Search results for: NIST test suite
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 9259

Search results for: NIST test suite

9139 Evaluation of Mutagenic and Antimutagenic Activities of Some Biological Active Benzoxazoles in the Ames Test

Authors: Özlem Arpacı, Zeliha Soysal, Nuran Diril

Abstract:

Benzoxazoles are heterocyclic compounds that have a fused benzene and an oxazole ring. These heterocyclic compounds are reported to have antibacterial, antitubercular, antifungal, antiviral, antioxidant and anticancer activities. In this study, some benzoxazole derivatives that have broad antimicrobial and potent antitumoral activities, are investigated their mutagenic activities with using the Ames Test. The Ames test was conducted using Salmonella typhimurium TA98, TA100 and TA102 tester strains in the standard plate incorporation assay in the absence of liver S9 fraction. The results are evaluated using SPSS and none of the benzoxazole derivatives showed mutagenic activity using the Ames test in the absence of S9 liver fraction.

Keywords: benzoxazoles, ames test, mutagenic activity, antimutagenic activity, antitumoral activity

Procedia PDF Downloads 338
9138 Khon Kaen University Family Health Assessment Tool Training Program on Primary Care Unit Nurses’ Skills

Authors: Suwarno, D. Jongudomkarn

Abstract:

Family Health Assessment (FHA) is a key process to identify the family health needs, family health problems, and family health history. Assessing the family health is not only from the assessment tool but also from health care provider especially Nurse. Nurses’ have duties to assess the family as holistic view and they have to increase their capacities (knowledge, skills and experiences) in FHA. Thus, the continuing nursing education-training program on using the KKU FHA Tool was aimed to enhance the participant nurses’ capacities in (FHA) based on such tool. The aim of this study was to evaluate the KKU FHA Tool training program on PCU nurses’ capacity before and after training program in Primary Care Unit Bantul, Yogyakarta. The Quasi-Experiment with one group pre-, post-test design as a research design with convenient sampling technique and one group pre- post test formula for Nurses who work in Six PCU Bantul, Yogyakarta as much as fourteen respondents. The research processes were used training program with module, video and handbook KKU FHA Tool, KKU FHA tool form and capacities questionnaires. It was analyzed by descriptive data, Kolmogorov-Smirnov and Paired Sample t-test. The overall comparing analysis of paired sample t-test revealed that the mean values of pre-test were 3.35 with SD 0.417, post-test was 3.86 with SD 0.154 and post-test in later two weeks was 4.00 with SD 0.243. It was found that the p value of among the pre-test, the intermediate post-test and the post–test in later two weeks were 0.000. The p value of the intermediate post-test and post-test in later two weeks was 0.053. KKU FHA Tool training program in PCU Bantul Yogyakarta was enhanced the participant nurses’ capacities significantly. In conclusion, we are recommending KKU FHA Tool forms have to develop and implement with qualitative research as complementary data in PCU Bantul Yogyakarta by Focus Group Discussion.

Keywords: family health assessment, KKU FHA tool, training program, nurses capacities

Procedia PDF Downloads 375
9137 A Socio-Technical Approach to Cyber-Risk Assessment

Authors: Kitty Kioskli, Nineta Polemi

Abstract:

Evaluating the levels of cyber-security risks within an enterprise is most important in protecting its information system, services and all its digital assets against security incidents (e.g. accidents, malicious acts, massive cyber-attacks). The existing risk assessment methodologies (e.g. eBIOS, OCTAVE, CRAMM, NIST-800) adopt a technical approach considering as attack factors only the capability, intention and target of the attacker, and not paying attention to the attacker’s psychological profile and personality traits. In this paper, a socio-technical approach is proposed in cyber risk assessment, in order to achieve more realistic risk estimates by considering the personality traits of the attackers. In particular, based upon principles from investigative psychology and behavioural science, a multi-dimensional, extended, quantifiable model for an attacker’s profile is developed, which becomes an additional factor in the cyber risk level calculation.

Keywords: attacker, behavioural models, cyber risk assessment, cybersecurity, human factors, investigative psychology, ISO27001, ISO27005

Procedia PDF Downloads 158
9136 Comparative Study on Fire Safety Evaluation Methods for External Cladding Systems: ISO 13785-2 and BS 8414

Authors: Kyungsuk Cho, H. Y. Kim, S. U. Chae, J. H. Choi

Abstract:

Technological development has led to the construction of super-tall buildings and insulators are increasingly used as exterior finishing materials to save energy. However, insulators are usually combustible and vulnerable to fire. Fires like that at Wooshin Golden Suite Building in Busan, Korea in 2010 and that at CCTV Building in Beijing, China are the major examples of fire spread accelerated by combustible insulators. The exterior finishing materials of a high-rise building are not made of insulators only, but they are integrated with the building’s external cladding system. There is a limit in evaluating the fire safety of a cladding system with a single small-unit material such as a cone calorimeter. Therefore, countries provide codes to evaluate the fire safety of exterior finishing materials using full-scale tests. This study compares and to examine the applicability of the methods to Korea. Standard analysis showed differences in the type and size of fire sources and duration and exterior finishing materials also differed in size. In order to confirm the differences, fire tests were conducted on identical external cladding systems to compare fire safety. Although the exterior finishing materials were identical, varying degrees of fire spread were observed, which could be considered as differences in the type and size of the fire sources and duration. Therefore, it is deduced that extended studies should be conducted before the evaluation methods and standards are employed in Korea. The two standards for evaluating fire safety provided different results. Peak heat release rate was 5.5MW in ISO method and 3.0±0.5MW in BS method. Peak heat release rate in ISO method continued for 15 minutes. Fire ignition, growth, full development and decay evolved for 30 minutes in BS method where wood cribs were used as fire sources. Therefore, follow-up studies should be conducted to determine which of the two standards provides fire sources that approximate the size of flames coming out from the openings or those spreading to the outside when a fire occurs at a high-rise building.

Keywords: external cladding systems, fire safety evaluation, ISO 13785-2, BS 8414

Procedia PDF Downloads 237
9135 Using Multiple Intelligences Theory to Develop Thai Language Skill

Authors: Bualak Naksongkaew

Abstract:

The purposes of this study were to compare pre- and post-test achievement of Thai language skills. The samples consisted of 40 tenth grader of Secondary Demonstration School of Suan Sunandha Rajabhat University in the first semester of the academic year 2010. The researcher prepared the Thai lesson plans, the pre- and post-achievement test at the end program. Data analyses were carried out using means, standard deviations and descriptive statistics, independent samples t-test analysis for comparison pre- and post-test. The study showed that there were a statistically significant difference at α= 0.05; therefore the use multiple intelligences theory can develop Thai languages skills. The results after using the multiple intelligences theory for Thai lessons had higher level than standard.

Keywords: multiple intelligences theory, Thai language skills, development, pre- and post-test achievement

Procedia PDF Downloads 421
9134 Setting the Acceleration Test Conditions for Establishing the Expiration Date of Probiotics

Authors: Myoyeon Kim

Abstract:

The number of probiotics is various from product to product. The product must contain as many bacteria as the number of bacteria that claim because it greatly affects consumers' choices. It is very difficult to determine the number of viable bacteria with tests that proceed during the product development stage because the shelf life of lactic acid bacteria is mostly 18 to 24 months, and product development proceeds much faster than this. To predict the shelf life, a method of checking the number of viable bacteria was studied by shortening the time. The experiment was conducted with a total of 7 products including our products. The ongoing test stored at room temperature, the acceleration test stored at 30°C and 40°C were performed, and the number of bacteria was measured every two weeks. The number of viable bacteria stored at 30°C for 12 weeks was similar to the ongoing test when the shelf life was imminent. If it took more than 12 weeks, the product development schedule was postponed, so acceleration had no meaning. It was found that products stored at 40°C were unsuitable as acceleration test temperatures because the bacteria were almost killed within 4 to 8 weeks.

Keywords: probiotics, shelf-life, acceleration test, lactobacillus

Procedia PDF Downloads 26
9133 The Improving Students' Ability on Phrasal Verbs through Movie with the 10th Grade Students of Demonstration School of Khon Kaen University

Authors: Nujuree Sukasame

Abstract:

This paper is entitled"The Improving Students on Phrasal Verbs Through movie with the grade10th Grade Students of Demonstration School of Khon Kaen University in the Academic year 2014..The sample group consitsed of30 the Grade students ofDemonstration School randomized by Purposive Sampling. The purpose of this research is to improve students"ability in phrasal verbs through movie at prescribe criteria 70%.It was used as the researcher treatment to encourage students to develope phrasal verbs on movie.Two types of instruments used were phrasal verbs test and attitude questionnaires.The research desige used was One grop Pre-test Post-test Design methode and analyzed by percentage and means. The result showed that in the pre-test and the post-test the mean scores were10.30% and 26% respectively.The result of t-test indicated statistically t=-3.077.It significant difference was at0.1.From the above result, It is noticed that the students"ability on phrasal verbs was improved significantly through movie.

Keywords: the improving, phrasal verbs, movie, students

Procedia PDF Downloads 426
9132 Assessment of Estrogenic Contamination and Potential Risk in Taihu Lake, China

Authors: Guanghua Lu, Zhenhua Yan

Abstract:

To investigate the estrogenic contamination and potential risk of Taihu Lake, eight active biomonitoring points in the northern section of Taihu Lake were set up and located in Wangyuhe River outlet (P1), Gonghu Bay (P2 and P3), Meiliang Bay (P4 and P5), Zhushan Bay (P6 and P7) and Lake Centre (P8). A suite of biomarkers in caged fish after in situ exposure for 28 days, coupled with six selected exogenous estrogens in water, were determined in May and December 2011. Six target estrogens, namely estrone (E1), 17b-estradiol (E2), ethinylestradiol (EE2), estriol (E3), diethylstilbestrol (DES) and bisphenol A (BPA), were quantified using UPLC/MS/MS. The concentrations of E1, E2, E3, EE2, DES and BPA ranged from ND to 3.61 ng/L, ND to 17.3 ng/L, ND to 1.65 ng/L, ND to 10.2 ng/L, ND to 34.6 ng/L, and 3.95 to 207 ng/L, respectively. BPA was detected at all sampling points at all test periods, E2 was detected at 95% of samples, E1 and EE2 was detected at 75% of samples, and E3 was detected only in December 2011 with quite low concentrations. Each individual estrogen concentration measured at each sampling point was multiplied by its relative potency to gain the estradiol equivalent (EEQ). The total EEQ values in all the monitoring points ranged from 5.69 to 17.8 ng/L in May 2011, and from 4.46 to 21.1 ng/L in December 2011. E2 and EE2 were thought to be the major causal agents responsible for the estrogenic activities. Serum vitellogenin and E2 levels, gonadal DNA damage, and gonadosomatic index were measured in the in situ exposed fish. An enhanced integrated biomarker response (EIBR) was calculated and used to evaluate potential feminization risk of fish in the polluted area of Taihu Lake. EIBR index showed good agreement with the observed total EEQ levels in water. Our results indicated that Gong bay and the lake center had a low estrogenic risk, whereas Wangyuhe River, Meiliang Bay, and Zhushan Bay might present a higher risk to fish.

Keywords: active biomonitoring, estrogen, feminization risk, Taihu Lake

Procedia PDF Downloads 274
9131 Balanced Ischemia Misleading to a False Negative Myocardial Perfusion Imaging (Stress) Test

Authors: Devam Sheth

Abstract:

Nuclear imaging with stress myocardial perfusion (stress test) is the preferred first line investigation for noninvasive evaluation of ischaemic heart condition. The sensitivity of this test is close to 90 % making it a very reliable test. However, rarely it gives a false negative result which can be explained by the phenomenon termed as “balanced ischaemia”. We present the case of a 78 year Caucasian female without any significant past cardiac history, who presents with chest pain and shortness of breath since one day. The initial ECG and cardiac enzymes were non-impressive. Few hours later, she had some substernal chest pain along with some ST segment depression in the lateral leads. Stress test comes back negative for any significant perfusion defects. However, given her typical symptoms, she underwent a cardiac catheterization which revealed significant triple vessel disease mandating her to get a bypass surgery. This unusual phenomenon of false nuclear stress test in the setting of positive ECG changes can be explained only by balanced ischemia wherein due to global myocardial ischemia, the stress test fails to reveal relative perfusion defects in the affected segments.

Keywords: balanced, false positive, ischemia, myocardial perfusion imaging

Procedia PDF Downloads 297
9130 Comparing Student Performance on Paper-Based versus Computer-Based Formats of Standardized Tests

Authors: Jin Koo

Abstract:

During the coronavirus pandemic, there has been a further increasing demand for computer-based tests (CBT), and now it has become an important test mode. The main purpose of this study is to investigate the comparability of student scores obtained from computerized-based formats of a standardized test in the two subject areas of reading and mathematics. Also, this study investigates whether there is an interaction effect between test modes of CBT and paper-based tests (PBT) and gender/ability level in each subject area. The test used in this study is a multiple-choice standardized test for students in grades 8-11. For this study, data were collected during four test administrations: 2015-16, 2017-18, and 2020-21. This research used a one-factor between-subjects ANOVA to compute the PBT and CBT groups’ test means for each subject area (reading and mathematics). Also, 2-factor between-subjects ANOVAs were conducted to investigate examinee characteristics: gender (male and female), ethnicity (African-American, Asian, Hispanic, multi-racial, and White), and ability level (low, average, and high-ability groups). The author found that students’ test scores in the two subject areas varied across CBT and PBT by gender and ability level, meaning that gender, ethnicity, and ability level were related to the score difference. These results will be discussed according to the current testing systems. In addition, this study’s results will open up to school teachers and test developers the possible influence that gender, ethnicity, and ability level have on a student’s score based on whether they take the CBT or PBT.

Keywords: ability level, computer-based, gender, paper-based, test

Procedia PDF Downloads 97
9129 Audit Examining Maternity Assessment Suite Triage Compliance with Birmingham Symptom Specific Obstetric Triage System in a London Teaching Hospital

Authors: Sarah Atalla, Shubham Gupta, Kim Alipio, Tanya Maric

Abstract:

Background: Chelsea and Westminster Hospital have introduced the Birmingham Symptom Specific Obstetric Triage System (BSOTS) for patients who present acutely to the Maternity Assessment Suite (MAS) to prioritise care by urgency. The primary objective was to evaluate whether BSOTS was used appropriately to assess patients (defined as a 90% threshold). The secondary objective was to assess whether patients were seen within their designated triaged timeframe (defined as a 90% threshold). Methodology: MAS records were retrospectively reviewed for a randomly selected one-week period of data from 2020 (21/09/2020 - 27/09/2020). 189 patients presented to MAS during this time. Data were collected on the presenting complaint, time of attendance (divided into four time categories), and triage colour code for the urgency of a review by a doctor (red: immediately, orange: within 15 minutes, yellow: within 1 hour, green: within 4 hours). The number of triage waiting times that were breached and the outcome of the attendance was noted. Results: 49% of patients presenting to MAS during this time period were triaged, which therefore did not meet the 90% target. 67% of patients who were triaged were seen within their allocated timeframe as designated by their triage colour code, which therefore did not meet the 90% target. The most frequent reason for patient attendance was reduced fetal movements (30.5% of attendances). The busiest time of day (when most patients presented) was between 06:01-12:00, and this was also when the highest number of patients were not triaged (26 patients or 54% of patients presenting in this time category). The most used triage category (59%) was the green colour code (to be seen by a doctor within 4 hours), followed by orange (24%), yellow (14%), and red (3%). 45% of triaged patients were admitted, whilst 55% were discharged. 62% of patients allocated to the green triage category were discharged, as compared to 56% of yellow category patients, 27% of orange category patients, and 50% of red category patients. The time of patient presentation to the hospital was also associated with the level of urgency and outcome. Patients presenting from 12:01 to 18:00 were more likely to be discharged (72% discharged) compared to 00:01-06:00 where only 12.5% of patients were discharged. Conclusion: The triage system for assessing the urgency of acutely presenting obstetric patients is only being effectively utilised for 49% of patients. There is potential for enhancing the employment of the triage system to enable further efficiency and boost the promotion of patient safety. It is noted that MAS was busiest at 06:01 - 12:00 when there was also the highest number of non-triaged patients – this highlights some areas where we can improve, including higher levels of staffing, better use of BSOTS to triage patients, and patient education.

Keywords: birmingham, BSOTS, maternal, obstetric, pregnancy, specific, symptom, triage

Procedia PDF Downloads 99
9128 Manual Dexterity in Patients with Motor Neuron Disease

Authors: Magdalena Barbara Kaziuk, Ilona Hubner, Jacek Hubner, Slawomir Kroczka

Abstract:

Background: The motor neuron disease is a progressive neurodegenerative disease causing malfunction. Irrespective of the form of the disease and its onset always leads to the worsening of the quality of life, with patients usually depending on the family. Materials and methods: The study included 20 persons (5 females, 15 males, aged 65,5 ± 20 years) with clinically certain or probable diagnosis of the motor neuron disease. Patients were examined three times in the period of six months. The diagnosis was established based on the criteria of El Escorial. Manual dexterity was assessed using the test of the card Rene Zazzo and the test of shading in with lines Mira Stambak. Results: All patients achieved unsatisfactory results in Rene Zazzo’s test of the card and most of the patients (60%) in Mira Stambak’s test of shading with lines. Significantly higher test results were achieved for Rene Zazzo’s test and lower test results for Mira Stambak’s test in consecutive measurements. Conclusions: Impairment of manual dexterity is present already at the moment of diagnosing the disease and is growing significantly during its course. The quality of life for MND patients undergoes gradual deterioration as a result of the malfunction.

Keywords: manual dexterity, motor neuron disease, quality of life, malfunction

Procedia PDF Downloads 334
9127 Practical Methods for Automatic MC/DC Test Cases Generation of Boolean Expressions

Authors: Sekou Kangoye, Alexis Todoskoff, Mihaela Barreau

Abstract:

Modified Condition/Decision Coverage (MC/DC) is a structural coverage criterion that aims to prove that all conditions involved in a Boolean expression can influence the result of that expression. In the context of automotive, MC/DC is highly recommended and even required for most security and safety applications testing. However, due to complex Boolean expressions that often embedded in those applications, generating a set of MC/DC compliant test cases for any of these expressions is a nontrivial task and can be time consuming for testers. In this paper we present an approach to automatically generate MC/DC test cases for any Boolean expression. We introduce novel techniques, essentially based on binary trees to quickly and optimally generate MC/DC test cases for the expressions. Thus, the approach can be used to reduce the manual testing effort of testers.

Keywords: binary trees, MC/DC, test case generation, nontrivial task

Procedia PDF Downloads 439
9126 A Study on the Method of Accelerated Life Test to Electric Rotating System

Authors: Youn-Hwan Kim, Jae-Won Moon, Hae-Joong Kim

Abstract:

This paper introduces the study on the method of accelerated life test to electrical rotating system. In recent years, as well as efficiency for motors and generators, there is a growing need for research on the life expectancy. It is considered impossible to calculate the acceleration coefficient by increasing the rotational load or temperature load as the acceleration stress in the motor system because the temperature of the copper exceeds the wire thermal class rating. In this paper, the accelerated life test methods of the electrical rotating system are classified according to the application. This paper describes the development of the test procedure for the highly accelerated life test (HALT) of the 100kW permanent magnet synchronous motor (PMSM) of electric vehicle. Finally, it explains how to select acceleration load for vibration, temperature, bearing load, etc. for accelerated life test.

Keywords: acceleration coefficient, electric vehicle motor, HALT, life expectancy, vibration

Procedia PDF Downloads 322
9125 On the Derivation of Variable Step BBDF for Solving Second Order Stiff ODEs

Authors: S. A. M. Yatim, Z. B. Ibrahim, K. I. Othman, M. Suleiman

Abstract:

The method of solving second order stiff ordinary differential equation (ODEs) that is based on backward differentiation formula (BDF) is considered in this paper. We derived the method by increasing the order of the existing method using an improved strategy in choosing the step size. Numerical results are presented to compare the efficiency of the proposed method to the MATLAB’s suite of ODEs solvers namely ode15s and ode23s. The method was found to be efficient to solve second order ordinary differential equation.

Keywords: backward differentiation formulae, block backward differentiation formulae, stiff ordinary differential equation, variable step size

Procedia PDF Downloads 490
9124 A Brief Study about Nonparametric Adherence Tests

Authors: Vinicius R. Domingues, Luan C. S. M. Ozelim

Abstract:

The statistical study has become indispensable for various fields of knowledge. Not any different, in Geotechnics the study of probabilistic and statistical methods has gained power considering its use in characterizing the uncertainties inherent in soil properties. One of the situations where engineers are constantly faced is the definition of a probability distribution that represents significantly the sampled data. To be able to discard bad distributions, goodness-of-fit tests are necessary. In this paper, three non-parametric goodness-of-fit tests are applied to a data set computationally generated to test the goodness-of-fit of them to a series of known distributions. It is shown that the use of normal distribution does not always provide satisfactory results regarding physical and behavioral representation of the modeled parameters.

Keywords: Kolmogorov-Smirnov test, Anderson-Darling test, Cramer-Von-Mises test, nonparametric adherence tests

Procedia PDF Downloads 440
9123 Scalable UI Test Automation for Large-scale Web Applications

Authors: Kuniaki Kudo, Raviraj Solanki, Kaushal Patel, Yash Virani

Abstract:

This research mainly concerns optimizing UI test automation for large-scale web applications. The test target application is the HHAexchange homecare management WEB application that seamlessly connects providers, state Medicaid programs, managed care organizations (MCOs), and caregivers through one platform with large-scale functionalities. This study focuses on user interface automation testing for the WEB application. The quality assurance team must execute many manual users interface test cases in the development process to confirm no regression bugs. The team automated 346 test cases; the UI automation test execution time was over 17 hours. The business requirement was reducing the execution time to release high-quality products quickly, and the quality assurance automation team modernized the test automation framework to optimize the execution time. The base of the WEB UI automation test environment is Selenium, and the test code is written in Python. Adopting a compilation language to write test code leads to an inefficient flow when introducing scalability into a traditional test automation environment. In order to efficiently introduce scalability into Test Automation, a scripting language was adopted. The scalability implementation is mainly implemented with AWS's serverless technology, an elastic container service. The definition of scalability here is the ability to automatically set up computers to test automation and increase or decrease the number of computers running those tests. This means the scalable mechanism can help test cases run parallelly. Then test execution time is dramatically decreased. Also, introducing scalable test automation is for more than just reducing test execution time. There is a possibility that some challenging bugs are detected by introducing scalable test automation, such as race conditions, Etc. since test cases can be executed at same timing. If API and Unit tests are implemented, the test strategies can be adopted more efficiently for this scalability testing. However, in WEB applications, as a practical matter, API and Unit testing cannot cover 100% functional testing since they do not reach front-end codes. This study applied a scalable UI automation testing strategy to the large-scale homecare management system. It confirmed the optimization of the test case execution time and the detection of a challenging bug. This study first describes the detailed architecture of the scalable test automation environment, then describes the actual performance reduction time and an example of challenging issue detection.

Keywords: aws, elastic container service, scalability, serverless, ui automation test

Procedia PDF Downloads 98
9122 Assessment of Association Between Microalbuminuria and Lung Function Test Among the Community of Jimma Town

Authors: Diriba Dereje

Abstract:

Background: Cardiac and renal disease are the most prevalent chronic non-communicable diseases (CNCD) affecting the community in a significant manner. The best and recommended method in halting CNCD is by working on prevention as early as possible. This is only possible if early surrogate markers are identified. As part of the stated solution, this study will identify an association between microalbuminuria (an early surrogate marker of renal and cardiac disease) and lung function test among adult in the community. Objective: The main aim of this study was to assess an association between microalbuminuria (an early surrogate marker of renal and cardiac disease) and lung function test among adult in the community. Methodology: Community based cross sectional study was conducted among 384 adult in Jimma town. A systematic sampling technique was used in selecting participants to the study. In searching for the possible association, binary and multivariate logistic regression and t-test was conducted. Finally, the association between microalbuminuria and lung function test was well stated in the form of figures and written description. Result and Conclusion: A significant association was found between microalbuminuria and different lung function test parameters.

Keywords: microalbuminuria, lung function, association, test

Procedia PDF Downloads 187
9121 A Study of the Weld Properties of Inconel 625 Based on Nb Content

Authors: JongWon Han, NoHoon Kim, HyoIk Ahn, HaeWoo Lee

Abstract:

In this study, shielded metal arc welding was performed as a function of Nb content at 2.24 wt%, 3.25 wt%, and 4.26 wt%. The microstructure was observed using scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) and showed the development of a columnar dendrite structure in the specimen having the least Nb content. From the hardness test, the hardness value was confirmed to reduce with decreasing Nb content. From electron backscatter diffraction (EBSD) analysis, the largest grain size was found in the specimen with Nb content of 2.24 wt%. The potentiodynamic polarization test was carried out to determine the pitting corrosion resistance; there was no significant difference in the pitting corrosion resistance with increasing Nb content. To evaluate the degree of sensitization to intergranular corrosion, the Double Loop Electrochemical Potentiodynamic Reactivation(DL-EPR test) was conducted. A similar degree of sensitization was found in two specimens except with a Nb content of 2.24 wt%, while a relatively high degree of sensitization was found in the specimen with a Nb content of 2.24 wt%.

Keywords: inconel 625, Nb content, potentiodynamic test, DL-EPR test

Procedia PDF Downloads 300
9120 Developing a Staff Education Program on Subglottic Suction Endotracheal Tubes

Authors: Emily Toon

Abstract:

Nurses play a critical role in the prevention of ventilator-associated pneumonia through the maintenance of endotracheal tubes and use of subglottic secretion drainage via subglottic suctioning endotracheal tubes. The purpose of this evidence based practice project is to develop a staff education program on subglottic suctioning endotracheal tubes for critical care nurses at Middlesex Health with the aim of determining and documenting increased knowledge and/or practice change. The setting included registered nurses within Middlesex Health’s critical care unit who were recruited to complete a pre-test (n=14), view a presentation, and complete a post-test (n=10). Average pre-test scores were compared to average post-test scores to determine an increase in knowledge and/or practice change. The overall mean pre-test score was 59.7 percent, compared with the mean post-test score of 88.1 percent. Pre- and post-test scores were unmatched, so statistical significance could not be determined. The hypothesis that a staff education program on subglottic suctioning endotracheal tubes would demonstrate an increase in knowledge was supported, but not statistically. By integrating a pre-test/post-test design into educational presentations to evaluate increased knowledge, data generated may be used to improve methods and practices of delivering education and enhance staff learning.

Keywords: endotracheal tubes, staff education, subglottic secretion drainage, ventilator-associated pneumonia

Procedia PDF Downloads 108
9119 An Integrated Tailoring Method for Thermal Cycling Tests of Spacecraft Electronics

Authors: Xin-Yan Ji, Jing Wang, Chang Liu, Yan-Qiang Bi, Zhong-Xu Xu, Xi-Yuan Li

Abstract:

Thermal tests of electronic units are critically important for the reliability validation and performance demonstration of the spacecraft hard-wares. The tailoring equation in MIL-STD-1540 is based on fatigue of solder date. In the present paper, a new test condition tailoring expression is proposed to fit different thermo-mechanical fatigue and different subsystems, by introducing an integrated evaluating method for the fatigue acceleration exponent. The validate test has been accomplished and the data has been analyzed and compared with that from the MIL-STD-1540 tailoring equations. The results are encouraging and reasonable.

Keywords: thermal cycling test, thermal fatigue, tailoring equation, test condition planning

Procedia PDF Downloads 450
9118 Analysis of Bank Characteristics in a Hydrogen Refueling Station

Authors: Bo Hyun Kim, Sarng Woo Karng

Abstract:

In constructing a hydrogen refueling station, minimizing the volume and reducing the number of banks enable lessening the construction cost. This study aims at performing the dynamic simulation on 250 kg/day of a refueling station for light-duty vehicles. The primary compressor boosts hydrogen from a tube trailer of 250 to 480 bar and stores it in a medium-pressure bank. Then, additional compression of hydrogen from 480 to 900 bar is carried out and stored in a high-pressure bank. Economic analysis was conducted considering the amount of electricity consumed by compression corresponding to the volume and the number of banks (cascade system) in charging mode. NIST REFPROP was selected as the equation of state on the ASPEN HYSYS for thermodynamic analysis of the tube-trailer, the compressors, the chillers, and the banks. Compared to a single high-pressure bank system of 3000 L, the volume of the cascade high-pressure banks (bank1: 250 L and bank 2: 1850 L) was reduced by 30%, and the power consumption of the chiller for precooling was also decreased by 16%.

Keywords: light-duty vehicles, economic analysis, cascade system, hydrogen refueling station

Procedia PDF Downloads 85
9117 Trends in Language Testing in Primary Schools in River State, Nigeria

Authors: Okoh Chinasa, Asimuonye Augusta

Abstract:

This study investigated the trends in language testing in Primary Schools in Rivers State. English language past question papers were collected from four (4) Primary Schools in Onelga Local Government Area and Ahoada East Local Government Area. Four research questions guided the study. The study is aimed at finding out the appropriateness of test formats used for language testing and the language skills tested. The past question papers collected which served as the instrument were analyzed based on given criteria developed by the researchers in line with documentary frequency studies, a type of survey study. The study revealed that some of the four language skills were not adequately assessed and that the termly question papers were developed by a central examination body. From the past questions, it was observed that an imbalance exists in the test format used. The paper recommended that all the language skills should be tested using correct test formats to ensure that pupils were given a fair chance to show what they know and can do in English language and for teachers to be able to use the test results for effective decision making.

Keywords: discrete test, integrative test, testing approach, test format

Procedia PDF Downloads 416
9116 Effect of Self-Questioning Strategy on the Improvement of Reading Comprehension of ESL Learners

Authors: Muhammad Hamza

Abstract:

This research is based on the effect of self-questioning strategy on reading comprehension of second language learners at medium level. This research is conducted to find out the effects of self-questioning strategy and how self-questioning strategy helps English learners to improve their reading comprehension. In this research study the researcher has analyzed that how much self-questioning is effective in the field of learning second language and how much it helps second language learners to improve their reading comprehension. For this purpose, the researcher has studied different reading strategies, analyzed, collected data from certificate level class at NUML, Peshawar campus and then found out the effects of self-questioning strategy on reading comprehension of ESL learners. The researcher has randomly selected the participants from certificate class. The data was analyzed through pre-test and post-test and then in the final stage the results of both tests were compared. After the pre-test and post-test, the result of both pre-test and post-test indicated that if the learners start to use self-questioning strategy before reading a text, while reading a text and after reading a particular text there’ll be improvement in comprehension level of ESL learners. The present research has addressed the benefits of self-questioning strategy by taking two tests (pre and post-test).After the result of post-test it is revealed that the use of the self-questioning strategy has a significant effect on the readers’ comprehension thus, they can improve their reading comprehension by using self-questioning strategy.

Keywords: strategy, self-questioning, comprehension, intermediate level ESL learner

Procedia PDF Downloads 60
9115 Design of a Tool for Generating Test Cases from BPMN

Authors: Prat Yotyawilai, Taratip Suwannasart

Abstract:

Business Process Model and Notation (BPMN) is more important in the business process and creating functional models, and is a standard for OMG, which becomes popular in various organizations and in education. Researches related to software testing based on models are prominent. Although most researches use the UML model in software testing, not many researches use the BPMN Model in creating test cases. Therefore, this research proposes a design of a tool for generating test cases from the BPMN. The model is analyzed and the details of the various components are extracted before creating a flow graph. Both details of components and the flow graph are used in generating test cases.

Keywords: software testing, test case, BPMN, flow graph

Procedia PDF Downloads 552
9114 Mutagenic in vitro Activity and Genotoxic Effect of Zygophyllum Cornutun Methanolic Extract

Authors: Awatif Boumaza, Abderraouf Hilali, Hayat Talbi, Houda Sbayou

Abstract:

The methanolic extract of Zygophyllum cornutun coss, an Algerian medicinal plant, was screened to the presence of mutagenic activity and genotoxic effect using the Ames test (Salmonella/microsome) and the micronucleus assay respectively. Positive results were obtained with both tests. The Ames test showed mutagenic activity in the presence of microsomal activation, while negative result was observed without microsomal activation. In the micronucleus test, two parameters were evaluated: the frequency of the micronucleus that increased in a dose dependent way and the proliferation index that decreased according to the micronucleus frequency. Even that further studies must be carried out, the mutagenic activity and the genotoxic effect of Zygophyllum cornutum should be taken in consideration when used as therapeutic plant.

Keywords: ames test, micronucleus test, mutagenic activity, genotoxicity, Zygophyllum cornutum

Procedia PDF Downloads 506
9113 Settlement Analysis of Axially Loaded Bored Piles: A Case History

Authors: M. Mert, M. T. Ozkan

Abstract:

Pile load tests should be applied to check the bearing capacity calculations and to determine the settlement of the pile corresponding to test load. Strain gauges can be installed into pile in order to determine the shaft resistance of the piles for every soil layer respectively. Detailed results can be obtained by means of strain gauges placed at certain levels into test piles. In the scope of this study, pile load test data obtained from two different projects are examined.  Instrumented static pile load tests were applied on totally 7 test bored piles of different diameters (80 cm, 150 cm, and 200 cm) and different lengths (between 30-76 m) in two different project site. Settlement analysis of test piles is done by using some of load transfer methods and finite element method. Plaxis 3D which is a three-dimensional finite element program is also used for settlement analysis of the test piles. In this study, firstly bearing capacity of test piles are determined and compared with strain gauge data which is required for settlement analysis. Then, settlement values of the test piles are estimated by using load transfer methods developed in recent years and finite element method. The aim of this study is to show similarities and differences between the results obtained from settlement analysis methods and instrumented pile load tests.

Keywords: failure, finite element method, monitoring and instrumentation, pile, settlement

Procedia PDF Downloads 163
9112 Design of a Laboratory Test for InvestigatingPermanent Deformation of Asphalt

Authors: Esmaeil Ahmadinia, Frank Bullen, Ron Ayers

Abstract:

Many concerns have been raised in recent years about the adequacy of existing creep test methods for evaluating rut-resistance of asphalt mixes. Many researchers believe the main reason for the creep tests being unable to duplicate field results is related to a lack of a realistic confinement for laboratory specimens. In-situ asphalt under axle loads is surrounded by a mass of asphalt, which provides stress-strain generated confinement. However, most existing creep tests are largely unconfined in their nature. It has been hypothesised that by providing a degree of confinement, representative of field conditions, in a creep test, it could be possible to establish a better correlation between the field and laboratory. In this study, a new methodology is explored where confinement for asphalt specimens is provided. The proposed methodology is founded on the current Australian test method, adapted to provide simulated field conditions through the provision of sample confinement.

Keywords: asphalt mixture, creep test, confinements, permanent deformation

Procedia PDF Downloads 315
9111 Density Measurement of Mixed Refrigerants R32+R1234yf and R125+R290 from 0°C to 100°C and at Pressures up to 10 MPa

Authors: Xiaoci Li, Yonghua Huang, Hui Lin

Abstract:

Optimization of the concentration of components in mixed refrigerants leads to potential improvement of either thermodynamic cycle performance or safety performance of heat pumps and refrigerators. R32+R1234yf and R125+R290 are two promising binary mixed refrigerants for the application of heat pumps working in the cold areas. The p-ρ-T data of these mixtures are one of the fundamental and necessary properties for design and evaluation of the performance of the heat pumps. Although the property data of mixtures can be predicted by the mixing models based on the pure substances incorporated in programs such as the NIST database Refprop, direct property measurement will still be helpful to reveal the true state behaviors and verify the models. Densities of the mixtures of R32+R1234yf an d R125+R290 are measured by an Anton Paar U shape oscillating tube digital densimeter DMA-4500 in the range of temperatures from 0°C to 100 °C and pressures up to 10 MPa. The accuracy of the measurement reaches 0.00005 g/cm³. The experimental data are compared with the predictions by Refprop in the corresponding range of pressure and temperature.

Keywords: mixed refrigerant, density measurement, densimeter, thermodynamic property

Procedia PDF Downloads 290
9110 Multi-Label Approach to Facilitate Test Automation Based on Historical Data

Authors: Warda Khan, Remo Lachmann, Adarsh S. Garakahally

Abstract:

The increasing complexity of software and its applicability in a wide range of industries, e.g., automotive, call for enhanced quality assurance techniques. Test automation is one option to tackle the prevailing challenges by supporting test engineers with fast, parallel, and repetitive test executions. A high degree of test automation allows for a shift from mundane (manual) testing tasks to a more analytical assessment of the software under test. However, a high initial investment of test resources is required to establish test automation, which is, in most cases, a limitation to the time constraints provided for quality assurance of complex software systems. Hence, a computer-aided creation of automated test cases is crucial to increase the benefit of test automation. This paper proposes the application of machine learning for the generation of automated test cases. It is based on supervised learning to analyze test specifications and existing test implementations. The analysis facilitates the identification of patterns between test steps and their implementation with test automation components. For the test case generation, this approach exploits historical data of test automation projects. The identified patterns are the foundation to predict the implementation of unknown test case specifications. Based on this support, a test engineer solely has to review and parameterize the test automation components instead of writing them manually, resulting in a significant time reduction for establishing test automation. Compared to other generation approaches, this ML-based solution can handle different writing styles, authors, application domains, and even languages. Furthermore, test automation tools require expert knowledge by means of programming skills, whereas this approach only requires historical data to generate test cases. The proposed solution is evaluated using various multi-label evaluation criteria (EC) and two small-sized real-world systems. The most prominent EC is ‘Subset Accuracy’. The promising results show an accuracy of at least 86% for test cases, where a 1:1 relationship (Multi-Class) between test step specification and test automation component exists. For complex multi-label problems, i.e., one test step can be implemented by several components, the prediction accuracy is still at 60%. It is better than the current state-of-the-art results. It is expected the prediction quality to increase for larger systems with respective historical data. Consequently, this technique facilitates the time reduction for establishing test automation and is thereby independent of the application domain and project. As a work in progress, the next steps are to investigate incremental and active learning as additions to increase the usability of this approach, e.g., in case labelled historical data is scarce.

Keywords: machine learning, multi-class, multi-label, supervised learning, test automation

Procedia PDF Downloads 128