled the development of a mathematical model, allowing on data of the frequency of aberrant cells, chromosome aberrations, the amounts of dicentric chromosomes and centric rings calculate the absorbed dose at the time of the study. In the dose range of 0.1 Gy to 5.0 Gy dependence cytogenetic parameters on the dose had the following equation: Y = 0,0067е^0,3307х (R2 = 0,8206) – for frequency of chromosomal aberrations; Y = 0,0057е^0,3161х (R2 = 0,8832) –for frequency of cells with chromosomal aberrations; Y =5 Е-0,5е^0,6383 (R2 = 0,6321) – or frequency of the amounts of dicentric chromosomes and centric rings on cells. On the basis of cytogenetic parameters and regression equations calculated absorbed dose in workers of uranium production at the time of the study did not exceed 0.3 Gy.

Keywords: Stepnogorsk, mathematical modeling, cytogenetic, dicentric chromosomes

Procedia PDF Downloads 441
1751 Preparing a Library of Abnormal Masses for Designing a Long-Lasting Anatomical Breast Phantom for Ultrasonography Training

Authors: Nasibullina A., Leonov D.

Abstract:

The ultrasonography method is actively used for the early diagnosis of various le-sions in the human body, including the mammary gland. The incidence of breast cancer has increased by more than 20%, and mortality by 14% since 2008. The correctness of the diagnosis often directly depends on the qualifications and expe-rience of a diagnostic medical sonographer. That is why special attention should be paid to the practical training of future specialists. Anatomical phantoms are ex-cellent teaching tools because they accurately imitate the characteristics of real hu-man tissues and organs. The purpose of this work is to create a breast phantom for practicing ultrasound diagnostic skills in grayscale and elastography imaging, as well as ultrasound-guided biopsy sampling. We used silicone-like compounds ranging from 3 to 17 on the Shore scale hardness units to simulate soft tissue and lesions. Impurities with experimentally selected concentrations were added to give the phantom the necessary attenuation and reflection parameters. We used 3D modeling programs and 3D printing with PLA plastic to create the casting mold. We developed a breast phantom with inclusions of varying shape, elasticity and echogenicity. After testing the created phantom in B-mode and elastography mode, we performed a survey asking 19 participants how realistic the sonograms of the phantom were. The results showed that the closest to real was the model of the cyst with 9.5 on the 0-10 similarity scale. Thus, the developed breast phantom can be used for ultrasonography, elastography, and ultrasound-guided biopsy training.

Keywords: breast ultrasound, mammary gland, mammography, training phantom, tissue-mimicking materials

Procedia PDF Downloads 48
1750 Biosynthesis of Selenium Oxide Nanoparticles by Streptomyces bikiniensis and Its Cytotoxicity as Antitumor Agents against Hepatocellular and Breast Cells Carcinoma

Authors: Maged Syed Ahamd, Manal Mohamed Yasser, Essam Sholkamy

Abstract:

In this paper, we reported that selenium (Se) nanoparticles were firstly biosynthesized with a simple and eco-friendly biological method. Their shape, size, FTIR (Fourier Transform Infrared spectroscopy), UV–vis spectra, TEM (Transmission Electron Microscopy) images and EDS (Energy Dispersive Spectroscopy) pattern have been analyzed. TEM analyses of the samples obtained at different stages indicated that the formation of these Se nanostructures was governed by an incubation time (12- 24- 48 hours). The Se nanoparticles were initially generated and then would transform into crystal seeds for the subsequent growth of nanowires; however obtaining stable Se nanowire with a diameter of about 15-100 nm. EDS shows that Se nanoparticles are entirely pure. The IR spectra showed the peaks at 550 cm-1, 1635 cm-1, 1994 cm-1 and 3430 cm-1 correspond to the presence of Se-O bending and stretching vibrations. The concentrations of Se-NPs (0, 1, 2, 5 µg/ml) did not give significantly effect on both two cell lines while the highest concentrations (10- 100 µg/ml gave significantly effects on them. The lethal dose (ID50%) of Se-NPs on Hep2 G and MCF-7 cells was obtained at 75.96 and 61.86 µg/ml, respectively. Results showed that Se nanoparticles as anticancer agent against MCF-7 cells were more effective than Hep2 G cells. Our results suggest that Se-NPs may be a candidate for further evaluation as a chemotherapeutic agent for breast and liver cancers.

Keywords: selenium nanoparticle, Streptomyces bikiniensis, nanowires, chemotherapeutic agent

Procedia PDF Downloads 410
1749 Histological Evaluation of the Neuroprotective Roles of Trans Cinnamaldehyde against High Fat Diet and Streptozotozin Induced Neurodegeneration in Wistar Rats

Authors: Samson Ehindero, Oluwole Akinola

Abstract:

Substantial evidence has shown an association between type 2 diabetes (T2D) and cognitive decline, Trans Cinnamaldehyde (TCA) has been shown to have many potent pharmacological properties. In this present study, we are currently investigating the effects of TCA on type II diabetes-induced neurodegeneration. Neurodegeneration was induced in forty (40) adult wistar rats using high fat diet (HFD) for 4 months followed by low dose of streptozotocin (STZ) (40 mg/kg, i.p.) administration. TCA was administered orally for 30 days at the doses of 40mg/kg and 60mg/kg body weight. Animals were randomized and divided into following groups; A- control group, B- diabetic group, C- TCA (high dose), D- diabetic + TCA (high dose), E- diabetic + TCA (high dose) with high fat diet, F- TCA Low dose, G- diabetic + TCA (low dose) and H- diabetic + TCA (low dose) with high fat diet. Animals were subjected to behavioral tests followed by histological studies of the hippocampus. Demented rats showed impaired behavior in Y- Maze test compared to treated and control groups. Trans Cinnamaldehyde restores the histo architecture of the hippocampus of demented rats. This present study demonstrates that treatment with trans- cinnamaldehyde improves behavioral deficits, restores cellular histo architecture in rat models of neurodegeneration.

Keywords: neurodegeneration, trans cinnamaldehyde, high fat diet, streptozotocin

Procedia PDF Downloads 150
1748 An Audit of Local Guidance Compliance For Stereotactic Core Biopsy For DCIS In The Breast Screening Programme

Authors: Aisling Eves, Andrew Pieri, Ross McLean, Nerys Forester

Abstract:

Background: The breast unit local guideline recommends that 12 cores should be used in a stereotactic-guided biopsy to diagnose DCIS. Twelve cores are regarded to provide good diagnostic value without removing more breast tissue than necessary. This study aimed to determine compliance with guidelines and investigated how the number of cores impacted upon the re-excision rate and size discrepancies. Methods: This single-centre retrospective cohort study of 72 consecutive breast screened patients with <15mm DCIS on radiological report underwent stereotactic-guided core biopsy and subsequent surgical excision. Clinical, radiological, and histological data were collected over 5 years, and ASCO guidelines for margin involvement of <2mm was used to guide the need for re-excision. Results: Forty-six (63.9%) patients had <12 cores taken, and 26 (36.1%) patients had ≥12 cores taken. Only six (8.3%) patients had 12 cores taken in their stereotactic biopsy. Incomplete surgical excision was seen in 17 patients overall (23.6%), and of these patients, twelve (70.6%) had fewer than 12 cores taken (p=0.55 for the difference between groups). Mammogram and biopsy underestimated the size of the DCIS in this subgroup by a median of 15mm (range: 6-135mm). Re-excision was required in 9 patients (12.5%), and five patients (6.9%) were found to have invasive ductal carcinoma on excision (80% had <12 cores, p=0.43). Discussion: There is poor compliance with the breast unit local guidelines and higher rates of re-excision in patients who did not have ≥12 cores taken. Taking ≥12 cores resulted in fewer missed invasive cancers lower incomplete excision and re-excision rates.

Keywords: stereotactic core biopsy, DCIS, breast screening, Re-excision rates, core biopsy

Procedia PDF Downloads 92
1747 Absorbed Dose Estimation of 68Ga-EDTMP in Human Organs

Authors: S. Zolghadri, H. Yousefnia, A. R. Jalilian

Abstract:

Bone metastases are observed in a wide range of cancers leading to intolerable pain. While early detection can help the physicians in the decision of the type of treatment, various radiopharmaceuticals using phosphonates like 68Ga-EDTMP have been developed. In this work, due to the importance of absorbed dose, human absorbed dose of this new agent was calculated for the first time based on biodistribution data in Wild-type rats. 68Ga was obtained from 68Ge/68Ga generator with radionuclidic purity and radiochemical purity of higher than 99%. The radiolabeled complex was prepared in the optimized conditions. Radiochemical purity of the radiolabeled complex was checked by instant thin layer chromatography (ITLC) method using Whatman No. 2 paper and saline. The results indicated the radiochemical purity of higher than 99%. The radiolabelled complex was injected into the Wild-type rats and its biodistribution was studied up to 120 min. As expected, major accumulation was observed in the bone. Absorbed dose of each human organ was calculated based on biodistribution in the rats using RADAR method. Bone surface and bone marrow with 0.112 and 0.053 mSv/MBq, respectively, received the highest absorbed dose. According to these results, the radiolabeled complex is a suitable and safe option for PET bone imaging.

Keywords: absorbed dose, EDTMP, ⁶⁸Ga, rats

Procedia PDF Downloads 171