Search results for: retinal prosthetic devices
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2596

Search results for: retinal prosthetic devices

2566 Inhibition of Glutamate Carboxypeptidase Activity Protects Retinal Ganglionic Cell Death Induced by Ischemia-Reperfusion by Reducing the Astroglial Activation in Rat

Authors: Dugeree Otgongerel, Kyong Jin Cho, Yu-Han Kim, Sangmee Ahn Jo

Abstract:

Excessive activation of glutamate receptor is thought to be involved in retinal ganglion cell (RGC) death after ischemia- reperfusion damage. Glutamate carboxypeptidase II (GCPII) is an enzyme responsible for the synthesis of glutamate. Several studies showed that inhibition of GCPII prevents or reduces cellular damage in brain diseases. Thus, in this study, we examined the expression of GCPII in rat retina and the role of GCPII in acute high IOP ischemia-reperfusion damage of eye by using a GCPII inhibitor, 2-(phosphonomethyl) pentanedioic acid (2-PMPA). Animal model of ischemia-reperfusion was induced by raising the intraocular pressure for 60 min and followed by reperfusion for 3 days. Rats were randomly divided into four groups: either intra-vitreous injection of 2-PMPA (11 or 110 ng per eye) or PBS after ischemia-reperfusion, 2-PMPA treatment without ischemia-reperfusion and sham-operated normal control. GCPII immunoreactivity in normal rat retina was detected weakly in retinal nerve fiber layer (RNFL) and retinal ganglionic cell layer (RGL) and also inner plexiform layer (IPL) and outer plexiform layer (OPL) strongly where are co-stained with an anti-GFAP antibody, suggesting that GCPII is expressed mostly in Muller and astrocytes. Immunostaining with anti-BRN antibody showed that ischemia- reperfusion caused RGC death (31.5 %) and decreased retinal thickness in all layers of damaged retina, but the treatment of 2-PMPA twice at 0 and 48 hour after reperfusion blocked these retinal damages. GCPII level in RNFL layer was enhanced after ischemia-reperfusion but was blocked by PMPA treatment. This result was confirmed by western blot analysis showing that the level of GCPII protein after ischemia- reperfusion increased by 2.2- fold compared to control, but this increase was blocked almost completely by 110 ng PMPA treatment. Interestingly, GFAP immunoreactivity in the retina after ischemia- reperfusion followed by treatment with PMPA showed similar pattern to GCPII, increase after ischemia-reperfusion but reduction to the normal level by PMPA treatment. Our data demonstrate that increase of GCPII protein level after ischemia-reperfusion injury is likely to cause glial activation and/or retinal cell death which are mediated by glutamate, and GCPII inhibitors may be useful in treatment of retinal disorders in which glutamate excitotoxicity is pathogenic.

Keywords: glutamate carboxypepptidase II, glutamate excitotoxicity, ischemia-reperfusion, retinal ganglion cell

Procedia PDF Downloads 340
2565 Comparison of Early Silicon Oil Removal and Late Silicon Oil Removal in Patients With Rhegmatogenous Retinal Detachment

Authors: Hamidreza Torabi, Mohsen Moghtaderi

Abstract:

Introduction: Currently, deep vitrectomy with silicone oil tamponade is the standard treatment method for patients with Rhegmatogenous Retinal Detachment (RRD). After retinal repair, it is necessary to remove silicone oil from the eye, but the appropriate time to remove the oil and complications related to that time has been less studied. The aim of this study was to compare the results of the early removal of silicone oil with the delayed removal of silicone oil in patients with RRD. Method & material: Patients who were referred to the Ophthalmology Clinic of Baqiyatallah Hospital, Tehran, Iran, due to RRD with detached macula in 2021 & 2022 were evaluated. These patients were treated with deep vitrectomy and silicone oil tamponade. Patients whose retinas were attached after the passage of time were candidates for silicone oil removal (SOR) surgery. For patients in the early SOR group, SOR surgery was performed 3-6 months after the initial vitrectomy surgery, and for the late SOR group, SOR was performed after 6 months after the initial vitrectomy surgery. Results: In this study, 60 patients with RRD were evaluated. 23 (38.3%) patients were in the early group, and 37 (61.7%) patients were in the late group. Based on our findings, it was seen that the mean visual acuity of patients based on the Snellen chart in the early group (0.48 ± 0.23 Decimal) was better than the late group (0.33 ± 0.18 Decimal) (P-value=0.009). Retinal re-detachment has happened only in one patient with early SOR. Conclusion: Early removal of silicone oil (less than 6 months) from the eyes of patients undergoing RRD surgery has been associated with better vision results compared to late removal.

Keywords: retinal detachment, vitrectomy, silicone oil, silicone oil removal, visual acuity

Procedia PDF Downloads 76
2564 Exploring the Factors Affecting the Dependability of Mobile Devices in the Current World

Authors: Mayowa A. Sofowora, Seraphim D. Eyono Obono

Abstract:

In recent times the level of advancement in electronics and manufacturing technologies for portable electronic devices, especially for mobile devices such as cell phones, smartphones, personal digital assistants and tablet computers is unprecedented. Mobile devices have become indispensable to individuals, and businesses all over the world. The high level of manufacturing and production of mobile devices has led to the rapid release of newer and sleeker models with new features and capabilities. However, these newer models therefore render older models obsolete, and this pushes people to frequently replace their devices. The drawback of such frequent replacements is that a large number of devices are disposed and they end up as e-waste. The fact that e-waste constitutes a major hazard to human health and to the environment is the motivation behind this study whose aim is to develop a model of possible factors that affects the dependability of mobile devices which in turn leads to the obsolescence of these devices.

Keywords: dependability, mobile devices, obsolescence, e-waste

Procedia PDF Downloads 314
2563 A Case of Prosthetic Vascular-Graft Infection Due to Mycobacterium fortuitum

Authors: Takaaki Nemoto

Abstract:

Case presentation: A 69-year-old Japanese man presented with a low-grade fever and fatigue that had persisted for one month. The patient had an aortic dissection on the aortic arch 13 years prior, an abdominal aortic aneurysm seven years prior, and an aortic dissection on the distal aortic arch one year prior, which were all treated with artificial blood-vessel replacement surgery. Laboratory tests revealed an inflammatory response (CRP 7.61 mg/dl), high serum creatinine (Cr 1.4 mg/dL), and elevated transaminase (AST 47 IU/L, ALT 45 IU/L). The patient was admitted to our hospital on suspicion of prosthetic vascular graft infection. Following further workups on the inflammatory response, an enhanced chest computed tomography (CT) and a non-enhanced chest DWI (MRI) were performed. The patient was diagnosed with a pulmonary fistula and a prosthetic vascular graft infection on the distal aortic arch. After admission, the patient was administered Ceftriaxion and Vancomycine for 10 days, but his fever and inflammatory response did not improve. On day 13 of hospitalization, a lung fistula repair surgery and an omental filling operation were performed, and Meropenem and Vancomycine were administered. The fever and inflammatory response continued, and therefore we took repeated blood cultures. M. fortuitum was detected in a blood culture on day 16 of hospitalization. As a result, we changed the treatment regimen to Amikacin (400 mg/day), Meropenem (2 g/day), and Cefmetazole (4 g/day), and the fever and inflammatory response began to decrease gradually. We performed a test of sensitivity for Mycobacterium fortuitum, and found that the MIC was low for fluoroquinolone antibacterial agent. The clinical course was good, and the patient was discharged after a total of 8 weeks of intravenous drug administration. At discharge, we changed the treatment regimen to Levofloxacin (500 mg/day) and Clarithromycin (800 mg/day), and prescribed these two drugs as a long life suppressive therapy. Discussion: There are few cases of prosthetic vascular graft infection caused by mycobacteria, and a standard therapy remains to be established. For prosthetic vascular graft infections, it is ideal to provide surgical and medical treatment in parallel, but in this case, surgical treatment was difficult and, therefore, a conservative treatment was chosen. We attempted to increase the treatment success rate of this refractory disease by conducting a susceptibility test for mycobacteria and treating with different combinations of antimicrobial agents, which was ultimately effective. With our treatment approach, a good clinical course was obtained and continues at the present stage. Conclusion: Although prosthetic vascular graft infection resulting from mycobacteria is a refractory infectious disease, it may be curative to administer appropriate antibiotics based on the susceptibility test in addition to surgical treatment.

Keywords: prosthetic vascular graft infection, lung fistula, Mycobacterium fortuitum, conservative treatment

Procedia PDF Downloads 156
2562 On the Volume of Ganglion Cell Stimulation in Visual Prostheses by Finite Element Discretization

Authors: Diego Luján Villarreal

Abstract:

Visual prostheses are designed to repair some eyesight in patients blinded by photoreceptor diseases, such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD). Electrode-to-cell proximity has drawn attention due to its implications on secure single-localized stimulation. Yet, few techniques are available for understanding the relationship between the number of cells activated and the current injection. We propose an answering technique by solving the governing equation for time-dependent electrical currents using finite element discretization to obtain the volume of stimulation.

Keywords: visual prosthetic devices, volume for stimulation, FEM discretization, 3D simulation

Procedia PDF Downloads 73
2561 Methodology for Obtaining Static Alignment Model

Authors: Lely A. Luengas, Pedro R. Vizcaya, Giovanni Sánchez

Abstract:

In this paper, a methodology is presented to obtain the Static Alignment Model for any transtibial amputee person. The proposed methodology starts from experimental data collected on the Hospital Militar Central, Bogotá, Colombia. The effects of transtibial prosthesis malalignment on amputees were measured in terms of joint angles, center of pressure (COP) and weight distribution. Some statistical tools are used to obtain the model parameters. Mathematical predictive models of prosthetic alignment were created. The proposed models are validated in amputees and finding promising results for the prosthesis Static Alignment. Static alignment process is unique to each subject; nevertheless the proposed methodology can be used in each transtibial amputee.

Keywords: information theory, prediction model, prosthetic alignment, transtibial prosthesis

Procedia PDF Downloads 256
2560 An Unusual Occurrence: Typhoid Retinitis with Kyrieleis' Vasculitis

Authors: Aditya Sethi, Vaibhav Sethi, Shenouda Girgis

Abstract:

We present a case of a 31-year-old female who presented with a three week history of left eye blurry vision following a fever. She was diagnosed with Typhoid fever, confirmed by a positive Widal test report. On examination, her best corrected visual acuity in the right eye was 20/20 and in the left eye was 20/60. Fundus examination of the right eye showed a focal area of retinitis with retinal haemorrhages along the superior arcade within the macula. There was also focal area of retinitis with superficial retinal haemorrhages along the superior arcade vessels. There was also presence of multiple yellowish white exudates within the adjacent retinal artery arranged in a beaded pattern, suggestive of Kyrieleis' vasculitis. Optical Coherence Tomography (OCT) of the left eye demonstrated cystoid macula edema with serous foveal detachment.

Keywords: typhoid retinitis, Kyrieleis’ vasculitis, immune-mediated retinitis, post-fever retinitis, typhoid retinopathy, retinitis

Procedia PDF Downloads 178
2559 External Retinal Prosthesis Image Processing System Used One-Cue Saliency Map Based on DSP

Authors: Yili Chen, Jixiang Fu, Zhihua Liu, Zhicheng Zhang, Rongmao Li, Nan Fu, Yaoqin Xie

Abstract:

Retinal prothesis is designed to help the blind to get some sight.It is made up of internal part and external part.In external part ,there is made up of camera, image processing, and RF transmitter.In internal part, there is RF receiver, implant chip,micro-electrode.The image got from the camera should be processed by suitable stragies to corresponds to stimulus the electrode.Nowadays, the number of the micro-electrode is hundreds and we don’t know the mechanism how the elctrode stimulus the optic nerve, an easy way to the hypothesis is that the pixel in the image is correspondence to the electrode.So it is a question how to get the important information of the image captured from the picture.There are many strategies to experimented to get the most important information as soon as possible, due to the real time system.ROI is a useful algorithem to extract the region of the interest.Our paper will explain the details of the orinciples and functions of the ROI.And based on this, we simplified the ROI algrithem,and used it in outside image prcessing DSP system of the retinal prothesis.Results show that our image processing stratiges is suitable for real-time retinal prothesis and can cut redundant information and help useful information to express in the low-size image.

Keywords: image processing, region of interest, saliency map, low-size image, useful information express, cut redundant information in image

Procedia PDF Downloads 282
2558 Teaching Prosthetic and Orthotics in Palestine: Between Reality and Challenges

Authors: Ahmad Dawabsheh

Abstract:

The science of prosthetics is a renewable science that serves all humanity, regardless of gender, religion and race, and its causes are many: wars, conflicts, traffic accidents, and others. The researcher believes that there are challenges facing the specialization, including that society views a negative view of the amputee, especially if it is a female. This research aims to focus on the reality of teaching prosthetics in Palestine, especially in the Arab American University, as it is the only major. As well as the challenges facing this major: financial, human, academic, laboratories, and others. The researcher used the descriptive and analytical approach, which is the closest approach to studying the subject. The researcher believes that there is a failure on the part of the state and the Ministry of Health in this matter. In addition to the lack of societal culture, as well as the large quantities of prosthetic fittings.

Keywords: prothetics, orthotics, Arab American University, Palestine

Procedia PDF Downloads 142
2557 Resistive Switching Characteristics of Resistive Random Access Memory Devices after Furnace Annealing Processes

Authors: Chi-Yan Chu, Kai-Chi Chuang, Huang-Chung Cheng

Abstract:

In this study, the RRAM devices with the TiN/Ti/HfOx/TiN structure were fabricated, then the electrical characteristics of the devices without annealing and after 400 °C and 500 °C of the furnace annealing (FA) temperature processes were compared. The RRAM devices after the FA’s 400 °C showed the lower forming, set and reset voltages than the other devices without annealing. However, the RRAM devices after the FA’s 500 °C did not show any electrical characteristics because the TiN/Ti/HfOx/TiN device was oxidized, as shown in the XPS analysis. From these results, the RRAM devices after the FA’s 400 °C showed the best electrical characteristics.

Keywords: RRAM, furnace annealing (FA), forming, set and reset voltages, XPS

Procedia PDF Downloads 371
2556 The Predictability of Three Implants to Support a Fixed Prosthesis in the Edentulous Mandible

Authors: M. Hirani, M. Devine, O. Obisesan, C. Bryant

Abstract:

Introduction: The use of four or more implants to support a fixed prosthesis in the edentulous mandible is well documented, with high levels of clinical outcomes recorded. Despite this, the use of three implant-supported fixed prostheses offers the potential to deliver a more cost-effective method of oral rehabilitation in the lower arch, an important consideration given that edentulism is most prevalent in low-income subpopulations. The purpose of this study aimed to evaluate the implant and prosthetic survival rate, changes in marginal bone level, and patient satisfaction associated with a three-implant-supported fixed prosthesis for rehabilitation of the edentulous mandible over a follow-up period of at least one year. Methods: A comprehensive literature search was performed to evaluate studies that met the selection criteria. The information extracted included the study design and population, participant demographics, observation period, loading protocol, and the number of implants placed together with the required outcome measures. Mean values and standard deviations (SD) were calculated using SPSS® (IBM Corporation, New York, USA), and the level of statistical significance across all comparative studies described was set at P < 0.05. Results: The eligible studies included a total of 1968 implants that were placed in 652 patients. The subjects ranged in age from 33-89 years, with a mean of 63.2 years. The mean cumulative implant and prosthetic survival rates were 95.5% and 96.2%, respectively, over a mean follow-up period of 3.25 years. The mean marginal bone loss recorded was 1.04 mm, and high patient satisfaction rates were reported across the studies. Conclusion: Current evidence suggests that a three implant-supported fixed prosthesis for the edentulous mandible is a successful treatment strategy presenting high implant and prosthetic survival rates over the short-to-medium term. Further well-designed controlled clinical trials are required to evaluate longer-term outcomes, with supplemental data correlating implant dimensions and prosthetic design.

Keywords: implants, mandible, fixed, prosthesis

Procedia PDF Downloads 131
2555 Ultrasonography of Low Extremities Veins Before and After Replacement of Knee Joint by Endoprosthesis

Authors: A. V. Alabut, V. D. Sikilinda, N. J. Nelasov, O. L. Eroshenko, M. N. Morgunov, I. V. Koroleva

Abstract:

We have analyzed the results of treatment of 204 patients with knee prosthetic arthroplasty. For the purpose of active delineation of vascular pathology triplex sonography of arterial and venous vessels of low extremities was performed in all cases in the preoperative period. When it was necessary, reconstructive vascular surgery was implemented to improve peripheral circulation and reduce the hazard of thrombosis after knee replacement. The combination of specific and nonspecific methods of thromboprophylaxis was used in perioperative period. On 7-10 day and 2.5-3 month after prosthetic arthroplasty, all patients iteratively underwent triple sonography. In case of detection of floating thrombus, urgent venous ligation was performed. Active diagnostics of venous thrombosis gave the opportunity to avoid fatal pulmonary embolism.

Keywords: knee replacement, venous thrombosis, pulmonary embolism, vascular surgery

Procedia PDF Downloads 368
2554 Characterization of Retinal Pigmented Cell Epithelium Cell Sheet Cultivated on Synthetic Scaffold

Authors: Tan Yong Sheng Edgar, Yeong Wai Yee

Abstract:

Age-related macular degeneration (AMD) is one of the leading cause of blindness. It can cause severe visual loss due to damaged retinal pigment epithelium (RPE). RPE is an important component of the retinal tissue. It functions as a transducing boundary for visual perception making it an essential factor for sight. The RPE also functions as a metabolically complex and functional cell layer that is responsible for the local homeostasis and maintenance of the extra photoreceptor environment. Thus one of the suggested method of treating such diseases would be regenerating these RPE cells. As such, we intend to grow these cells using a synthetic scaffold to provide a stable environment that reduces the batch effects found in natural scaffolds. Stiffness of the scaffold will also be investigated to determine the optimal Young’s modulus for cultivating these cells. The cells will be generated into a monolayer cell sheet and their functions such as formation of tight junctions and gene expression patterns will be assessed to evaluate the cell sheet quality compared to a native RPE tissue.

Keywords: RPE, scaffold, characterization, biomaterials, colloids and nanomedicine

Procedia PDF Downloads 435
2553 Automatic Method for Exudates and Hemorrhages Detection from Fundus Retinal Images

Authors: A. Biran, P. Sobhe Bidari, K. Raahemifar

Abstract:

Diabetic Retinopathy (DR) is an eye disease that leads to blindness. The earliest signs of DR are the appearance of red and yellow lesions on the retina called hemorrhages and exudates. Early diagnosis of DR prevents from blindness; hence, many automated algorithms have been proposed to extract hemorrhages and exudates. In this paper, an automated algorithm is presented to extract hemorrhages and exudates separately from retinal fundus images using different image processing techniques including Circular Hough Transform (CHT), Contrast Limited Adaptive Histogram Equalization (CLAHE), Gabor filter and thresholding. Since Optic Disc is the same color as the exudates, it is first localized and detected. The presented method has been tested on fundus images from Structured Analysis of the Retina (STARE) and Digital Retinal Images for Vessel Extraction (DRIVE) databases by using MATLAB codes. The results show that this method is perfectly capable of detecting hard exudates and the highly probable soft exudates. It is also capable of detecting the hemorrhages and distinguishing them from blood vessels.

Keywords: diabetic retinopathy, fundus, CHT, exudates, hemorrhages

Procedia PDF Downloads 272
2552 Segmenting 3D Optical Coherence Tomography Images Using a Kalman Filter

Authors: Deniz Guven, Wil Ward, Jinming Duan, Li Bai

Abstract:

Over the past two decades or so, Optical Coherence Tomography (OCT) has been used to diagnose retina and optic nerve diseases. The retinal nerve fibre layer, for example, is a powerful diagnostic marker for detecting and staging glaucoma. With the advances in optical imaging hardware, the adoption of OCT is now commonplace in clinics. More and more OCT images are being generated, and for these OCT images to have clinical applicability, accurate automated OCT image segmentation software is needed. Oct image segmentation is still an active research area, as OCT images are inherently noisy, with the multiplicative speckling noise. Simple edge detection algorithms are unsuitable for detecting retinal layer boundaries in OCT images. Intensity fluctuation, motion artefact, and the presence of blood vessels also decrease further OCT image quality. In this paper, we introduce a new method for segmenting three-dimensional (3D) OCT images. This involves the use of a Kalman filter, which is commonly used in computer vision for object tracking. The Kalman filter is applied to the 3D OCT image volume to track the retinal layer boundaries through the slices within the volume and thus segmenting the 3D image. Specifically, after some pre-processing of the OCT images, points on the retinal layer boundaries in the first image are identified, and curve fitting is applied to them such that the layer boundaries can be represented by the coefficients of the curve equations. These coefficients then form the state space for the Kalman Filter. The filter then produces an optimal estimate of the current state of the system by updating its previous state using the measurements available in the form of a feedback control loop. The results show that the algorithm can be used to segment the retinal layers in OCT images. One of the limitations of the current algorithm is that the curve representation of the retinal layer boundary does not work well when the layer boundary is split into two, e.g., at the optic nerve, the layer boundary split into two. This maybe resolved by using a different approach to representing the boundaries, such as b-splines or level sets. The use of a Kalman filter shows promise to developing accurate and effective 3D OCT segmentation methods.

Keywords: optical coherence tomography, image segmentation, Kalman filter, object tracking

Procedia PDF Downloads 482
2551 A Study of Issues and Mitigations on Distributed Denial of Service and Medical Internet of Things Devices

Authors: Robin Singh, Jing-Chiou Liou

Abstract:

The Internet of Things (IoT) devices are being used heavily as part of our everyday routines. Through improved communication and automated procedures, its popularity has assisted users in raising the quality of work. These devices are used in healthcare in order to better collect the patient’s data for their treatment. They are generally considered safe and secure. However, there is some possibility that some loopholes do exist which manufacturers do need to identify before some hacker takes advantage of them. For this study, we focused on two medical IoT devices which are pacemakers and hearing aids. The aim of this paper is to identify if there is any likelihood of these medical devices being hijacked and used as a botnet in Distributed Denial-Of Service attacks. Moreover, some mitigation strategies are being proposed to better secure

Keywords: cybersecurity, DDoS, IoT, medical devices

Procedia PDF Downloads 86
2550 Computer-Aided Exudate Diagnosis for the Screening of Diabetic Retinopathy

Authors: Shu-Min Tsao, Chung-Ming Lo, Shao-Chun Chen

Abstract:

Most diabetes patients tend to suffer from its complication of retina diseases. Therefore, early detection and early treatment are important. In clinical examinations, using color fundus image was the most convenient and available examination method. According to the exudates appeared in the retinal image, the status of retina can be confirmed. However, the routine screening of diabetic retinopathy by color fundus images would bring time-consuming tasks to physicians. This study thus proposed a computer-aided exudate diagnosis for the screening of diabetic retinopathy. After removing vessels and optic disc in the retinal image, six quantitative features including region number, region area, and gray-scale values etc… were extracted from the remaining regions for classification. As results, all six features were evaluated to be statistically significant (p-value < 0.001). The accuracy of classifying the retinal images into normal and diabetic retinopathy achieved 82%. Based on this system, the clinical workload could be reduced. The examination procedure may also be improved to be more efficient.

Keywords: computer-aided diagnosis, diabetic retinopathy, exudate, image processing

Procedia PDF Downloads 268
2549 The Effects of Prosthetic Leg Stiffness on Gait, Comfort, and Satisfaction: A Review of Mechanical Engineering Approaches

Authors: Kourosh Fatehi, Niloofar Hanafi

Abstract:

One of the challenges in providing optimal prosthetic legs for lower limb amputees is to select the appropriate foot stiffness that suits their individual needs and preferences. Foot stiffness affects various aspects of walking, such as stability, comfort, and energy expenditure. However, the current prescription process is largely based on trial-and-error, manufacturer recommendations, or clinician judgment, which may not reflect the prosthesis user’s subjective experience or psychophysical sensitivity. Therefore, there is a need for more scientific and technological tools to measure and understand how prosthesis users perceive and prefer different foot stiffness levels, and how this preference relates to clinical outcomes. This review covers how to measure and design lower leg prostheses based on user preference and foot stiffness. It also explores how these factors affect walking outcomes and quality of life, and identifies the current challenges and gaps in this field from a mechanical engineering standpoint.

Keywords: perception, preference, prosthetics, stiffness

Procedia PDF Downloads 81
2548 Analysis of a Single Motor Finger Mechanism for a Prosthetic Hand

Authors: Shaukat Ali, Kanber Sedef, Mustafa Yilmaz

Abstract:

This work analyzes a finger mechanism for a prosthetic hand that will help in improving the living standards of people who have lost their hands for a variety of reasons. The finger mechanism is single degree of freedom and hence has advantages such as compact size, reduced mass and less energy consumption. The proposed finger mechanism is a six bar linkage actuated by a single motor. The kinematic, static and dynamic analyses have been done by using the conventional methods of mechanism analysis. The kinematic results present the motion of the proposed finger mechanism and location of the fingertip. The static and dynamic analyses provide the useful information about the gripping force at the fingertip for various configurations and the selection of motor that will move the finger over its range of configuration. This single motor finger mechanism is simple and resembles the human finger’s motion suitable for grasping operation. This study can be used in the optimization of geometrical parameters of the proposed mechanism to obtain the desired configurations with minimum torque and enhanced griping.

Keywords: dynamics, finger mechanism, grasping, kinematics

Procedia PDF Downloads 358
2547 Influence of ABCB1 2677G > T Single Nucleotide Polymorphism on Warfarin Maintenance Therapy among Patients with Prosthetic Heart Valve

Authors: M. G. Gopisankar, A. Surendiran, M. Hemachandren

Abstract:

The dose requirement of warfarin to achieve target INR range varies in patients with prosthetic heart valve. This variation in is affected by both genetic and non-genetic factors. Earlier studies have identified role of CYP2C9 and VKORC1 genetic polymorphisms on warfarin dose requirement. Warfarin being a substrate for drug transporter, P-glycoprotein coded by ABCB1 gene, may also be influenced by its genetic polymorphisms. This study was aimed to study the effect of single nucleotide polymorphism (SNP), ABCB1 2677G > T on warfarin maintenance dose requirement in patients with steady-state International Normalized Ratio (INR). The median dose requirement was significantly different between the genotype groups GG vs. GT (35 ± 20; 42.5 ± 18, p < 0.05), GG vs. TT (35 ± 20; 41.25 ± 25, p<0.05). There was no significant difference between GT vs. TT. In conclusion, patients with variant allele require a higher weekly maintenance dose of warfarin compared to patients without variant allele.

Keywords: warfarin pharamcogenetics, pharmacogenomics of warfarin, ABCB1 and warfarin, pglycoprotein and warfarin

Procedia PDF Downloads 260
2546 Development of Underactuated Robot Hand Using Cross Section Deformation Spring

Authors: Naoki Saito, Daisuke Kon, Toshiyuki Sato

Abstract:

This paper describes an underactuated robot hand operated by low-power actuators. It can grasp objects of various shapes using easy operations. This hand is suitable for use as a lightweight prosthetic hand that can grasp various objects using few input channels. To realize operations using a low-power actuator, a cross section deformation spring is proposed. The design procedure of the underactuated robot finger is proposed to realize an adaptive grasping movement. The validity of this mechanism and design procedure are confirmed through an object grasping experiment. Results demonstrate the effectiveness of a cross section deformation spring in reducing the actuator power. Moreover, adaptive grasping movement is realized by an easy operation.

Keywords: robot hand, underactuated mechanism, cross-section deformation spring, prosthetic hand

Procedia PDF Downloads 372
2545 Impact of FACTS Devices on Power Networks Reliability

Authors: Alireza Alesaadi

Abstract:

Flexible AC transmission system (FACTS) devices have an important rule on expnded electrical transmission networks. In this paper, the effect of these diveces on reliability of electrical networks is studied and it is shown that using of FACTS devices can improve the relibiability of power networks, significantly.

Keywords: FACTS devices, power networks, reliability

Procedia PDF Downloads 427
2544 Modeling and Design of Rectenna for Low Power Medical Implants

Authors: Madhav Pant, Khem N. Poudel

Abstract:

Wireless power transfer is continuously becoming more powerful and compact in medical implantable devices and the wide range of applications. A rectenna is designed for wireless power transfer technique that can be applied to medical implant devices. The experiment is performed using ANSYS HFSS, a full wave electromagnetic simulation. The dipole antenna combinations operating at 2.4 GHz are used for wireless power transfer and the maximum DC voltage reception by the implant considering International Commission on Non-Ionizing Radiation Protection (ICNIRP) regulation. The power receiving dipole antenna is placed inside the cylindrical geometry having the similar properties of the human body at the frequency of 2.4 GHz. Our design can provide the power at the depth of 5 mm skin and 5mm of bone for the implant. The voltage doubler/quadrupler rectifier in ANSYS Simplorer is used to calculate the exact DC current utilized by implant inside the human body. The qualitative design and analysis of this wireless power transfer method could also be used for other biomedical implants systems such as cardiac pacemaker, insulin pump, and retinal implants.

Keywords: dipole antenna, medical implants, wireless power transfer, rectifier

Procedia PDF Downloads 172
2543 Central Retinal Venous Occlusion Associated O Bilateral Optic Nerve Infiltration Revealing Relapse Of An Acute Lymphoblastic Leukemia

Authors: Fendouli Ines, Zaafrane Nesrine, Mhamdi Hana, Knani Leila, Ghorbel Mohamed

Abstract:

Introduction: Ocular infiltration of leukemia can involve orbit, uveal tract, retina and optic nerve. It may result from direct ocular infiltration by leukemic cells or indirect ocular involvement resulting from secondary hematologic changes, opportunistic infections and complications of various modalities of therapy. We here in report a case of central venous retinal occlusion associated to optic nerve infiltration as presenting signs of a relapse of acute lymphoblastic leukemia. Case Report: A twelve-year-old male -patient of acute B lymphoblastic leukemia presented with headaches and bilateral blurred vision in the left ee. Ophthalmic examination showed a visual acuity reduced to counting fingers in the right eye and no light perception in the left eye. Funduscopy revealed a voluminous disc edema surrounded by retinal haemorrhages in the right eye, and venous tortusities, papillary edema, and hemorrages suggesting central retinal venous occlusion in the LE. Swept source optical coherence tomography revealed a serous retinal detachment in the RE and .hyperreflective inner layers with macular edema in the left eye. Cerebro-orbital MRI showed bilateral thickened left optic nerve. There were no radiological signs of true papillary edema due to intracranial hypertension secondary to central nervous system involvement. Myelogram and lumbar punction demonstrated blast infiltration and confirmed ocular relapse of the leukemia. Conclusion: Ocular involvement lymphoblastic acute leukemias decreased since the introduction of a systematic prophylactic treatment of central nervous system. Periodic ophthalmic examination is necessary to allow early diagnosis and treatment.

Keywords: acute leukemia, optic nerve, infiltration, relapse

Procedia PDF Downloads 90
2542 Reconfigurable Ubiquitous Computing Infrastructure for Load Balancing

Authors: Khaled Sellami, Lynda Sellami, Pierre F. Tiako

Abstract:

Ubiquitous computing helps make data and services available to users anytime and anywhere. This makes the cooperation of devices a crucial need. In return, such cooperation causes an overload of the devices and/or networks, resulting in network malfunction and suspension of its activities. Our goal in this paper is to propose an approach of devices reconfiguration in order to help to reduce the energy consumption in ubiquitous environments. The idea is that when high-energy consumption is detected, we proceed to a change in component distribution on the devices to reduce and/or balance the energy consumption. We also investigate the possibility to detect high-energy consumption of devices/network based on devices abilities. As a result, our idea realizes a reconfiguration of devices aimed at reducing the consumption of energy and/or load balancing in ubiquitous environments.

Keywords: ubiquitous computing, load balancing, device energy consumption, reconfiguration

Procedia PDF Downloads 275
2541 Improve of Power Quality in Electrical Network Using STATCOM

Authors: A. R. Alesaadi

Abstract:

Flexible AC transmission system (FACTS) devices have an important rule on expended electrical transmission networks. These devices can provide control of one or more AC transmission system parameters to enhance controllability and increase power transfer capability. In this paper the effect of these devices on reliability of electrical networks is studied and it is shown that using of FACTS devices can improve the reliability of power networks and power quality in electrical networks, significantly.

Keywords: FACTS devices, power networks, power quality, STATCOM

Procedia PDF Downloads 668
2540 Study on Stability and Wear in a Total Hip Prostheses

Authors: Virgil Florescu, Lucian Capitanu

Abstract:

The studies performed by the author and presented here focus mainly on the FE simulation of some relevant phenomena related to stability of orthopedic implants, especially those components of Total Hip Prostheses. The objectives are to study the mechanisms of achieving stability of acetabular prosthetic components and the influence of some characteristic parameters, to evaluate the effect of femoral stem fixation modality on the stability of prosthetic component and to predict long-term behavior, to analyze a critical phenomena which influence the loading transfer mechanism through artificial joints and could lead to aseptic loosening – the wear of joint frictional surfaces. After a theoretical background an application is made considering only three activities: normal walking, stair ascending and stair descending. For each activity, this function is maximized in a different locations: if for normal walking the maxima is in the superior-posterior part of the acetabular cup, for stair descending this maxim value could be located rather in the superior-anterior part, for stair ascending being even closer to the central area of the cup.

Keywords: THA, acetabular stability, FEM simulation, stresses and displacements, wear tests, wear simulation

Procedia PDF Downloads 269
2539 Usage and Benefits of Handheld Devices as Educational Tools in Higher Institutions of Learning in Lagos State, Nigeria

Authors: Abiola A. Sokoya

Abstract:

Handheld devices are now in use as educational tools for learning in most of the higher institutions, because of the features and functions which can be used in an academic environment. This study examined the usage and the benefits of handheld devices as learning tools. A structured questionnaire was used to collect data, while the data collected was analyzed using simple percentage. It was, however, observed that handheld devices offer numerous functions and application for learning, which could improve academic performance of students. Students are now highly interested in using handheld devices for mobile learning apart from making and receiving calls. The researchers recommended that seminars be organized for students on functions of some common handheld devices that can aid learning for academic purposes. It is also recommended that management of each higher institution should make appropriate policies in-line with the usage of handheld technologies to enhance mobile learning. Government should ensure that appropriate policies and regulations are put in place for the importation of high quality handheld devices into the country, Nigeria being a market place for the technologies. By this, using handheld devices for mobile learning will be enhanced.

Keywords: handheld devices, educational tools, mobile e- learning, usage, benefits

Procedia PDF Downloads 228
2538 Producer’s Liability for Defective Medical Devices in Light of Council Directive 85/374/EEC

Authors: Vera Lúcia Raposo

Abstract:

Medical devices are products used for medical purposes and aimed to operate in the human body, sometimes even inside the human body. Therefore, they can become particularly risky products, and some of the injuries caused by medical devices can have serious effects on the person’s health or body, even leading to death. Because they fit in the category of 'products' as described in Article 2 of Council Directive 85/374/EEC of 25 July 1985, concerning liability for defective products, the liability of the manufacturer of medical devices follows the rules of strict liability as long as one of the defects covered by the directive is at stake. The directive is not concerned with the product’s efficiency, but instead with the product’s safety, although in what regards medical devices (the same being valid for drugs) the two concepts frequently go together, and a lack of efficiency can result in a lack of safety. In the particular case of medical devices, the most debatable defects are the ones related with erroneous or non-existing information and the so-called development defects. This paper analyses how directive 85/374/EEC applies to medical devices, which defects are covered by its regulation, and which criteria can be used to evaluate the product’s safety. Some issues are still to be clarified, even though the decisions from the European Court of Justice and from national courts are valuable tools to understand the scope of directive 85/374/EEC in what regards medical devices.

Keywords: medical devices, producer’s liability, product safety, strict liability

Procedia PDF Downloads 325
2537 Support Vector Machine Based Retinal Therapeutic for Glaucoma Using Machine Learning Algorithm

Authors: P. S. Jagadeesh Kumar, Mingmin Pan, Yang Yung, Tracy Lin Huan

Abstract:

Glaucoma is a group of visual maladies represented by the scheduled optic nerve neuropathy; means to the increasing dwindling in vision ground, resulting in loss of sight. In this paper, a novel support vector machine based retinal therapeutic for glaucoma using machine learning algorithm is conservative. The algorithm has fitting pragmatism; subsequently sustained on correlation clustering mode, it visualizes perfect computations in the multi-dimensional space. Support vector clustering turns out to be comparable to the scale-space advance that investigates the cluster organization by means of a kernel density estimation of the likelihood distribution, where cluster midpoints are idiosyncratic by the neighborhood maxima of the concreteness. The predicted planning has 91% attainment rate on data set deterrent on a consolidation of 500 realistic images of resolute and glaucoma retina; therefore, the computational benefit of depending on the cluster overlapping system pedestal on machine learning algorithm has complete performance in glaucoma therapeutic.

Keywords: machine learning algorithm, correlation clustering mode, cluster overlapping system, glaucoma, kernel density estimation, retinal therapeutic

Procedia PDF Downloads 254