Search results for: Kuo Chieh Chao
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 213

Search results for: Kuo Chieh Chao

3 Morphotropic Phase Boundary in Ferromagnets: Unusual Magnetoelastic Behavior In Tb₁₋ₓNdₓCo₂

Authors: Adil Murtaza, Muhammad Tahir Khan, Awais Ghani, Chao Zhou, Sen Yang, Xiaoping Song

Abstract:

The morphotropic phase boundary (MPB); a boundary between two different crystallographic symmetries in the composition–temperature phase diagram has been widely studied in ferroelectrics and recently has drawn interest in ferromagnets for obtaining enhanced large field-induced strain. At MPB, the system gets a compressed free energy state, which allows the polarization to freely rotate and hence results in a high magnetoelastic response (e.g., high magnetization, low coercivity, and large magnetostriction). Based on the same mechanism, we designed MPB in a ferromagnetic Tb₁₋ₓNdₓCo₂ system. The temperature-dependent magnetization curves showed spin reorientation (SR); which can be explained by a two-sublattice model. Contrary to previously reported MPB involved ferromagnetic systems, the MPB composition of Tb₀.₃₅Nd₀.₆₅Co₂ exhibits a low saturation magnetization (MS), indicating a compensation of the Tb and Nd magnetic moments at MPB. The coercive field (HC) under a low magnetic field and first anisotropy constant (K₁) shows a minimum value at MPB composition of x=0.65. A detailed spin configuration diagram is provided for the Tb₁₋ₓNdₓCo₂ around the composition for the anisotropy compensation; this can guide the development of novel magnetostrictive materials. The anisotropic magnetostriction (λS) first decreased until x=0.8 and then continuously increased in the negative direction with further increase of Nd concentration. In addition, the large ratio between magnetostriction and the absolute values of the first anisotropy constant (λS/K₁) appears at MPB, indicating that Tb₀.₃₅Nd₀.₆₅Co₂ has good magnetostrictive properties. Present work shows an anomalous type of MPB in ferromagnetic materials, revealing that MPB can also lead to a weakening of magnetoelastic behavior as shown in the ferromagnetic Tb₁₋ₓNdₓCo₂ system. Our work shows the universal presence of MPB in ferromagnetic materials and suggests the differences between different ferromagnetic MPB systems that are important for substantial improvement of magnetic and magnetostrictive properties. Based on the results of this study, similar MPB effects might be achieved in other ferroic systems that can be used for technological applications. The finding of magnetic MPB in the ferromagnetic system leads to some important significances. First, it provides a better understanding of the fundamental concept of spin reorientation transitions (SRT) like ferro-ferro transitions are not only reorientation of magnetization but also crystal symmetry change upon magnetic ordering. Second, the flattened free energy corresponding to a low energy barrier for magnetization rotation and enhanced magnetoelastic response near MPB. Third, to attain large magnetostriction with MPB approach two terminal compounds have different easy magnetization directions below Curie temperature Tc in order to accomplish the weakening of magnetization anisotropy at MPB (as in ferroelectrics), thus easing the magnetic domain switching and the lattice distortion difference between two terminal compounds should be large enough, e.g., lattice distortion of R symmetry ˃˃ lattice distortion of T symmetry). So that the MPB composition agrees to a nearly isotropic state along with large ‘net’ lattice distortion, which is revealed in a higher value of magnetostriction.

Keywords: magnetization, magnetostriction, morphotropic phase boundary (MPB), phase transition

Procedia PDF Downloads 146
2 Prevalence of Occupational Asthma Diagnosed by Specific Challenge Test in 5 Different Working Environments in Thailand

Authors: Sawang Saenghirunvattana, Chao Saenghirunvattana, Maria Christina Gonzales, Wilai Srimuk, Chitchamai Siangpro, Kritsana Sutthisri

Abstract:

Introduction: Thailand is one of the fastest growing countries in Asia. It has emerged from agricultural to industrialized economy. Work places have shifted from farms to factories, offices and streets were employees are exposed to certain chemicals and pollutants causing occupational diseases particularly asthma. Work-related diseases are major concern and many studies have been published to demonstrate certain professions and their exposures that elevate the risk of asthma. Workers who exhibit coughing, wheezing and difficulty of breathing are brought to a health care setting where Pulmonary Function Test (PFT) is performed and based from results, they are then diagnosed of asthma. These patients, known to have occupational asthma eventually get well when removed from the exposure of the environment. Our study, focused on performing PFT or specific challenge test in diagnosing workers of occupational asthma with them executing the test within their workplace, maintaining the environment and their daily exposure to certain levels of chemicals and pollutants. This has provided us with an understanding and reliable diagnosis of occupational asthma. Objective: To identify the prevalence of Thai workers who develop asthma caused by exposure to pollutants and chemicals from their working environment by conducting interview and performing PFT or specific challenge test in their work places. Materials and Methods: This study was performed from January-March 2015 in Bangkok, Thailand. The percentage of abnormal symptoms of 940 workers in 5 different areas (factories of plastic, fertilizer, animal food, office and streets) were collected through a questionnaire. The demographic information, occupational history, and the state of health were determined using a questionnaire and checklists. PFT was executed in their work places and results were measured and evaluated. Results: Pulmonary Function test was performed by 940 participants. The specific challenge test was done in factories of plastic, fertilizer, animal food, office environment and on the streets of Thailand. Of the 100 participants working in the plastic industry, 65% complained of having respiratory symptoms. None of them had an abnormal PFT. From the participants who worked with fertilizers and are exposed to sulfur dioxide, out of 200 participants, 20% complained of having symptoms and 8% had abnormal PFT. The 300 subjects working with animal food reported that 45% complained of respiratory symptoms and 15% had abnormal PFT results. From the office environment where there is indoor pollution, Out of 140 subjects, 7% had symptoms and 4% had abnormal PFT. The 200 workers exposed to traffic pollution, 24% reported respiratory symptoms and 12% had abnormal PFT. Conclusion: We were able to identify and diagnose participants of occupational asthma through their abnormal lung function test done at their work places. The chemical agents and exposures were determined therefore effective management of workers with occupational asthma were advised to avoid further exposure for better chances of recovery. Further studies identifying the risk factors and causative agents of asthma in workplaces should be developed to encourage interventional strategies and programs that will prevent occupation related diseases particularly asthma.

Keywords: occupational asthma, pulmonary function test, specific challenge test, Thailand

Procedia PDF Downloads 304
1 Wind Tunnel Tests on Ground-Mounted and Roof-Mounted Photovoltaic Array Systems

Authors: Chao-Yang Huang, Rwey-Hua Cherng, Chung-Lin Fu, Yuan-Lung Lo

Abstract:

Solar energy is one of the replaceable choices to reduce the CO2 emission produced by conventional power plants in the modern society. As an island which is frequently visited by strong typhoons and earthquakes, it is an urgent issue for Taiwan to make an effort in revising the local regulations to strengthen the safety design of photovoltaic systems. Currently, the Taiwanese code for wind resistant design of structures does not have a clear explanation on photovoltaic systems, especially when the systems are arranged in arrayed format. Furthermore, when the arrayed photovoltaic system is mounted on the rooftop, the approaching flow is significantly altered by the building and led to different pressure pattern in the different area of the photovoltaic system. In this study, L-shape arrayed photovoltaic system is mounted on the ground of the wind tunnel and then mounted on the building rooftop. The system is consisted of 60 PV models. Each panel model is equivalent to a full size of 3.0 m in depth and 10.0 m in length. Six pressure taps are installed on the upper surface of the panel model and the other six are on the bottom surface to measure the net pressures. Wind attack angle is varied from 0° to 360° in a 10° interval for the worst concern due to wind direction. The sampling rate of the pressure scanning system is set as high enough to precisely estimate the peak pressure and at least 20 samples are recorded for good ensemble average stability. Each sample is equivalent to 10-minute time length in full scale. All the scale factors, including timescale, length scale, and velocity scale, are properly verified by similarity rules in low wind speed wind tunnel environment. The purpose of L-shape arrayed system is for the understanding the pressure characteristics at the corner area. Extreme value analysis is applied to obtain the design pressure coefficient for each net pressure. The commonly utilized Cook-and-Mayne coefficient, 78%, is set to the target non-exceedance probability for design pressure coefficients under Gumbel distribution. Best linear unbiased estimator method is utilized for the Gumbel parameter identification. Careful time moving averaging method is also concerned in data processing. Results show that when the arrayed photovoltaic system is mounted on the ground, the first row of the panels reveals stronger positive pressure than that mounted on the rooftop. Due to the flow separation occurring at the building edge, the first row of the panels on the rooftop is most in negative pressures; the last row, on the other hand, shows positive pressures because of the flow reattachment. Different areas also have different pressure patterns, which corresponds well to the regulations in ASCE7-16 describing the area division for design values. Several minor observations are found according to parametric studies, such as rooftop edge effect, parapet effect, building aspect effect, row interval effect, and so on. General comments are then made for the proposal of regulation revision in Taiwanese code.

Keywords: aerodynamic force coefficient, ground-mounted, roof-mounted, wind tunnel test, photovoltaic

Procedia PDF Downloads 138