Search results for: vacuum assisted high pressure die casting
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 23138

Search results for: vacuum assisted high pressure die casting

22898 The Impact of Temperature on the Threshold Capillary Pressure of Fine-Grained Shales

Authors: Talal Al-Bazali, S. Mohammad

Abstract:

The threshold capillary pressure of shale caprocks is an important parameter in CO₂ storage modeling. A correct estimation of the threshold capillary pressure is not only essential for CO₂ storage modeling but also important to assess the overall economical and environmental impact of the design process. A standard step by step approach has to be used to measure the threshold capillary pressure of shale and non-wetting fluids at different temperatures. The objective of this work is to assess the impact of high temperature on the threshold capillary pressure of four different shales as they interacted with four different oil based muds, air, CO₂, N₂, and methane. This study shows that the threshold capillary pressure of shale and non-wetting fluid is highly impacted by temperature. An empirical correlation for the dependence of threshold capillary pressure on temperature when different shales interacted with oil based muds and gasses has been developed. This correlation shows that the threshold capillary pressure decreases exponentially as the temperature increases. In this correlation, an experimental constant (α) appears, and this constant may depend on the properties of shale and non-wetting fluid. The value for α factor was found to be higher for gasses than for oil based muds. This is consistent with our intuition since the interfacial tension for gasses is higher than those for oil based muds. The author believes that measured threshold capillary pressure at ambient temperature is misleading and could yield higher values than those encountered at in situ conditions. Therefore one must correct for the impact of temperature when measuring threshold capillary pressure of shale at ambient temperature.

Keywords: capillary pressure, shale, temperature, thresshold

Procedia PDF Downloads 365
22897 Importance of Solubility and Bubble Pressure Models to Predict Pressure of Nitrified Oil Based Drilling Fluid in Dual Gradient Drilling

Authors: Sajjad Negahban, Ruihe Wang, Baojiang Sun

Abstract:

Gas-lift dual gradient drilling is a solution for deepwater drilling challenges. As well, Continuous development of drilling technology leads to increase employment of mineral oil based drilling fluids and synthetic-based drilling fluids, which have adequate characteristics such as: high rate of penetration, lubricity, shale inhibition and low toxicity. The paper discusses utilization of nitrified mineral oil base drilling for deepwater drilling and for more accurate prediction of pressure in DGD at marine riser, solubility and bubble pressure were considered in steady state hydraulic model. The Standing bubble pressure and solubility correlations, and two models which were acquired from experimental determination were applied in hydraulic model. The effect of the black oil correlations, and new solubility and bubble pressure models was evaluated on the PVT parameters such as oil formation volume factor, density, viscosity, volumetric flow rate. Eventually, the consequent simulated pressure profile due to these models was presented.

Keywords: solubility, bubble pressure, gas-lift dual gradient drilling, steady state hydraulic model

Procedia PDF Downloads 270
22896 Effect of Educational Information with Video Compact Disc on Anxiety Level in Patients Undergoing Bronchoscopy in Ramathibodi Hospital

Authors: Chariya Laohavich, Viboon Bunsrangsuk

Abstract:

Objective: Bronchoscopy is a common outpatient procedure. The authors compared the patient anxiety level before and after received video-assisted procedural information. Method: One hundred and twenty patients who never received bronchoscopy and scheduled for elective bronchoscopy at outpatient Bronchosope unit at Ramathibodi Hospital, Mahidol University were randomized into control and intervention group. Video-assisted procedural information was given in intervention group. Pre and post procedural anxiety score were recorded and compared between two groups. Paired T-test was used for statistical analysis. Result: There was statistically significant decrease (p < 0.001) for anxiety score in patients who received video assisted procedural information compare with control group. Conclusion: Video-assisted procedural information should be given to patient who will have bronchoscopy to reduce anxiety.

Keywords: anxiety, bronchoscopy, video compact disc (VCD)

Procedia PDF Downloads 346
22895 Combination of Plantar Pressure and Star Excursion Balance Test for Evaluation of Dynamic Posture Control on High-Heeled Shoes

Authors: Yan Zhang, Jan Awrejcewicz, Lin Fu

Abstract:

High-heeled shoes force the foot into plantar flexion position resulting in foot arch rising and disturbance of the articular congruence between the talus and tibiofibular mortice, all of which may increase the challenge of balance maintenance. Plantar pressure distribution of the stance limb during the star excursion balance test (SEBT) contributes to the understanding of potential sources of reaching excursions in SEBT. The purpose of this study is to evaluate the dynamic posture control while wearing high-heeled shoes using SEBT in a combination of plantar pressure measurement. Twenty healthy young females were recruited. Shoes of three heel heights were used: flat (0.8 cm), low (4.0 cm), high (6.6 cm). The testing grid of SEBT consists of three lines extending out at 120° from each other, which were defined as anterior, posteromedial, and posterolateral directions. Participants were instructed to stand on their dominant limb with the heel in the middle of the testing grid and hands on hips and to reach the non-stance limb as far as possible towards each direction. The distal portion of the reaching limb lightly touched the ground without shifting weight. Then returned the reaching limb to the beginning position. The excursion distances were normalized to leg length. The insole plantar measurement system was used to record peak pressure, contact area, and pressure-time integral of the stance limb. Results showed that normalized excursion distance decreased significantly as heel height increased. The changes of plantar pressure in SEBT as heel height increased were more obvious in the medial forefoot (MF), medial midfoot (MM), rearfoot areas. At MF, the peak pressure and pressure-time integral of low and high shoes increased significantly compared with that of flat shoes, while the contact area decreased significantly as heel height increased. At MM, peak pressure, contact area, and pressure-time integral of high and low shoes were significantly lower than that of flat shoes. To reduce posture instability, the stance limb plantar loading shifted to medial forefoot. Knowledge of this study identified dynamic posture control deficits while wearing high-heeled shoes and the critical role of the medial forefoot in dynamic balance maintenance.

Keywords: dynamic posture control, high-heeled shoes, plantar pressure, star excursion balance test.

Procedia PDF Downloads 133
22894 Disentangling Palliative Care and Euthanasia/Assisted Suicide in Dementia Care

Authors: Michael Joseph Passmore

Abstract:

Euthanasia, or assisted suicide (EAS), refers to the provision of medical assistance to individuals seeking to end their own lives. In Canada, the issue of EAS has been the subject of debate and legislative action for many years. In 2016, the Canadian government passed the Medical Assistance in Dying (MAID) Act. This legalized EAS in Canada is subject to certain eligibility criteria. In 2023, debate in Canada continues regarding the scope of MAID practice and associated legislation. Dementia is an illness that causes suffering at the end of life. Persons suffering due to dementia deserve timely and effective palliative care.

Keywords: palliative care, neurocognitive disorder, dementia, Alzheimer’s disease, euthanasia, assisted suicide, medical ethics, bioethics

Procedia PDF Downloads 86
22893 Analysis of the Development of Communicative Skills After Participating in the Equine-Assisted-Therapy Program Step-By-Step in Communication

Authors: Leticia Souza Guirra, Márcia Eduarda Vieira Ramos, Edlaine Souza Pereira, Leticia Correa Celeste

Abstract:

Introduction: Studies indicate that equine-assisted therapy enables improvements in several areas of functioning that are impaired in children with autism spectrum disorder (ASD), such as social interaction and communication. Objective: The study proposes to analyze the development of dialogic skills of a verbal child with ASD after participating in the equine-assisted therapy Step By Step in Communication. Method: This is quantitative and qualitative research through a case study. It refers to a 6 years old child diagnosed with ASD belonging to a group of practitioners of the Brazilian National Equine-Assited-Therapy Association. The Behavioral Observation Protocol (PROC) was used to evaluate communicative skills before and after the intervention, which consisted of 24 sessions once a week. Results: All conversational skills increased their frequency, with participation in dialogue and initiation of interaction. The child also increases the habit of waiting for his turn and answering the interlocutor. The emission of topics not related to conversation and echolalia showed a significant decrease after the intervention. Conclusion: The studied child showed improvement in communicative skills after participating in the equine-assisted therapy Step By Step in Communication. Contributions: This study contributes to a greater understanding of the impact of equine-assisted therapy on the communicative abilities of children with ASD.

Keywords: equine-assisted-therapy, autism spectrum disorder, language, communication, language and hearing sciences

Procedia PDF Downloads 78
22892 Analysis of Bank Characteristics in a Hydrogen Refueling Station

Authors: Bo Hyun Kim, Sarng Woo Karng

Abstract:

In constructing a hydrogen refueling station, minimizing the volume and reducing the number of banks enable lessening the construction cost. This study aims at performing the dynamic simulation on 250 kg/day of a refueling station for light-duty vehicles. The primary compressor boosts hydrogen from a tube trailer of 250 to 480 bar and stores it in a medium-pressure bank. Then, additional compression of hydrogen from 480 to 900 bar is carried out and stored in a high-pressure bank. Economic analysis was conducted considering the amount of electricity consumed by compression corresponding to the volume and the number of banks (cascade system) in charging mode. NIST REFPROP was selected as the equation of state on the ASPEN HYSYS for thermodynamic analysis of the tube-trailer, the compressors, the chillers, and the banks. Compared to a single high-pressure bank system of 3000 L, the volume of the cascade high-pressure banks (bank1: 250 L and bank 2: 1850 L) was reduced by 30%, and the power consumption of the chiller for precooling was also decreased by 16%.

Keywords: light-duty vehicles, economic analysis, cascade system, hydrogen refueling station

Procedia PDF Downloads 85
22891 Experimental Study of Heat Transfer and Pressure Drop in Serpentine Channel Water Cooler Heat Sink

Authors: Hao Xiaohong, Wu Zongxiang, Chen Xuefeng

Abstract:

With the high power density and high integration of electronic devices, their heat flux has been increasing rapidly. Therefore, an effective cooling technology is essential for the reliability and efficient operation of electronic devices. Liquid cooling is studied increasingly widely for its higher heat transfer efficiency. Serpentine channels are superior in the augmentation of single-phase convective heat transfer because of their better channel velocity distribution. In this paper, eight different frame sizes water-cooled serpentine channel heat sinks are designed to study the heat transfer and pressure drop characteristics. With water as the working fluid, experiment setup is established and the results showed the effect of different channel width, fin thickness and number of channels on thermal resistance and pressure drop.

Keywords: heat transfer, experiment, serpentine heat sink, pressure drop

Procedia PDF Downloads 448
22890 CPT Pore Water Pressure Correlations with PDA to Identify Pile Drivability Problem

Authors: Fauzi Jarushi, Paul Cosentino, Edward Kalajian, Hadeel Dekhn

Abstract:

At certain depths during large diameter displacement pile driving, rebound well over 0.25 inches was experienced, followed by a small permanent set during each hammer blow. High pile rebound (HPR) soils may stop the pile driving and results in a limited pile capacity. In some cases, rebound leads to pile damage, delaying the construction project, and the requiring foundations redesign. HPR was evaluated at seven Florida sites, during driving of square precast, prestressed concrete piles driven into saturated, fine silty to clayey sands and sandy clays. Pile Driving Analyzer (PDA) deflection versus time data recorded during installation, was used to develop correlations between cone penetrometer (CPT) pore-water pressures, pile displacements and rebound. At five sites where piles experienced excessive HPR with minimal set, the pore pressure yielded very high positive values of greater than 20 tsf. However, at the site where the pile rebounded, followed by an acceptable permanent set, the measured pore pressure ranged between 5 and 20 tsf. The pore pressure exhibited values of less than 5 tsf at the site where no rebound was noticed. In summary, direct correlations between CPTu pore pressure and rebound were produced, allowing identification of soils that produce HPR.

Keywords: CPTU, pore water pressure, pile rebound

Procedia PDF Downloads 313
22889 Enhancing the Piezoelectric, Thermal, and Structural Properties of the PVDF-HFP/PZT/GO Composite for Improved Mechanical Energy Harvesting

Authors: Salesabil Labihi, Adil Eddiai, Mounir El Achaby, Mounir Meddad, Omar Cherkaoui, M’hammed Mazroui

Abstract:

Piezoelectric materials provide a promising renewable energy source by converting mechanical energy into electrical energy through pressure and vibration. This study focuses on improving the conversion performance of poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) by incorporating graphene oxide (GO) and lead zirconate titanate (PZT). The dispersion of PZT and GO within the PVDF-HFP matrix was found to be homogeneous, resulting in high piezoelectric performance with an increase in the β-phase content. The thermal stability of the PVDF-HFP polymer also improved with the addition of PZT/GO. However, as the percentage of PZT/GO increased, the young's modulus of the composite decreased significantly. The developed composite demonstrated promising performance as a potential candidate for energy harvesting applications.

Keywords: energy harvesting, mechanical conversion, piezoelectric composite, solvent casting method

Procedia PDF Downloads 75
22888 A Descriptive Study on Comparison of Maternal and Perinatal Outcome of Twin Pregnancies Conceived Spontaneously and by Assisted Conception Methods

Authors: Aishvarya Gupta, Keerthana Anand, Sasirekha Rengaraj, Latha Chathurvedula

Abstract:

Introduction: Advances in assisted reproductive technology and increase in the proportion of infertile couples have both contributed to the steep increase in the incidence of twin pregnancies in past decades. Maternal and perinatal complications are higher in twins than in singleton pregnancies. Studies comparing the maternal and perinatal outcomes of ART twin pregnancies versus spontaneously conceived twin pregnancies report heterogeneous results making it unclear whether the complications are due to twin gestation per se or because of assisted reproductive techniques. The present study aims to compare both maternal and perinatal outcomes in twin pregnancies which are spontaneously conceived and after assisted conception methods, so that targeted steps can be undertaken in order to improve maternal and perinatal outcome of twins. Objectives: To study perinatal and maternal outcome in twin pregnancies conceived spontaneously as well as with assisted methods and compare the outcomes between the two groups. Setting: Women delivering at JIPMER (tertiary care institute), Pondicherry. Population: 380 women with twin pregnancies who delivered in JIPMER between June 2015 and March 2017 were included in the study. Methods: The study population was divided into two cohorts – one conceived by spontaneous conception and other by assisted reproductive methods. Association of various maternal and perinatal outcomes with the method of conception was assessed using chi square test or Student's t test as appropriate. Multiple logistic regression analysis was done to assess the independent association of assisted conception with maternal outcomes after adjusting for age, parity and BMI. Multiple logistic regression analysis was done to assess the independent association of assisted conception with perinatal outcomes after adjusting for age, parity, BMI, chorionicity, gestational age at delivery and presence of hypertension or gestational diabetes in the mother. A p value of < 0.05 was considered as significant. Result: There was increased proportion of women with GDM (21% v/s 4.29%) and premature rupture of membranes (35% v/s 22.85%) in the assisted conception group and more anemic women in the spontaneous group (71.27% v/s 55.1%). However assisted conception per se increased the incidence of GDM among twin gestations (OR 3.39, 95% CI 1.34 – 8.61) and did not influence any of the other maternal outcomes. Among the perinatal outcomes, assisted conception per se increased the risk of having very preterm (<32 weeks) neonates (OR 3.013, 95% CI 1.432 – 6.337). The mean birth weight did not significantly differ between the two groups (p = 0.429). Though there were higher proportion of babies admitted to NICU in the assisted conception group (48.48% v/s 36.43%), assisted conception per se did not increase the risk of admission to NICU (OR 1.23, 95% CI 0.76 – 1.98). There was no significant difference in perinatal mortality rates between the two groups (p = 0.829). Conclusion: Assisted conception per se increases the risk of developing GDM in women with twin gestation and increases the risk of delivering very preterm babies. Hence measures should be taken to ensure appropriate screening methods for GDM and suitable neonatal care in such pregnancies.

Keywords: assisted conception, maternal outcomes, perinatal outcomes, twin gestation

Procedia PDF Downloads 203
22887 The Effects of Nanoemulsions Based on Commercial Oils for the Quality of Vacuum-Packed Sea Bass at 2±2°C

Authors: Mustafa Durmuş, Yesim Ozogul, Esra Balıkcı, Saadet Gokdoğan, Fatih Ozogul, Ali Rıza Köşker, İlknur Yuvka

Abstract:

Food scientists and researchers have paid attention to develop new ways for improving the nutritional value of foods. The application of nanotechnology techniques to the food industry may allow the modification of food texture, taste, sensory attributes, coloring strength, processability, and stability during shelf life of products. In this research, the effects of nanoemulsions based on commercial oils for vacuum-packed sea bass fillets stored at 2±2°C were investigated in terms of the sensory, chemical (total volatile basic nitrogen (TVB-N), thiobarbituric acid (TBA), peroxide value (PV) and free fatty acids (FFA), pH, water holding capacity (WHC)) and microbiological qualities (total anaerobic bacteria and total lactic acid bacteria). Physical properties of emulsions (viscosity, the particle size of droplet, thermodynamic stability, refractive index, and surface tension) were determined. Nanoemulsion preparation method was based on high energy principle, with ultrasonic homojenizator. Sensory analyses of raw fish showed that the demerit points of the control group were found higher than those of treated groups. The sensory score (odour, taste and texture) of the cooked fillets decreased with storage time, especially in the control. Results obtained from chemical and microbiological analyses also showed that nanoemulsions significantly (p<0.05) decreased the values of biochemical parameters and growth of bacteria during storage period, thus improving quality of vacuum-packed sea bass.

Keywords: quality parameters, nanoemulsion, sea bass, shelf life, vacuum packing

Procedia PDF Downloads 454
22886 Effect of Number of Baffles on Pressure Drop and Heat Transfer in a Shell and Tube Heat Exchanger

Authors: A. Falavand Jozaei, A. Ghafouri, M. Mosavi Navaei

Abstract:

In this paper for a given heat duty, study of number of baffles on pressure drop and heat transfer is considered in a STHX (Shell and Tube Heat Exchanger) with single segmental baffles. The effect of number of baffles from 9 to 52 baffles (baffle spacing variations from 4 to 24 inches) over OHTC (Overall Heat Hransfer Coefficient) to pressure drop ratio (U/Δp ratio). The results show that U/Δp ratio is low when baffle spacing is minimum (4 inches) because pressure drop is high; however, heat transfer coefficient is very significant. Then, with the increase of baffle spacing, pressure drop rapidly decreases and OHTC also decreases, but the decrease of OHTC is lower than pressure drop, so (U/Δp) ratio increases. After increasing baffles more than 12 inches, variation in pressure drop is gradual and approximately constant and OHTC decreases; Consequently, U/Δp ratio decreases again. If baffle spacing reaches to 24 inches, STHX will have minimum pressure drop, but OHTC decreases, so required heat transfer surface increases and U/Δp ratio decreases. After baffle spacing more than 12 inches, variation of shell side pressure drop is negligible. So optimum baffle spacing is suggested between 8 to 12 inches (43 to 63 percent of inside shell diameter) for a sufficient heat duty and low pressure drop.

Keywords: shell and tube heat exchanger, single segmental baffle, overall heat transfer coefficient, pressure drop

Procedia PDF Downloads 536
22885 AI Peer Review Challenge: Standard Model of Physics vs 4D GEM EOS

Authors: David A. Harness

Abstract:

Natural evolution of ATP cognitive systems is to meet AI peer review standards. ATP process of axiom selection from Mizar to prove a conjecture would be further refined, as in all human and machine learning, by solving the real world problem of the proposed AI peer review challenge: Determine which conjecture forms the higher confidence level constructive proof between Standard Model of Physics SU(n) lattice gauge group operation vs. present non-standard 4D GEM EOS SU(n) lattice gauge group spatially extended operation in which the photon and electron are the first two trace angular momentum invariants of a gravitoelectromagnetic (GEM) energy momentum density tensor wavetrain integration spin-stress pressure-volume equation of state (EOS), initiated via 32 lines of Mathematica code. Resulting gravitoelectromagnetic spectrum ranges from compressive through rarefactive of the central cosmological constant vacuum energy density in units of pascals. Said self-adjoint group operation exclusively operates on the stress energy momentum tensor of the Einstein field equations, introducing quantization directly on the 4D spacetime level, essentially reformulating the Yang-Mills virtual superpositioned particle compounded lattice gauge groups quantization of the vacuum—into a single hyper-complex multi-valued GEM U(1) × SU(1,3) lattice gauge group Planck spacetime mesh quantization of the vacuum. Thus the Mizar corpus already contains all of the axioms required for relevant DeepMath premise selection and unambiguous formal natural language parsing in context deep learning.

Keywords: automated theorem proving, constructive quantum field theory, information theory, neural networks

Procedia PDF Downloads 174
22884 Evaluation Using a Bidirectional Microphone as a Pressure Pulse Wave Meter

Authors: Shunsuke Fujiwara, Takashi Kaburagi, Kazuyuki Kobayashi, Kajiro Watanabe, Yosuke Kurihara

Abstract:

This paper describes a novel sensor device, a pressure pulse wave meter, which uses a bidirectional condenser microphone. The microphone work as a microphone as well as a sensor with high gain over a wide frequency range; they are also highly reliable and economical. Currently aging is becoming a serious social issue in Japan causing increased medical expenses in the country. Hence, it is important for elderly citizens to check health condition at home, and to care the health conditions through daily monitoring. Given this circumstances, we developed a novel pressure pulse wave meter based on a bidirectional condenser microphone. This novel pressure pulse wave meter device is used as a measuring instrument of health conditions.

Keywords: bidirectional microphone, pressure pulse wave meter, health condition, novel sensor device

Procedia PDF Downloads 547
22883 High Pressure Processing of Jackfruit Bulbs: Effect on Color, Nutrient Profile and Enzyme Inactivation

Authors: Jyoti Kumari, Pavuluri Srinivasa Rao

Abstract:

Jackfruit (ArtocarpusheterophyllusL.) is an underutilized yet highly nutritious fruit with unique flavour, known for its therapeutic and culinary properties. Fresh jackfruit bulb has a very short shelf life due to high moisture and sugar content leading to microbial and enzymatic browning, hindering its consumer acceptability and marketability. An attempt has been made for the preservation of the ripe jackfruit bulbs, by the application of high pressure (HP) over a range of 200-500 MPa at ambient temperature for dwell times ranging from 5 to 20 min. The physicochemical properties of jackfruit bulbs such as the pH, TSS, and titrable acidity were not affected by the pressurization process. The ripening index of the fruit bulb also decreased following HP treatment. While the ascorbic acid and antioxidant activity of jackfruit bulb were well retained by high pressure processing (HPP), the total phenols and carotenoids showed a slight increase. The HPP significantly affected the colour and textural properties of jackfruit bulb. High pressure processing was highly effective in reducing the browning index of jackfruit bulbs in comparison to untreated bulbs. The firmness of the bulbs improved upon the pressure treatment with longer dwelling time. The polyphenol oxidase has been identified as the most prominent oxidative enzyme in the jackfruit bulb. The enzymatic activity of polyphenol oxidase and peroxidase were significantly reduced by up to 40% following treatment at 400 MPa/15 min. HPP of jackfruit bulbs at ambient temperatures is shown to be highly beneficial in improving the shelf stability, retaining its nutrient profile, color, and appearance while ensuring the maximum inactivation of the spoilage enzymes.

Keywords: antioxidant capacity, ascorbic acid, carotenoids, color, HPP-high pressure processing, jackfruit bulbs, polyphenol oxidase, peroxidase, total phenolic content

Procedia PDF Downloads 168
22882 Microwave-Assisted Extraction of Lycopene from Gac Arils (Momordica cochinchinensis (Lour.) Spreng)

Authors: Yardfon Tanongkankit, Kanjana Narkprasom, Nukrob Narkprasom, Khwanruthai Saiupparat, Phatthareeya Siriwat

Abstract:

Gac fruit (Momordica cochinchinensis (Lour.) Spreng) possesses high potential for health food as it contains high lycopene contents. The objective of this study was to optimize the extraction of lycopene from gac arils using the microwave extraction method. Response surface method was used to find the conditions that optimize the extraction of lycopene from gac arils. The parameters of extraction used in this study were extraction time (120-600 seconds), the solvent to sample ratio (10:1, 20:1, 30:1, 40:1 and 50:1 mL/g) and set microwave power (100-800 watts). The results showed that the microwave extraction condition at the extraction time of 360 seconds, the sample ratio of 30:1 mL/g and the microwave power of 450 watts were suggested since it exhibited the highest value of lycopene content of 9.86 mg/gDW. It was also observed that lycopene contents extracted from gac arils by microwave method were higher than that by the conventional method.

Keywords: conventional extraction, Gac arils, microwave-assisted extraction, Lycopene

Procedia PDF Downloads 382
22881 Myoelectric Analysis for the Assessment of Muscle Functions and Fatigue Monitoring of Upper Extremity for Stroke Patients Performing Robot-Assisted Bilateral Training

Authors: Hsiao-Lung Chan, Ching-Yi Wu, Yan-Zou Lin, Yo Chiao, Ya-Ju Chang

Abstract:

Robot-assisted bilateral arm training has demonstrated useful to improve motor control in stroke patients and save human resources. In clinics, the efficiency of this treatment is mostly performed by comparing functional scales before and after rehabilitation. However, most of these assessments are based on behavior evaluation. The underlying improvement of muscle activation and coordination is unknown. Moreover, stroke patients are easier to have muscle fatigue under robot-assisted rehabilitation due to the weakness of muscles. This safety issue is still less studied. In this study, EMG analysis was applied during training. Our preliminary results showed the co-contraction index and co-contraction area index can delineate the improved muscle coordination of biceps brachii vs. flexor carpiradialis. Moreover, the smoothed, normalized cycle-by-cycle median frequency of left and right extensor carpiradialis decreased as the training progress, implying the occurrence of muscle fatigue.

Keywords: robot-assisted rehabilitation, strokes, muscle coordination, muscle fatigue

Procedia PDF Downloads 472
22880 Adsorption Studies of Methane on Zeolite NaX, LiX, KX at High Pressures

Authors: El Hadi Zouaoui, Djamel Nibou, Mohamed Haddouche, Wan Azlina Wan Ab Karim Ghani, Samira Amokrane

Abstract:

In this study, CH₄ adsorption isotherms on NaX or Faujasite X and exchanged zeolites with Li⁺(LiX), and K⁺(KX) at different temperatures (298, 308, 323 and 353 K) has been investigated, using high pressure (3 MPa (30 bar)) thermo-gravimetric analyser. The experimental results were then validated using several isothermal kinetics models, namely Langmuir, Toth, and Marczewski-Jaroniec, followed by a calculation of the error coefficients between the experimental and theoretical results. It was found that the CH₄ adsorption isotherms are characterized by a strong increase in adsorption at low pressure and a tendency towards a high pressure limit value Qₘₐₓ. The size and position of the exchanged cations, the spherical shape of methane, the specific surface, and the volume of the pores revealed the most important influence parameters for this study. These results revealed that the experimentation and the modeling, well correlated with Marczewski-Jaroniec, Toth, and gave the best results whatever the temperature and the material used.

Keywords: CH₄ adsorption, exchange cations, exchanged zeolite, isotherm study, NaX zeolite

Procedia PDF Downloads 245
22879 Effects of Injection Conditions on Flame Structures in Gas-Centered Swirl Coaxial Injector

Authors: Wooseok Song, Sunjung Park, Jongkwon Lee, Jaye Koo

Abstract:

The objective of this paper is to observe the effects of injection conditions on flame structures in gas-centered swirl coaxial injector. Gaseous oxygen and liquid kerosene were used as propellants. For different injection conditions, two types of injector, which only differ in the diameter of the tangential inlet, were used in this study. In addition, oxidizer injection pressure was varied to control the combustion chamber pressure in different types of injector. In order to analyze the combustion instability intensity, the dynamic pressure was measured in both the combustion chamber and propellants lines. With the increase in differential pressure between the propellant injection pressure and the combustion chamber pressure, the combustion instability intensity increased. In addition, the flame structure was recorded using a high-speed camera to detect CH* chemiluminescence intensity. With the change in the injection conditions in the gas-centered swirl coaxial injector, the flame structure changed.

Keywords: liquid rocket engine, flame structure, combustion instability, dynamic pressure

Procedia PDF Downloads 225
22878 Development of Ceramic Spheres Buoyancy Modules for Deep-Sea Oil Exploration

Authors: G. Blugan, B. Jiang, J. Thornberry, P. Sturzenegger, U. Gonzenbach, M. Misson, D. Cartlidge, R. Stenerud, J. Kuebler

Abstract:

Low-cost ceramic spheres were developed and manufactured from the engineering ceramic aluminium oxide. Hollow spheres of 50 mm diameter with a wall thickness of 0.5-1.0 mm were produced via an adapted slip casting technique. It was possible to produce the spheres with good repeatability and with no defects or failures in the spheres due to the manufacturing process. The spheres were developed specifically for use in buoyancy devices for deep-sea exploration conditions at depths of 3000 m below sea level. The spheres with a 1.0 mm wall thickness exhibit a buoyancy of over 54% while the spheres with a 0.5 mm wall thickness exhibit a buoyancy of over 73%. The mechanical performance of the spheres was confirmed by performing a hydraulic burst pressure test on individual spheres. With a safety factor of 3, all spheres with 1.0 mm wall thickness survived a hydraulic pressure of greater than 150 MPa which is equivalent to a depth of more than 5000 m below sea level. The spheres were then incorporated into a buoyancy module. These hollow aluminium oxide ceramic spheres offer an excellent possibility of deep-sea exploration to depths greater than the currently used technology.

Keywords: buoyancy, ceramic spheres, deep-sea, oil exploration

Procedia PDF Downloads 409
22877 The Effect of Volume Fraction of Nano-Alumina Strengthening on AC4B Composite Characteristics through the Stir Casting Method as a Material Brake Shoe

Authors: Benny Alexander, Ikhlashia N. Fadhilah, Muhammad R. Pasha, Michelle Julia, Anne Z. Syahrial

Abstract:

Brake shoe is a component that serves to reduce speed or stop the train's speed by utilizing the friction force. Generally, the material used as a brake shoe is cast iron, where cast iron itself is a heavy, expensive, and easily worn material. Aluminum matrix composites are one of candidates for the cast iron replacement material as the basic material for brake shoe. The matrix in the composite used is Aluminum AC4B. Reinforcement used in aluminum matrix composites is nano-alumina, where the use of nano-alumina of 0.25%, 0.3%, 0.35%, 0.4%, and 0.5% volume fraction will be tested. The sample is made using the stir casting method; then, it will be tested mechanically. The use of nano-alumina as a reinforcement will increase the strength of the matrix. SEM (scanning electron microscopy) testing is used to test the distribution of reinforcing particles due to stirring. Therefore, the addition of nano-alumina will improve AC4B aluminum matrix composites.

Keywords: aluminium matrix composites, brake shoe application, stir casting, nano-alumina

Procedia PDF Downloads 130
22876 Thermally Stable Nanocrystalline Aluminum Alloys Processed by Mechanical Alloying and High Frequency Induction Heat Sintering

Authors: Hany R. Ammar, Khalil A. Khalil, El-Sayed M. Sherif

Abstract:

The as-received metal powders were used to synthesis bulk nanocrystalline Al; Al-10%Cu; and Al-10%Cu-5%Ti alloys using mechanical alloying and high frequency induction heat sintering (HFIHS). The current study investigated the influence of milling time and ball-to-powder (BPR) weight ratio on the microstructural constituents and mechanical properties of the processed materials. Powder consolidation was carried out using a high frequency induction heat sintering where the processed metal powders were sintered into a dense and strong bulk material. The sintering conditions applied in this process were as follow: heating rate of 350°C/min; sintering time of 4 minutes; sintering temperature of 400°C; applied pressure of 750 Kgf/cm2 (100 MPa); cooling rate of 400°C/min and the process was carried out under vacuum of 10-3 Torr. The powders and the bulk samples were characterized using XRD and FEGSEM techniques. The mechanical properties were evaluated at various temperatures of 25°C, 100°C, 200°C, 300°C and 400°C to study the thermal stability of the processed alloys. The bulk nanocrystalline Al; Al-10%Cu; and Al-10%Cu-5%Ti alloys displayed extremely high hardness values even at elevated temperatures. The Al-10%Cu-5%Ti alloy displayed the highest hardness values at room and elevated temperatures which are related to the presence of Ti-containing phases such as Al3Ti and AlCu2Ti, these phases are thermally stable and retain the high hardness values at elevated temperatures up to 400ºC.

Keywords: nanocrystalline aluminum alloys, mechanical alloying, hardness, elevated temperatures

Procedia PDF Downloads 449
22875 Direct Measurement of Pressure and Temperature Variations During High-Speed Friction Experiments

Authors: Simon Guerin-Marthe, Marie Violay

Abstract:

Thermal Pressurization (TP) has been proposed as a key mechanism involved in the weakening of faults during dynamic ruptures. Theoretical and numerical studies clearly show how frictional heating can lead to an increase in pore fluid pressure due to the rapid slip along faults occurring during earthquakes. In addition, recent laboratory studies have evidenced local pore pressure or local temperature variation during rotary shear tests, which are consistent with TP theoretical and numerical models. The aim of this study is to complement previous ones by measuring both local pore pressure and local temperature variations in the vicinity of a water-saturated calcite gouge layer subjected to a controlled slip velocity in direct double shear configuration. Laboratory investigation of TP process is crucial in order to understand the conditions at which it is likely to become a dominant mechanism controlling dynamic friction. It is also important in order to understand the timing and magnitude of temperature and pore pressure variations, to help understanding when it is negligible, and how it competes with other rather strengthening-mechanisms such as dilatancy, which can occur during rock failure. Here we present unique direct measurements of temperature and pressure variations during high-speed friction experiments under various load point velocities and show the timing of these variations relatively to the slip event.

Keywords: thermal pressurization, double-shear test, high-speed friction, dilatancy

Procedia PDF Downloads 58
22874 Pilot-Assisted Direct-Current Biased Optical Orthogonal Frequency Division Multiplexing Visible Light Communication System

Authors: Ayad A. Abdulkafi, Shahir F. Nawaf, Mohammed K. Hussein, Ibrahim K. Sileh, Fouad A. Abdulkafi

Abstract:

Visible light communication (VLC) is a new approach of optical wireless communication proposed to support the congested radio frequency (RF) spectrum. VLC systems are combined with orthogonal frequency division multiplexing (OFDM) to achieve high rate transmission and high spectral efficiency. In this paper, we investigate the Pilot-Assisted Channel Estimation for DC biased Optical OFDM (PACE-DCO-OFDM) systems to reduce the effects of the distortion on the transmitted signal. Least-square (LS) and linear minimum mean-squared error (LMMSE) estimators are implemented in MATLAB/Simulink to enhance the bit-error-rate (BER) of PACE-DCO-OFDM. Results show that DCO-OFDM system based on PACE scheme has achieved better BER performance compared to conventional system without pilot assisted channel estimation. Simulation results show that the proposed PACE-DCO-OFDM based on LMMSE algorithm can more accurately estimate the channel and achieves better BER performance when compared to the LS based PACE-DCO-OFDM and the traditional system without PACE. For the same signal to noise ratio (SNR) of 25 dB, the achieved BER is about 5×10-4 for LMMSE-PACE and 4.2×10-3 with LS-PACE while it is about 2×10-1 for system without PACE scheme.

Keywords: channel estimation, OFDM, pilot-assist, VLC

Procedia PDF Downloads 174
22873 A Study of the Growth of Single-Phase Mg0.5Zn0.5O Films for UV LED

Authors: Hong Seung Kim, Chang Hoi Kim, Lili Yue

Abstract:

Single-phase, high band gap energy Zn0.5Mg0.5O films were grown under oxygen pressure, using pulse laser deposition with a Zn0.5Mg0.5O target. Structural characterization studies revealed that the crystal structures of the ZnX-1MgXO films could be controlled via changes in the oxygen pressure. TEM analysis showed that the thickness of the deposited Zn1-xMgxO thin films was 50–75 nm. As the oxygen pressure increased, we found that one axis of the crystals did not show a very significant increase in the crystallization compared with that observed at low oxygen pressure. The X-ray diffraction peak intensity for the hexagonal-ZnMgO (002) plane increased relative to that for the cubic-ZnMgO (111) plane. The corresponding c-axis of the h-ZnMgO lattice constant increased from 5.141 to 5.148 Å, and the a-axis of the c-ZnMgO lattice constant decreased from 4.255 to 4.250 Å. EDX analysis showed that the Mg content in the mixed-phase ZnMgO films decreased significantly, from 54.25 to 46.96 at.%. As the oxygen pressure was increased from 100 to 150 mTorr, the absorption edge red-shifted from 3.96 to 3.81 eV; however, a film grown at the highest oxygen pressure tested here (200 mTorr).

Keywords: MgO, UV LED, ZnMgO, ZnO

Procedia PDF Downloads 400
22872 Computer Assisted Strategies Help to Pharmacist

Authors: Komal Fizza

Abstract:

All around the world in every field professionals are taking great support from their computers. Computer assisted strategies not only increase the efficiency of the professionals but also in case of healthcare they help in life-saving interventions. The background of this current research is aimed towards two things; first to find out if computer assisted strategies are useful for Pharmacist for not and secondly how much these assist a Pharmacist to do quality interventions. Shifa International Hospital is a 500 bedded hospital, and it is running Antimicrobial Stewardship, during their stewardship rounds pharmacists observed that a lot of wrong doses of antibiotics were coming at times those were being overlooked by the other pharmacist even. So, with the help of MIS team the patients were categorized into adult and peads depending upon their age. Minimum and maximum dose of every single antibiotic present in the pharmacy that could be dispensed to the patient was developed. These were linked to the order entry window. So whenever pharmacist would type any order and the dose would be below or above the therapeutic limit this would give an alert to the pharmacist. Whenever this message pop-up this was recorded at the back end along with the antibiotic name, pharmacist ID, date, and time. From 14th of January 2015 and till 14th of March 2015 the software stopped different users 350 times. Out of this 300 were found to be major errors which if reached to the patient could have harmed them to the greater extent. While 50 were due to typing errors and minor deviations. The pilot study showed that computer assisted strategies can be of great help to the pharmacist. They can improve the efficacy and quality of interventions.

Keywords: antibiotics, computer assisted strategies, pharmacist, stewardship

Procedia PDF Downloads 485
22871 High-Pressure Polymorphism of 4,4-Bipyridine Hydrobromide

Authors: Michalina Aniola, Andrzej Katrusiak

Abstract:

4,4-Bipyridine is an important compound often used in chemical practice and more recently frequently applied for designing new metal organic framework (MoFs). Here we present a systematic high-pressure study of its hydrobromide salt. 4,4-Bipyridine hydrobromide monohydrate, 44biPyHBrH₂O, at ambient-pressure is orthorhombic, space group P212121 (phase a). Its hydrostatic compression shows that it is stable to 1.32 GPa at least. However, the recrystallization above 0.55 GPa reveals a new hidden b-phase (monoclinic, P21/c). Moreover, when the 44biPyHBrH2O is heated to high temperature the chemical reactions of this compound in methanol solution can be observed. High-pressure experiments were performed using a Merrill-Bassett diamond-anvil cell (DAC), modified by mounting the anvils directly on the steel supports, and X-ray diffraction measurements were carried out on a KUMA and Excalibur diffractometer equipped with an EOS CCD detector. At elevated pressure, the crystal of 44biPyHBrH₂O exhibits several striking and unexpected features. No signs of instability of phase a were detected to 1.32 GPa, while phase b becomes stable at above 0.55 GPa, as evidenced by its recrystallizations. Phases a and b of 44biPyHBrH2O are partly isostructural: their unit-cell dimensions and the arrangement of ions and water molecules are similar. In phase b the HOH-Br- chains double the frequency of their zigzag motifs, compared to phase a, and the 44biPyH+ cations change their conformation. Like in all monosalts of 44biPy determined so far, in phase a the pyridine rings are twisted by about 30 degrees about bond C4-C4 and in phase b they assume energy-unfavorable planar conformation. Another unusual feature of 44biPyHBrH2O is that all unit-cell parameters become longer on the transition from phase a to phase b. Thus the volume drop on the transition to high-pressure phase b totally depends on the shear strain of the lattice. Higher temperature triggers chemical reactions of 44biPyHBrH2O with methanol. When the saturated methanol solution compound precipitated at 0.1 GPa and temperature of 423 K was required to dissolve all the sample, the subsequent slow recrystallization at isochoric conditions resulted in disalt 4,4-bipyridinium dibromide. For the 44biPyHBrH2O sample sealed in the DAC at 0.35 GPa, then dissolved at isochoric conditions at 473 K and recrystallized by slow controlled cooling, a reaction of N,N-dimethylation took place. It is characteristic that in both high-pressure reactions of 44biPyHBrH₂O the unsolvated disalt products were formed and that free base 44biPy and H₂O remained in the solution. The observed reactions indicate that high pressure destabilized ambient-pressure salts and favors new products. Further studies on pressure-induced reactions are carried out in order to better understand the structural preferences induced by pressure.

Keywords: conformation, high-pressure, negative area compressibility, polymorphism

Procedia PDF Downloads 242
22870 Sustainable Lessons learnt from the attitudes of Language Instructors towards Computer Assisted Language Teaching (CALT)

Authors: Theophilus Adedokun, Sylvia Zulu, Felix Awung, Sam Usadolo

Abstract:

The proliferation of technology into teaching process has brought about transformation into the field of education. Language teaching is not left behind from this tremendous transformation which has drastically altered the teaching of language. It is, however, appalling that some language instructors seem to possess negative attitudes toward the use of technology in language teaching, which in this study is referred to as Computer Assisted Language Teaching (CALT). The purpose of this study, therefore, is to explore sustainable lesson that can be learnt from the attitudes of language instructors towards language teaching in some public universities. The knowledge gained from this study could inform and advance the use of Computer Assisted Language Teaching. This study considers the historical progression of CALT and recommends that a fundamental approach is required for institutions to develop and advance the use of CALT for teaching. A review of sustainable lessons learnt from the attitudes of language instructors towards CALT are provided, and the CALT experience of 3 institutions are described. Drawing from this succinct description, this study makes recommendations on how operative CALT could be executed on a personal and institutional basis.

Keywords: attitudes, language instructors, sustainable lessons, computer assisted language teaching

Procedia PDF Downloads 79
22869 Wear Diagnosis of Diesel Engine Helical Gear

Authors: Surjit Angra, Gajanan Rane, Vinod Kumar, Sushma Rani

Abstract:

This paper presents metallurgical investigation of failed helical gear of diesel engine gear box used in a car. The failure had occurred near the bottomland of the tooth spacing. The failed surface was studied under Scanning Electron Microscope (SEM) and also visually investigated. The images produced through SEM at various magnifications were studied. Detailed metallurgical study indicates that failure was due to foreign material inclusion which is a casting defect. Further study also revealed pitting, spalling and inter-granular fracture as the causes of gear failure.

Keywords: helical gear, scanning electron microscope, casting defect, pitting

Procedia PDF Downloads 447