Search results for: Aviation Synthetic Efficiency Test
14710 Liquefaction Assessment of Marine Soil in Western Yemen Region Based on Laboratory and Field Tests
Authors: Monalisha Nayak, T. G. Sitharam
Abstract:
Liquefaction is a major threat for sites consists of or on sandy soil. But this present study concentrates on the behavior of fine soil under cyclic loading. This paper presents the study of liquefaction susceptibility of marine silty clay to clayey silt for an offshore site near western Yemen. The submerged and loose sediment condition of marine soil of an offshore site can favour liquefaction during earthquakes. In this regard, the liquefaction susceptibility of the site was carried out based on both field test results and laboratory test results. From field test results of seismic cone penetration test (SCPT), liquefaction susceptibility was assessed considering normalized cone tip resistance, and normalized friction ratio and results give an idea regarding both cyclic mobility and flow liquefaction. Laboratory cyclic triaxial tests were also conducted on saturated undisturbed and remoulded sample to study the effect of cyclic loading on strength and strain characteristics. Liquefaction susceptibility of the marine soft soil was also carried out based on index properties like grain size distribution, natural moisture content and liquid limit of soil.Keywords: index properties, liquefaction, marine soil, seismic cone penetration test (SCPT)
Procedia PDF Downloads 23214709 Energy Efficient Plant Design Approaches: Case Study of the Sample Building of the Energy Efficiency Training Facilities
Authors: Idil Kanter Otcu
Abstract:
Nowadays, due to the growing problems of energy supply and the drastic reduction of natural non-renewable resources, the development of new applications in the energy sector and steps towards greater efficiency in energy consumption are required. Since buildings account for a large share of energy consumption, increasing the structural density of buildings causes an increase in energy consumption. This increase in energy consumption means that energy efficiency approaches to building design and the integration of new systems using emerging technologies become necessary in order to curb this consumption. As new systems for productive usage of generated energy are developed, buildings that require less energy to operate, with rational use of resources, need to be developed. One solution for reducing the energy requirements of buildings is through landscape planning, design and application. Requirements such as heating, cooling and lighting can be met with lower energy consumption through planting design, which can help to achieve more efficient and rational use of resources. Within this context, rather than a planting design which considers only the ecological and aesthetic features of plants, these considerations should also extend to spatial organization whereby the relationship between the site and open spaces in the context of climatic elements and planting designs are taken into account. In this way, the planting design can serve an additional purpose. In this study, a landscape design which takes into consideration location, local climate morphology and solar angle will be illustrated on a sample building project.Keywords: energy efficiency, landscape design, plant design, xeriscape landscape
Procedia PDF Downloads 26114708 Efficiency and Limits of Physicochemical Treatment of Dairy Wastewater: A Case Study of Dairy Industry in Western Algeria
Authors: Khedidja Benouis
Abstract:
Environmental issues in the food industry are related to the water because it consumes water and release large volumes of wastewater. The treatment of such discharges techniques can be adapted to different situations encountered. For dairy effluents, it is necessary and very effective to use a treatment that eliminates much of the pollutant load,thus, to drastically reduce the organic loading rate. This study aims to evaluate the Efficiency and limitations of physicochemical treatment by coagulation - flocculation of liquid effluent from this type of food industry in Algeria, to give an example of the type and the degree of pollution generated by this sector and in order to reduce pollution and minimize its environmental issues. Coagulation - flocculation-sedimentation was carried out using lime without addition of additive (flocculant), the processing efficiency is indicated by the concentration of pollutants in treated water. The results show that treatment is not sufficient to remove organic pollution, but it has significantly reduced the Total suspended solids (TSS), nitrate (NO3-N) and phosphate (PO4-P).Keywords: Algeria, coagulation-flocculation, dairy effluent, treatment
Procedia PDF Downloads 42214707 Effects of an Educational Program on Nurses Knowledge and Practice Related to Hepatitis-B: Pre-Experimental Design
Authors: R. S. Mehta, G. N. Mandal
Abstract:
Hepatitis-B is the major infectious disease of mankind. In Nepal it is reported that more than 4.3% of Nepalese population at any time in their life has been infected with Hepatitis-B virus (HBV). The objective of this study was to evaluate the effectiveness of planned educational programme regarding knowledge and practice of hepatitis-B among the nurses working at medical units of BPKIHS. Pre-experimental research design was used to conduct the study among the nurses working in medical units of BPKIHS. Total 40 nurses were included in the pre-test and 34 in the post-test. The education intervention was arranged on 24th May 2012 from 2:15 pm to 4:45 pm i.e. two and half hours. After two weeks of education intervention post-test was conducted. Most of the participants (60%) were of the age group of 18-22 years, Hindu (82.5%), and unmarried (65%). After education intervention there is significant differences in knowledge on the components of Hepatitis-B at 0.05 level of significance. There is no difference in the attitude components after post-test except the component patient contaminated with Hepatitis-B must be called as the last patient (p=0.035). It can conclude that hepatitis-B educational program improved knowledge and practice among the nurses.Keywords: educational program, Hepatitis-B, pre-experimental design, medical units
Procedia PDF Downloads 35714706 Laboratory Evaluation of Rutting and Fatigue Damage Resistance of Asphalt Mixtures Modified with Carbon Nano Tubes
Authors: Ali Zain Ul Abadeen, Arshad Hussain
Abstract:
Roads are considered as the national capital, and huge developmental budget is spent on its construction, maintenance, and rehabilitation. Due to proliferating traffic volume, heavier loads and challenging environmental factors, the need for high-performance asphalt pavement is increased. In this research, the asphalt mixture was modified with carbon nanotubes ranging from 0.2% to 2% of binder to study the effect of CNT modification on rutting potential and fatigue life of asphalt mixtures. During this study, the conventional and modified asphalt mixture was subjected to a uni-axial dynamic creep test and dry Hamburg wheel tracking test to study rutting resistance. Fatigue behavior of asphalt mixture was studied using a four-point bending test apparatus. The plateau value of asphalt mixture was taken as a measure of fatigue performance according to the ratio of dissipated energy approach. Results of these experiments showed that CNT modified asphalt mixtures had reduced rut depth and increased rutting and fatigue resistance at higher percentages of carbon nanotubes.Keywords: carbon nanotubes, fatigue, four point bending test, modified asphalt, rutting
Procedia PDF Downloads 14514705 Study Concerning the Energy-to-Mass Ratio in Pneumatic Muscles
Authors: Tudor Deaconescu, Andrea Deaconescu
Abstract:
The utilization of pneumatic muscles in the actuation of industrial systems is still in its early stages, hence studies on the constructive solutions which include an assessment of their functional performance with a focus on one of the most important characteristics-energy efficiency are required. A quality indicator that adequately reflects the energy efficiency of an actuator is the energy-to-mass ratio. This ratio is computed in the paper for various types and sizes of pneumatic muscles manufactured by Festo, and is subsequently compared to the similar ratios determined for two categories of pneumatic cylinders.Keywords: pneumatic cylinders, pneumatic muscles, energy-to-mass ratio, muscle stroke
Procedia PDF Downloads 34614704 The Role and Effectiveness of Audit Committee in Corporate Governance of Credit Institutions
Authors: Tina Vuko, Marija Maretić, Marko Čular
Abstract:
The aim of this study is to analyze the role and effectiveness of internal mechanism (audit committee) of corporate governance on credit institutions performance in Croatia. Based on research objective, sample of 78 credit institutions listed on Zagreb Stock Exchange, from 2007 to 2012, has been collected and efficiency index of audit committee (EIAC) has been created. Based on the sample and created EIAC, conclusions are as follows: audit committees of credit institutions have medium efficiency, based on EIAC measurement; there is a significant difference in audit committee effectiveness, in observed period; there is no positive relationship between audit committee effectiveness and credit institution performance; there is a significant difference between level of audit committee effectiveness and audit firm type. Future research should contain increased number of elements in EIAC creation and increased sample, for all obligators who need to establish audit committee.Keywords: corporate governance, audit committee, financial institutions, efficiency index of audit committee
Procedia PDF Downloads 32114703 The Closed Cavity Façade (CCF): Optimization of CCF for Enhancing Energy Efficiency and Indoor Environmental Quality in Office Buildings
Authors: Michalis Michael, Mauro Overend
Abstract:
Buildings, in which we spend 87-90% of our time, act as a shelter protecting us from environmental conditions and weather phenomena. The building's overall performance is significantly dependent on the envelope’s glazing part, which is particularly critical as it is the most vulnerable part to heat gain and heat loss. However, conventional glazing technologies have relatively low-performance thermo-optical characteristics. In this regard, during winter, the heat losses due to the glazing part of a building envelope are significantly increased as well as the heat gains during the summer period. In this study, the contribution of an innovative glazing technology, namely Closed Cavity Façade (CCF) in improving energy efficiency and IEQ in office buildings is examined, aiming to optimize various design configurations of CCF. Using Energy Plus and IDA ICE packages, the performance of several CCF configurations and geometries for various climate types were investigated, aiming to identify the optimum solution. The model used for the simulations and optimization process was MATELab, a recently constructed outdoor test facility at the University of Cambridge (UK). The model was previously experimentally calibrated. The study revealed that the use of CCF technology instead of conventional double or triple glazing leads to important benefits. Particularly, the replacement of the traditional glazing units, used as the baseline, with the optimal configuration of CCF led to a decrease in energy consumption in the range of 18-37% (depending on the location). This mainly occurs due to integrating shading devices in the cavity and applying proper glass coatings and control strategies, which lead to improvement of thermal transmittance and g-value of the glazing. Since the solar gain through the façade is the main contributor to energy consumption during cooling periods, it was observed that a higher energy improvement is achieved in cooling-dominated locations. Furthermore, it was shown that a suitable selection of the constituents of a closed cavity façade, such as the colour and type of shading devices and the type of coatings, leads to an additional improvement of its thermal performance, avoiding overheating phenomena and consequently ensuring temperatures in the glass cavity below the critical value, and reducing the radiant discomfort providing extra benefits in terms of Indoor Environmental Quality (IEQ).Keywords: building energy efficiency, closed cavity façade, optimization, occupants comfort
Procedia PDF Downloads 6514702 The Test of Memory Malingering and Offence Severity
Authors: Kenji Gwee
Abstract:
In Singapore, the death penalty remains in active use for murder and drug trafficking of controlled drugs such as heroin. As such, the psychological assessment of defendants can often be of high stakes. The Test of Memory Malingering (TOMM) is employed by government psychologists to determine the degree of effort invested by defendants, which in turn inform on the veracity of overall psychological findings that can invariably determine the life and death of defendants. The purpose of this study was to find out if defendants facing the death penalty were more likely to invest less effort during psychological assessment (to fake bad in hopes of escaping the death sentence) compared to defendants facing lesser penalties. An archival search of all forensic cases assessed in 2012-2013 by Singapore’s designated forensic psychiatric facility yielded 186 defendants’ TOMM scores. Offence severity, coded into 6 rank-ordered categories, was analyzed in a one-way ANOVA with TOMM score as the dependent variable. There was a statistically significant difference (F(5,87) = 2.473, p = 0.038). A Tukey post-hoc test with Bonferroni correction revealed that defendants facing lower charges (Theft, shoplifting, criminal breach of trust) invested less test-taking effort (TOMM = 37.4±12.3, p = 0.033) compared to those facing the death penalty (TOMM = 46.2±8.1). The surprising finding that those facing death penalties actually invested more test taking effort than those facing relatively minor charges could be due to higher levels of cooperation when faced with death. Alternatively, other legal avenues to escape the death sentence may have been preferred over the mitigatory chance of a psychiatric defence.Keywords: capital sentencing, offence severity, Singapore, Test of Memory Malingering
Procedia PDF Downloads 43414701 Using the ISO 9705 Room Corner Test for Smoke Toxicity Quantification of Polyurethane
Authors: Gabrielle Peck, Ryan Hayes
Abstract:
Polyurethane (PU) foam is typically sold as acoustic foam that is often used as sound insulation in settings such as night clubs and bars. As a construction product, PU is tested by being glued to the walls and ceiling of the ISO 9705 room corner test room. However, when heat is applied to PU foam, it melts and burns as a pool fire due to it being a thermoplastic. The current test layout is unable to accurately measure mass loss and doesn’t allow for the material to burn as a pool fire without seeping out of the test room floor. The lack of mass loss measurement means gas yields pertaining to smoke toxicity analysis can’t be calculated, which makes data comparisons from any other material or test method difficult. Additionally, the heat release measurements are not representative of the actual measurements taken as a lot of the material seeps through the floor (when a tray to catch the melted material is not used). This research aimed to modify the ISO 9705 test to provide the ability to measure mass loss to allow for better calculation of gas yields and understanding of decomposition. It also aimed to accurately measure smoke toxicity in both the doorway and duct and enable dilution factors to be calculated. Finally, the study aimed to examine if doubling the fuel loading would force under-ventilated flaming. The test layout was modified to be a combination of the SBI (single burning item) test set up inside oof the ISO 9705 test room. Polyurethane was tested in two different ways with the aim of altering the ventilation condition of the tests. Test one was conducted using 1 x SBI test rig aiming for well-ventilated flaming. Test two was conducted using 2 x SBI rigs (facing each other inside the test room) (doubling the fuel loading) aiming for under-ventilated flaming. The two different configurations used were successful in achieving both well-ventilated flaming and under-ventilated flaming, shown by the measured equivalence ratios (measured using a phi meter designed and created for these experiments). The findings show that doubling the fuel loading will successfully force under-ventilated flaming conditions to be achieved. This method can therefore be used when trying to replicate post-flashover conditions in future ISO 9705 room corner tests. The radiative heat generated by the two SBI rigs facing each other facilitated a much higher overall heat release resulting in a more severe fire. The method successfully allowed for accurate measurement of smoke toxicity produced from the PU foam in terms of simple gases such as oxygen depletion, CO and CO2. Overall, the proposed test modifications improve the ability to measure the smoke toxicity of materials in different fire conditions on a large-scale.Keywords: flammability, ISO9705, large-scale testing, polyurethane, smoke toxicity
Procedia PDF Downloads 7614700 Synthesis of Montmorillonite/CuxCd1-xS Nanocomposites and Their Application to the Photodegradation of Methylene Blue
Authors: H. Boukhatem, L. Djouadi, H. Khalaf, R. M. Navarro, F. V. Ganzalez
Abstract:
Synthetic organic dyes are used in various industries, such as textile industry, leather tanning industry, paper production, hair dye production, etc. Wastewaters containing these dyes may be harmful to the environment and living organisms. Therefore, it is very important to remove or degrade these dyes before discharging them into the environment. In addition to standard technologies for the degradation and/or removal of dyes, several new specific technologies, the so-called advanced oxidation processes (AOPs), have been developed to eliminate dangerous compounds from polluted waters. AOPs are all characterized by the same chemical feature: production of radicals (•OH) through a multistep process, although different reaction systems are used. These radicals show little selectivity of attack and are able to oxidize various organic pollutants due to their high oxidative capacity (reduction potential of HO• Eo = 2.8 V). Heterogeneous photocatalysis, as one of the AOPs, could be effective in the oxidation/degradation of organic dyes. A major advantage of using heterogeneous photocatalysis for this purpose is the total mineralization of organic dyes, which results in CO2, H2O and corresponding mineral acids. In this study, nanomaterials based on montmorillonite and CuxCd1-xS with different Cu concentration (0.3 < x < 0.7) were utilized for the degradation of the commercial cationic textile dye Methylene blue (MB), used as a model pollutant. The synthesized nanomaterials were characterized by fourier transform infrared (FTIR) and thermogravimetric-differential thermal analysis (TG–DTA). Test results of photocatalysis of methylene blue under UV-Visible irradiation show that the photoactivity of nanomaterials montmorillonite/ CuxCd1-xS increases with the increasing of Cu concentration. The kinetics of the degradation of the MB dye was described with the Langmuir–Hinshelwood (L–H) kinetic model.Keywords: heterogeneous photocatalysis, methylene blue, montmorillonite, nanomaterial
Procedia PDF Downloads 37414699 Polyethylenimine-Ethoxylated Dual Interfacial Layers for High-Efficient Quantum Dot Light-Emitting Diodes
Authors: Woosuk Lee
Abstract:
We controlled the electron injection rate in inverted quantum dot light-emitting diode (QLED) by inserting PEIE layer between ZnO electron transport layer(ETL) and quantum dots(QDs) layer and successfully demonstrated high efficiency of QLEDs. The inverted QLED has the layer structure of ITO(cathode)/ ZnO NPs/PEIE/QDs/PEIE/P-TPD/MoO3/Al(anode). The PEIE between poly-TPD hole transport layer (HTL) and quantum dot emitting layer protects QD EML during HTL coating process and improves the surface morphology. In addition, the hole injection barrier is reduced by upshifting the valence band maximum (VBM) of QDs. An additional layer of PEIE was introduced between ZnO and QD to balance charge within QD emissive layer in device, which serves as an effective electron blocking layer without changing device operating condition such as turn-on voltage and emissive spectra. As a result, the optimized QLED with 5nm PEIE shows a ~36% improved current efficiency and external quantum efficiency (EQE) compared to the QLED without PEIE.(maximum current efficiency, and EQE are achieved 70cd/A and 17.3%, respectively). In particular, the maximum brightness of the optimized QLED dramatically improved by a factor of 2.3 relative to the QLED without PEIE. The main reasons for these QLED performance improvement are due to the suppressing the leakage current across the device and well confined exciton by inserting PEIE layers.Keywords: quantum dot light-emitting diodes, interfacial layer, charge-injection balance, suppressing QD charging
Procedia PDF Downloads 18314698 DC/DC Boost Converter Applied to Photovoltaic Pumping System Application
Authors: S. Abdourraziq, M. A. Abdourraziq
Abstract:
One of the most famous and important applications of solar energy systems is water pumping. It is often used for irrigation or to supply water in countryside or private firm. However, the cost and the efficiency are still a concern, especially with a continued variation of solar radiation and temperature throughout the day. Then, the improvement of the efficiency of the system components is one of the different solutions to reducing the cost. In this paper, we will present a detailed definition of each element of a PV pumping system, and we will present the different MPPT algorithm used in the literature. Our system consists of a PV panel, a boost converter, a motor-pump set, and a storage tank.Keywords: PV cell, converter, MPPT, MPP, PV pumping system
Procedia PDF Downloads 15814697 Investigation of Antidepressant Activity of Dracaena Trifasciata in Rats
Authors: Samiah Rehman, Kashmira J. Gohil
Abstract:
Objective: Dracaena trifascaita extract (DTE) possesses strong antioxidant and anti-inflammatory properties that play a vital role in the treatment of mental disorders like depression. The present study was designed to evaluate the antidepressant effects of hydroalcoholic extracts of DT on behavioral models of depression. Methodology: Animals were randomly divided into 6 groups of 5 each: Group 1 and 2 received distilled water and standard drug, imipramine: 25mg/kg, respectively. Groups 4, 5 and 6 received DTE treatment orally at doses of 200 ,400 and 600mg/ kg, respectively, for 14 days. Time of immobility was noted by force swimming test (FST)and tail suspension test (TST) on the 1st,7th and 14th days. Results: The time of immobility was reduced in the treatment group as compared to the control and standard. DTE600 mg/kg showed the highest and most significant antidepressant effects as compared to the standard drug imipramine. (25mg/kg). Conclusion: DTE has good potential as an alternative therapy for depression.Keywords: Dracaena trifasciata, antidepressants, force swimming test, tail suspension test, herbal drug of depression
Procedia PDF Downloads 7414696 Adaptation of the Scenario Test for Greek-speaking People with Aphasia: Reliability and Validity Study
Authors: Marina Charalambous, Phivos Phylactou, Thekla Elriz, Loukia Psychogios, Jean-Marie Annoni
Abstract:
Background: Evidence-based practices for the evaluation and treatment of people with aphasia (PWA) in Greek are mainly impairment-based. Functional and multimodal communication is usually under assessed and neglected by clinicians. This study explores the adaptation and psychometric testing of the Greek (GR) version of The Scenario Test. The Scenario Test assesses the everyday functional communication of PWA in an interactive multimodal communication setting with the support of an active communication facilitator. Aims: To define the reliability and validity of The Scenario Test GR and discuss its clinical value. Methods & Procedures: The Scenario Test-GR was administered to 54 people with chronic stroke (6+ months post-stroke): 32 PWA and 22 people with stroke without aphasia. Participants were recruited from Greece and Cyprus. All measures were performed in an interview format. Standard psychometric criteria were applied to evaluate reliability (internal consistency, test-retest, and interrater reliability) and validity (construct and known – groups validity) of the Scenario Test GR. Video analysis was performed for the qualitative examination of the communication modes used. Outcomes & Results: The Scenario Test-GR shows high levels of reliability and validity. High scores of internal consistency (Cronbach’s α = .95), test-retest reliability (ICC = .99), and interrater reliability (ICC = .99) were found. Interrater agreement in scores on individual items fell between good and excellent levels of agreement. Correlations with a tool measuring language function in aphasia (the Aphasia Severity Rating Scale of the Boston Diagnostic Aphasia Examination), a measure of functional communication (the Communicative Effectiveness Index), and two instruments examining the psychosocial impact of aphasia (the Stroke and Aphasia Quality of Life questionnaire and the Aphasia Impact Questionnaire) revealed good convergent validity (all ps< .05). Results showed good known – groups validity (Mann-Whitney U = 96.5, p < .001), with significantly higher scores for participants without aphasia compared to those with aphasia. Conclusions: The psychometric qualities of The Scenario Test-GR support the reliability and validity of the tool for the assessment of functional communication for Greek-speaking PWA. The Scenario Test-GR can be used to assess multimodal functional communication, orient aphasia rehabilitation goal setting towards the activity and participation level, and be used as an outcome measure of everyday communication. Future studies will focus on the measurement of sensitivity to change in PWA with severe non-fluent aphasia.Keywords: the scenario test GR, functional communication assessment, people with aphasia (PWA), tool validation
Procedia PDF Downloads 12814695 Seismic Vulnerability Analysis of Arch Dam Based on Response Surface Method
Authors: Serges Mendomo Meye, Li Guowei, Shen Zhenzhong
Abstract:
Earthquake is one of the main loads threatening dam safety. Once the dam is damaged, it will bring huge losses of life and property to the country and people. Therefore, it is very important to research the seismic safety of the dam. Due to the complex foundation conditions, high fortification intensity, and high scientific and technological content, it is necessary to adopt reasonable methods to evaluate the seismic safety performance of concrete arch dams built and under construction in strong earthquake areas. Structural seismic vulnerability analysis can predict the probability of structural failure at all levels under different intensity earthquakes, which can provide a scientific basis for reasonable seismic safety evaluation and decision-making. In this paper, the response surface method (RSM) is applied to the seismic vulnerability analysis of arch dams, which improves the efficiency of vulnerability analysis. Based on the central composite test design method, the material-seismic intensity samples are established. The response surface model (RSM) with arch crown displacement as performance index is obtained by finite element (FE) calculation of the samples, and then the accuracy of the response surface model (RSM) is verified. To obtain the seismic vulnerability curves, the seismic intensity measure ??(?1) is chosen to be 0.1~1.2g, with an interval of 0.1g and a total of 12 intensity levels. For each seismic intensity level, the arch crown displacement corresponding to 100 sets of different material samples can be calculated by algebraic operation of the response surface model (RSM), which avoids 1200 times of nonlinear dynamic calculation of arch dam; thus, the efficiency of vulnerability analysis is improved greatly.Keywords: high concrete arch dam, performance index, response surface method, seismic vulnerability analysis, vector-valued intensity measure
Procedia PDF Downloads 24014694 Pre-Treatment of Anodic Inoculum with Nitroethane to Improve Performance of a Microbial Fuel Cell
Authors: Rajesh P.P., Md. Tabish Noori, Makarand M. Ghangrekar
Abstract:
Methanogenic substrate loss is reported to be a major bottleneck in microbial fuel cell which significantly reduces the power production capacity and coulombic efficiency (CE) of microbial fuel cell (MFC). Nitroethane is found to be a potent inhibitor of hydrogenotrophic methanogens in rumen fermentation process. Influence of nitroethane pre-treated sewage sludge inoculum on suppressing the methanogenic activity and enhancing the electrogenesis in MFC was evaluated. MFC inoculated with nitroethane pre-treated anodic inoculum demonstrated a maximum operating voltage of 541 mV, with coulombic efficiency and sustainable volumetric power density of 39.85 % and 14.63 W/m3 respectively. Linear sweep voltammetry indicated a higher electron discharge on the anode surface due to enhancement of electrogenic activity while suppressing methanogenic activity. A 63 % reduction in specific methanogenic activity was observed in anaerobic sludge pre-treated with nitroethane; emphasizing significance of this pretreatment for suppressing methanogenesis and its utility for enhancing electricity generation in MFC.Keywords: coulombic efficiency, methanogenesis inhibition, microbial fuel cell, nitroethane
Procedia PDF Downloads 31814693 Autonomy Supportive Coaching to Achieve Health Literacy
Authors: E. Knisel, H. Rupprich, A. Heissel
Abstract:
Health Literacy is defined as the degree to which people have the capacity to obtain and understand information to make health decisions. Illustrated are three levels of health literacy: (1) Functional literacy refers to the transmission of information about e. g. physical activity and nutrition; (2) interactive literacy implies the development of personal and social skills to adopt health-related behaviour and (3) critical health literacy indicates advanced cognitive skills connected with personal empowerment to critically analyse health information, to define self-determined goals and taking action in various situations accordingly. The achievement of the third level refers to self-determination and autonomy which should be outcomes of exercise programs for overweight children as health-related behaviour change will occur and persist if it is autonomously motivated. Method: We adopted a quasi-experimental design with group (autonomy supportive coaching, control) and session (pre-test, intervention, post-test, and follow-up-test). Overweight and obese children and adolescents at the age of 8-14 years (N=40) received a 6-month (20 sessions) exercise program with autonomy supportive coaching implemented by the coaches and sandwiched between pre-test and post-test. All participants (N=92) completed the German version of the Basic Needs Satisfaction Scale Sport and Exercise. Additionally, we assessed the engagement in the exercise program by the MVPA (Moderate-to-Vigorous Physical Activity) and by the adherence and drop-out-rate. Results: Participants in the intervention group perceived their autonomy as moderate in the post-test and the follow-up-test. However, the psychological intervention failed to develop a high autonomy, as both groups show moderate perceived autonomy from the pre-test to the post-test. Participants in the intervention group were higher engaged in MVPA in the exercise program and they attend the program more regularly. Discussion: Young overweight and obese children and adolescents can acquire autonomy using autonomy supporting coaching. However, research identifying the extent they achieve critical health literacy is required to implement an autonomy-supportive coaching style into exercise programs for this target group.Keywords: autonomy support, coaching, health literacy, health promotion
Procedia PDF Downloads 48714692 Future Housing Energy Efficiency Associated with the Auckland Unitary Plan
Authors: Bin Su
Abstract:
The draft Auckland Unitary Plan outlines the future land used for new housing and businesses with Auckland population growth over the next thirty years. According to Auckland Unitary Plan, over the next 30 years, the population of Auckland is projected to increase by one million, and up to 70% of total new dwellings occur within the existing urban area. Intensification will not only increase the number of median or higher density houses such as terrace house, apartment building, etc. within the existing urban area but also change mean housing design data that can impact building thermal performance under the local climate. Based on mean energy consumption and building design data, and their relationships of a number of Auckland sample houses, this study is to estimate the future mean housing energy consumption associated with the change of mean housing design data and evaluate housing energy efficiency with the Auckland Unitary Plan.Keywords: Auckland Unitary Plan, building thermal design, housing design, housing energy efficiency
Procedia PDF Downloads 38614691 The Public Law Studies: Relationship Between Accountability, Environmental Education and Smart Cities
Authors: Aline Alves Bandeira, Luís Pedro Lima, Maria Cecília de Paula Silva, Paulo Henrique de Viveiros Tavares
Abstract:
Nowadays, the study of public policies regarding management efficiency is essential. Public policies are about what governments do or do not do, being an area that has grown worldwide, contributing through the knowledge of technologies and methodologies that monitor and evaluate the performance of public administrators. The information published on official government websites needs to provide for transparency and responsiveness of managers. Thus, transparency is a primordial factor for the execution of Accountability, providing, in this way, services to the citizen with the expansion of transparent, efficient, democratic information and that value administrative eco-efficiency. The ecologically balanced management of a Smart City must optimize environmental education, building a fairer society, which brings about equality in the use of quality environmental resources. Smart Cities add value in the construction of public management, enabling interaction between people, enhancing environmental education and the practical applicability of administrative eco-efficiency, fostering economic development and improving the quality of life.Keywords: accountability, environmental education, new public administration, smart cities
Procedia PDF Downloads 12814690 Volume Density of Power of Multivector Electric Machine
Authors: Aldan A. Sapargaliyev, Yerbol A. Sapargaliyev
Abstract:
Since the invention, the electric machine (EM) can be defined as oEM – one-vector electric machine, as it works due to one-vector inductive coupling with use of one-vector electromagnet. The disadvantages of oEM are large size and limited efficiency at low and medium power applications. This paper describes multi-vector electric machine (mEM) based on multi-vector inductive coupling, which is characterized by the increased surface area of the inductive coupling per EM volume, with a reduced share of inefficient and energy-consuming part of the winding, in comparison with oEM’s. Particularly, it is considered, calculated and compared the performance of three different electrical motors and their power at the same volumes and rotor frequencies. It is also presented the result of calculation of correlation between power density and volume for oEM and mEM. The method of multi-vector inductive coupling enables mEM to possess 1.5-4.0 greater density of power per volume and significantly higher efficiency, in comparison with today’s oEM, especially in low and medium power applications. mEM has distinct advantages, when used in transport vehicles such as electric cars and aircrafts.Keywords: electric machine, electric motor, electromagnet, efficiency of electric motor
Procedia PDF Downloads 33814689 Comparison of Growth Medium Efficiency into Stevia (Stevia rebaudiana Bertoni) Shoot Biomass and Stevioside Content in Thin-Layer System, TIS RITA® Bioreactor, and Bubble Column Bioreactor
Authors: Nurhayati Br Tarigan, Rizkita Rachmi Esyanti
Abstract:
Stevia (Stevia rebaudiana Bertoni) has a great potential to be used as a natural sweetener because it contains steviol glycoside, which is approximately 100 - 300 times sweeter than sucrose, yet low calories. Vegetative and generative propagation of S. rebaudiana is inefficient to produce stevia biomass and stevioside. One of alternative for stevia propagation is in vitro shoot culture. This research was conducted to optimize the best medium for shoot growth and to compare the bioconversion efficiency and stevioside production of S. rebaudiana shoot culture cultivated in thin layer culture (TLC), recipient for automated temporary immersion system (TIS RITA®) bioreactor, and bubble column bioreactor. The result showed that 1 ppm of Kinetin produced a healthy shoot and the highest number of leaves compared to BAP. Shoots were then cultivated in TLC, TIS RITA® bioreactor, and bubble column bioreactor. Growth medium efficiency was determined by yield and productivity. TLC produced the highest growth medium efficiency of S. rebaudiana, the yield was 0.471 ± 0.117 gbiomass.gsubstrate-1, and the productivity was 0.599 ± 0.122 gbiomass.Lmedium-1.day-1. While TIS RITA® bioreactor produced the lowest yield and productivity, 0.182 ± 0.024 gbiomass.gsubstrate-1 and 0.041 ± 0.0002 gbiomass.Lmedium-1.day-1 respectively. The yield of bubble column bioreactor was 0.354 ± 0.204 gbiomass.gsubstrate-1 and the productivity was 0,099 ± 0,009 gbiomass.Lmedium-1.day-1. The stevioside content from the highest to the lowest was obtained from stevia shoot which was cultivated on TLC, TIS RITA® bioreactor, and bubble column bioreactor; the content was 93,44 μg/g, 42,57 μg/g, and 23,03 μg/g respectively. All three systems could be used to produce stevia shoot biomass, but optimization on the number of nutrition and oxygen intake was required in each system.Keywords: bubble column, growth medium efficiency, Stevia rebaudiana, stevioside, TIS RITA®, TLC
Procedia PDF Downloads 26714688 A Novel Design Methodology for a 1.5 KW DC/DC Converter in EV and Hybrid EV Applications
Authors: Farhan Beg
Abstract:
This paper presents a method for the efficient implementation of a unidirectional or bidirectional DC/DC converter. The DC/DC converter is used essentially for energy exchange between the low voltage service battery and a high voltage battery commonly found in Electric Vehicle applications. In these applications, apart from cost, efficiency of design is an important characteristic. A useful way to reduce the size of electronic equipment in the electric vehicles is proposed in this paper. The technique simplifies the mechanical complexity and maximizes the energy usage using the latest converter control techniques. Moreover a bidirectional battery charger for hybrid electric vehicles is also implemented in this paper. Several simulations on the test system have been carried out in Matlab/Simulink environment. The results exemplify the robustness of the proposed design methodology in case of a 1.5 KW DC-DC converter.Keywords: DC-DC converters, electric vehicles, power electronics, direct current control
Procedia PDF Downloads 72714687 An Evaluation of Full-Scale Reinforced Concrete and Steel Girder Composite Members Using High Volume Fly-Ash
Authors: Sung-Won Yoo, Chul-Hyeon Kang, Kyoung-Tae Park, Hae-Sik Woo
Abstract:
Numerous studies were dedicated on the High Volume Fly-Ash (HVFA) concrete using high volume fly ash. The material properties of HVFA concrete have been the primordial topics of early studies, and interest shifted gradually toward the structural behavior of HVFA concrete such as elasticity modulus, stress-strain relationship, and structural behavior. However, structural studies consider small-scale members limited to the scope of reinforced concrete only. Therefore, in this paper, on the basis of recent studies on the structural behavior, 2 full-scale test members were manufactured with 7.5 m span length, fly ash replacement ratio of 50 % and concrete compressive strength of 50 MPa in order to evaluate the practicability of HVFA to real structures. In addition, 2 steel composite test members were also manufactured with span length of 3 m and using the same HVFA concrete for the same purpose. The test results of full-scale RC members showed that the practical use of HVFA on such structures is not hard despite small differences between test results and existing research results on the stress-strain relationship. The flexural test revealed very little difference between 50% fly ash concrete and general concrete in view of the similarity exhibited by the displacement and strain patterns. The experimental concrete shear strength being very close to that of design code, the existing design code can be applied. From the flexural test results of steel girder composite members, the composite behavior can be secured as much as that using normal concrete under the condition of sufficient arrangement of reinforcing bar.Keywords: composite, fly ash, full-scale, high volume
Procedia PDF Downloads 21714686 Response of Wheat (Triticum aestivum L.) to Deficit Irrigation Management in the Semi-Arid Awash Basin of Ethiopia
Authors: Gobena D. Bayisa, A. Mekonen, Megersa O. Dinka, Tilahun H. Nebi, M. Boja
Abstract:
Crop production in arid and semi-arid regions of Ethiopia is largely limited by water availability. Changing climate conditions and declining water resources increase the need for appropriate approaches to improve water use and find ways to increase production through reduced and more reliable water supply. In the years 2021/22 and 2022/23, a field experiment was conducted to evaluate the effect of limited irrigation water use on bread wheat (Triticum aestivum L.) production, water use efficiency, and financial benefits. Five irrigation treatments, i.e., full irrigation (100% ETc/ control), 85% ETc, 70% ETc, 55% ETc, and 40% ETc, were evaluated using a randomized complete block design (RCBD) with four replicates in the semi-arid climate condition of Awash basin of Ethiopia. Statistical analysis showed a significant effect of irrigation levels on wheat grain yield, water use efficiency, crop water response factor, economic profit, wheat grain quality, aboveground biomass, and yield index. The highest grain yield (5085 kg ha⁻¹) was obtained with 100% ETc irrigation (417.2 mm), and the lowest grain yield with 40% ETc (223.7 mm). Of the treatments, 70% ETc produced the higher wheat grain yield (4555 kg ha⁻¹), the highest water use efficiency (1.42 kg m⁻³), and the highest yield index (0.43). Using the saved water, wheat could be produced 23.4% more with a 70% ETc deficit than full irrigation on 1.38 ha of land, and it could get the highest profit (US$2563.9) and higher MRR (137%). The yield response factor and crop-water production function showed potential reductions associated with increased irrigation deficits. However, a 70% ETc deficit is optimal for increasing wheat grain yield, water use efficiency, and economic benefits of irrigated wheat production. The result indicates that deficit irrigation of wheat under the typical arid and semi-arid climatic conditions of the Awash Basin can be a viable irrigation management approach for enhancing water use efficiency while minimizing the decrease in crop yield could be considered effective.Keywords: crop-water response factor, deficit irrigation, water use efficiency, wheat production
Procedia PDF Downloads 6914685 Determination of Optimum Water Consumptive Using Deficit Irrigation Model for Barely: A Case Study in Arak, Iran
Authors: Mohsen Najarchi
Abstract:
This research was carried out in five fields (5-15 hectares) in Arak located in center of Iran, to determine optimum level of water consumed for Barely in four stages growth (vegetative, yield formation, flowering, and ripening). Actual evapotranspiration was calculated using measured water requirement in the fields. Five levels of water requirement equal to 50, 60, 70, 80, and 90 percents formed the treatments. To determine the optimum level of water requirement linear programming was used. The study showed 60 percent water requirement (40 percent deficit irrigation) has been the optimum level of irrigation for winter wheat in four stages of growth. Comparison between all of the treatments indicated above with normal condition (100% water requirement) shows increasing in water use efficiency. Although 40% deficit irrigation treatment lead to decrease of 38% in yield, net benefit was increasing in 11.37%. Furthermore, in comparison with normal condition, 70% of water requirement increased water use efficiency as 30%.Keywords: optimum, deficit irrigation, water use efficiency, evapotranspiration
Procedia PDF Downloads 39614684 Using Fly Ash Based Synthetic Zeolite Permeable Reactive Barrier to Remove Arsenic, Cadmium, and their Mixture from Aqueous Solution
Authors: Mozhgan Bahadory, Gholam-Hossein Rostami
Abstract:
Over the next quarter of a century, the US government and the private sector will spend billions of dollars annually to clean the contaminated sites from pollution such as petroleum products, heavy metals, and solvents organic compounds. During the past three decades, almost 750,000 sites that require remediation have been reported to the United States federal and state agencies. Out of these contamination sites, approximately 300,000 are still in need of remediation. In these sites, the most widespread forms of contamination are petroleum products and heavy metals. At least half of US Department of Defense, US Department of Energy, Superfund sites, and Resource Conservation and Recovery Act (RCRA) sites have been reported to contain heavy metals. Heavy metals most often found in the contaminated water are lead, mercury, chromium, cadmium, arsenic, and zinc. This investigation emphasizes the elimination of arsenic and cadmium from aqueous solution. During the past several years, we developed a novel material called Alkali-Activated fly ash Material Permeable Reactive Barrier (AAM-PRB), which includes fly ash, fine aggregates, coarse aggregates, activating chemicals, and water. AAM can be produced with high permeability, 10-1 cm/s, then crushed into pelletized form. Laboratory experiments showed that water containing 10 ppm, 100 ppm, and 1000 ppm of arsenic and cadmium ion passing through AAM-PRB reduced to less than 0.1 ppm. However, water containing 10,000 ppm arsenic ion passing through AAM- PRB shows that the breakthrough was achieved. The removal of the mixture of arsenic and cadmium from aqueous solutions was also tested by using AAM-PRB. The results indicate that the efficiency of AAM-PRB for simultaneous removal of arsenic and cadmium from 10 ppm, 100 ppm, and 1,000 ppm were marginally below that of arsenic alone. Still, it was significantly lower for cadmium from the aqueous solution. The basic science behind removing heavy metal and microstructural investigation AAM-PRB will be the focus of our future work.Keywords: arsenic, cadmium, contaminated water, fly ash, permeability, reactive barrier
Procedia PDF Downloads 7314683 BAN Logic Proof of E-passport Authentication Protocol
Authors: Safa Saoudi, Souheib Yousfi, Riadh Robbana
Abstract:
E-passport is a relatively new electronic document which maintains the passport features and provides better security. It deploys new technologies such as biometrics and Radio Frequency identification (RFID). The international civil aviation organization (ICAO) and the European union define mechanisms and protocols to provide security but their solutions present many threats. In this paper, a new mechanism is presented to strengthen e-passport security and authentication process. We propose a new protocol based on Elliptic curve, identity based encryption and shared secret between entities. Authentication in our contribution is formally proved with BAN Logic verification language. This proposal aims to provide a secure data storage and authentication.Keywords: e-passport, elliptic curve cryptography, identity based encryption, shared secret, BAN Logic
Procedia PDF Downloads 43514682 Hand Motion and Gesture Control of Laboratory Test Equipment Using the Leap Motion Controller
Authors: Ian A. Grout
Abstract:
In this paper, the design and development of a system to provide hand motion and gesture control of laboratory test equipment is considered and discussed. The Leap Motion controller is used to provide an input to control a laboratory power supply as part of an electronic circuit experiment. By suitable hand motions and gestures, control of the power supply is provided remotely and without the need to physically touch the equipment used. As such, it provides an alternative manner in which to control electronic equipment via a PC and is considered here within the field of human computer interaction (HCI).Keywords: control, hand gesture, human computer interaction, test equipment
Procedia PDF Downloads 31514681 Performance Investigation of Thermal Insulation Materials for Walls: A Case Study in Nicosia (Turkish Republic of North Cyprus)
Authors: L. Vafaei, McDominic Eze
Abstract:
The performance of thermal energy in homes and buildings is a significant factor in terms of energy efficiency of a building. In a large sense, the performance of thermal energy is dependent on many factors of which the amount of thermal insulation is at one end a considerable factor, as likewise the essence of mass and the wall thickness and also the thermal resistance of wall material. This study is aimed at illustrating the different wall system in Turkish Republic of North Cyprus (TRNC), acknowledge the problem and suggest a solution through comparing the effect of thermal radiation two model rooms- L1 (Ytong wall) and L2 (heat insulated wall using stone wool) set up for experimentation. The model room has four face walls. The study consists of two stage, the first test is to access the effect of solar radiation for south facing wall and the second stage is to test the thermal performance of Ytong and heat insulated wall, the effects of climatic condition during winter. The heat insulated wall contains material hollow brick, stone wool, and gypsum while the Ytong wall contains cement concrete, for the outer surface and the inner surface and Ytong stone. The total heat of the wall was determined, 7T-Type thermocouple was used with a data logger system to record the data, temperature change recorded at an interval of 10 minutes. The result obtained was that Ytong wall save more energy than the heat insulated wall at night while heat insulated wall saves energy during the day when intensity is at maximum.Keywords: heat insulation, hollow bricks, south facing, Ytong bricks wall
Procedia PDF Downloads 265