Search results for: Benyamine Abbou
5 When the Lights Go Down in the Delivery Room: Lessons From a Ransomware Attack
Authors: Rinat Gabbay-Benziv, Merav Ben-Natan, Ariel Roguin, Benyamine Abbou, Anna Ofir, Adi Klein, Dikla Dahan-Shriki, Mordechai Hallak, Boris Kessel, Mickey Dudkiewicz
Abstract:
Introduction: Over recent decades, technology has become integral to healthcare, with electronic health records and advanced medical equipment now standard. However, this reliance has made healthcare systems increasingly vulnerable to ransomware attacks. On October 13, 2021, Hillel Yaffe Medical Center experienced a severe ransomware attack that disrupted all IT systems, including electronic health records, laboratory services, and staff communications. The attack, carried out by the group DeepBlueMagic, utilized advanced encryption to lock the hospital's systems and demanded a ransom. This incident caused significant operational and patient care challenges, particularly impacting the obstetrics department. Objective: The objective is to describe the challenges facing the obstetric division following a cyberattack and discuss ways of preparing for and overcoming another one. Methods: A retrospective descriptive study was conducted in a mid-sized medical center. Division activities, including the number of deliveries, cesarean sections, emergency room visits, admissions, maternal-fetal medicine department occupancy, and ambulatory encounters, from 2 weeks before the attack to 8 weeks following it (a total of 11 weeks), were compared with the retrospective period in 2019 (pre-COVID-19). In addition, we present the challenges and adaptation measures taken at the division and hospital levels leading up to the resumption of full division activity. Results: On the day of the cyberattack, critical decisions were made. The media announced the event, calling on patients not to come to our hospital. Also, all elective activities other than cesarean deliveries were stopped. The number of deliveries, admissions, and both emergency room and ambulatory clinic visits decreased by 5%–10% overall for 11 weeks, reflecting the decrease in division activity. Nevertheless, in all stations, there were sufficient activities and adaptation measures to ensure patient safety, decision-making, and workflow of patients were accounted for. Conclusions: The risk of ransomware cyberattacks is growing. Healthcare systems at all levels should recognize this threat and have protocols for dealing with them once they occur.Keywords: ransomware attack, healthcare cybersecurity, obstetrics challenges, IT system disruption
Procedia PDF Downloads 244 Speed Power Control of Double Field Induction Generator
Authors: Ali Mausmi, Ahmed Abbou, Rachid El Akhrif
Abstract:
This research paper aims to reduce the chattering phenomenon due to control by sliding mode control applied on a wind energy conversion system based on the doubly fed induction generator (DFIG). Our goal is to offset the effect of parametric uncertainties and come as close as possible to the dynamic response solicited by the control law in the ideal case and therefore force the active and reactive power generated by the DFIG to accurately follow the reference values which are provided to it. The simulation results using Matlab / Simulink demonstrate the efficiency and performance of the proposed technique while maintaining the simplicity of control by first order sliding mode.Keywords: control of speed, correction of the equivalent command, induction generator, sliding mode
Procedia PDF Downloads 3763 Sliding Mode Control of the Power of Doubly Fed Induction Generator for Variable Speed Wind Energy Conversion System
Authors: Ahmed Abbou, Ali Mousmi, Rachid El Akhrif
Abstract:
This research paper aims to reduce the chattering phenomenon due to control by sliding mode control applied on a wind energy conversion system based on the doubly fed induction generator (DFIG). Our goal is to offset the effect of parametric uncertainties and come as close as possible to the dynamic response solicited by the control law in the ideal case and therefore force the active and reactive power generated by the DFIG to accurately follow the reference values which are provided to it. The simulation results using Matlab / Simulink demonstrate the efficiency and performance of the proposed technique while maintaining the simplicity of control by first order sliding mode.Keywords: correction of the equivalent command, DFIG, induction machine, sliding mode controller
Procedia PDF Downloads 4152 Sensorless Controller of Induction Motor Using Backstepping Approach and Fuzzy MRAS
Authors: Ahmed Abbou
Abstract:
This paper present a sensorless controller designed by the backstepping approach for the speed control of induction motor. In this strategy of control, we also combined the method Fuzzy MRAS to estimate the rotor speed and the observer type Luenburger to observe Rotor flux. The control model involves a division by the flux variable that may lead to unbounded solutions. Such a risk is avoided by basing the controller design on Lyapunov function that accounts for the model singularity. On the other hand, this mixed method gives better results in Sensorless operation and especially at low speed. The response time at 5% of the flux is 20ms while the error between the speed with sensor and the estimated speed remains in the range of ±0.8 rad/s for the rated functioning and ±1.5 rad/s for low speed.Keywords: backstepping approach, fuzzy logic, induction motor, luenburger observer, sensorless MRAS
Procedia PDF Downloads 3731 Optimal Maintenance Policy for a Three-Unit System
Authors: A. Abbou, V. Makis, N. Salari
Abstract:
We study the condition-based maintenance (CBM) problem of a system subject to stochastic deterioration. The system is composed of three units (or modules): (i) Module 1 deterioration follows a Markov process with two operational states and one failure state. The operational states are partially observable through periodic condition monitoring. (ii) Module 2 deterioration follows a Gamma process with a known failure threshold. The deterioration level of this module is fully observable through periodic inspections. (iii) Only the operating age information is available of Module 3. The lifetime of this module has a general distribution. A CBM policy prescribes when to initiate a maintenance intervention and which modules to repair during intervention. Our objective is to determine the optimal CBM policy minimizing the long-run expected average cost of operating the system. This is achieved by formulating a Markov decision process (MDP) and developing the value iteration algorithm for solving the MDP. We provide numerical examples illustrating the cost-effectiveness of the optimal CBM policy through a comparison with heuristic policies commonly found in the literature.Keywords: reliability, maintenance optimization, Markov decision process, heuristics
Procedia PDF Downloads 218