Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 513
Search results for: stabilized zirconia ceramics
3 Challenging Airway Management for Tracheal Compression Due to a Rhabdomyosarcoma
Authors: Elena Parmentier, Henrik Endeman
Abstract:
Introduction: Large mediastinal masses often present with diagnostic and clinical challenges due to compression of the respiratory and hemodynamic system. We present a case of a mediastinal mass with symptomatic mechanical compression of the trachea, resulting in challenging airway management. Methods: We present a case of 66-year-old male, complaining of progressive dysphagia. Initial esophagogastroscopy revealed a stenosis secondary to external compression, biopsies were inconclusive. Additional CT scan showed a large mediastinal mass of unknown origin, situated between the vertebrae and esophagus. Symptoms progressed and patient developed dyspnea and stridor. A new CT showed quick growth of the mass with compression of the trachea, subglottic to just above the carina. A tracheal covered stent was successfully placed. Endobronchial ultrasound revealed a large irregular mass without tracheal invasion, biopsies were taken. 4 days after stent placement, the patients’ condition deteriorated with worsening of stridor, dyspnea and desaturation. Migration of the tracheal stent into the right main bronchus was seen on chest X ray, with obstruction of the left main bronchus and secondary atelectasis. Different methods have been described in the literature for tracheobronchial stent removal (surgical, endoscopic, fluoroscopyguided), our first choice in this case was flexible bronchoscopy. However, this revealed tracheal compression above the migrated stent and passage of the scope occurred impossible. Patient was admitted to the ICU, high-flow nasal oxygen therapy was started and the situation stabilized, giving time for extensive assessment and preparation of the airway management approach. Close cooperation between the intensivist, pulmonologist, anesthesiologist and otorhinolaryngologist was essential. Results: In case of sudden deterioration, a protocol for emergency situations was made. Given the increased risk of additional tracheal compression after administration of neuromuscular blocking agents, an approach with awake fiberoptic intubation maintaining spontaneous ventilation was proposed. However, intubation without retrieval of the tracheal stent was found undesirable due to expected massive shunting over the left atelectatic lung. As rescue option, assistance of extracorporeal circulation was considered and perfusionist was kept on standby. The patient stayed stable and was transferred to the operating theatre. High frequency jet ventilation under general anesthesia resulted in desaturations up to 50%, making rigid bronchoscopy impossible. Subsequently an endotracheal tube size 8 could be placed successfully and the stent could be retrieved via bronchoscopy over (and with) the tube, after which the patient was reintubated. Finally, a tracheostomy (Shiley™ Tracheostomy Tube With Cuff, size 8) was placed, fiberoptic control showed a patent airway. Patient was readmitted to the ICU and could be quickly weaned of the ventilator. Pathology was positive for rhabdomyosarcoma, without indication for systemic therapy. Extensive surgery (laryngectomy, esophagectomy) was suggested, but patient refused and palliative care was started. Conclusion: Due to meticulous planning in an interdisciplinary team, we showed a successful airway management approach in this complicated case of critical airway compression secondary to a rare rhabdomyosarcoma, complicated by tracheal stent migration. Besides presenting our thoughts and considerations, we support exploring other possible approaches of this specific clinical problem.Keywords: airway management, rhabdomyosarcoma, stent displacement, tracheal stenosis
Procedia PDF Downloads 1032 Magnetic Single-Walled Carbon Nanotubes (SWCNTs) as Novel Theranostic Nanocarriers: Enhanced Targeting and Noninvasive MRI Tracking
Authors: Achraf Al Faraj, Asma Sultana Shaik, Baraa Al Sayed
Abstract:
Specific and effective targeting of drug delivery systems (DDS) to cancerous sites remains a major challenge for a better diagnostic and therapy. Recently, SWCNTs with their unique physicochemical properties and the ability to cross the cell membrane show promising in the biomedical field. The purpose of this study was first to develop a biocompatible iron oxide tagged SWCNTs as diagnostic nanoprobes to allow their noninvasive detection using MRI and their preferential targeting in a breast cancer murine model by placing an optimized flexible magnet over the tumor site. Magnetic targeting was associated to specific antibody-conjugated SWCNTs active targeting. The therapeutic efficacy of doxorubicin-conjugated SWCNTs was assessed, and the superiority of diffusion-weighted (DW-) MRI as sensitive imaging biomarker was investigated. Short Polyvinylpyrrolidone (PVP) stabilized water soluble SWCNTs were first developed, tagged with iron oxide nanoparticles and conjugated with Endoglin/CD105 monoclonal antibodies. They were then conjugated with doxorubicin drugs. SWCNTs conjugates were extensively characterized using TEM, UV-Vis spectrophotometer, dynamic light scattering (DLS) zeta potential analysis and electron spin resonance (ESR) spectroscopy. Their MR relaxivities (i.e. r1 and r2*) were measured at 4.7T and their iron content and metal impurities quantified using ICP-MS. SWCNTs biocompatibility and drug efficacy were then evaluated both in vitro and in vivo using a set of immunological assays. Luciferase enhanced bioluminescence 4T1 mouse mammary tumor cells (4T1-Luc2) were injected into the right inguinal mammary fat pad of Balb/c mice. Tumor bearing mice received either free doxorubicin (DOX) drug or SWCNTs with or without either DOX or iron oxide nanoparticles. A multi-pole 10x10mm high-energy flexible magnet was maintained over the tumor site during 2 hours post-injections and their properties and polarity were optimized to allow enhanced magnetic targeting of SWCNTs toward the primary tumor site. Tumor volume was quantified during the follow-up investigation study using a fast spin echo MRI sequence. In order to detect the homing of SWCNTs to the main tumor site, susceptibility-weighted multi-gradient echo (MGE) sequence was used to generate T2* maps. Apparent diffusion coefficient (ADC) measurements were also performed as a sensitive imaging biomarker providing early and better assessment of disease treatment. At several times post-SWCNT injection, histological analysis were performed on tumor extracts and iron-loaded SWCNT were quantified using ICP-MS in tumor sites, liver, spleen, kidneys, and lung. The optimized multi-poles magnet revealed an enhanced targeting of magnetic SWCNTs to the primary tumor site, which was found to be much higher than the active targeting achieved using antibody-conjugated SWCNTs. Iron-loading allowed their sensitive noninvasive tracking after intravenous administration using MRI. The active targeting of doxorubicin through magnetic antibody-conjugated SWCNTs nanoprobes was found to considerably decrease the primary tumor site and may have inhibited the development of metastasis in the tumor-bearing mice lung. ADC measurements in DW-MRI were found to significantly increase in a time-dependent manner after the injection of DOX-conjugated SWCNTs complexes.Keywords: single-walled carbon nanotubes, nanomedicine, magnetic resonance imaging, cancer diagnosis and therapy
Procedia PDF Downloads 3281 Highly Robust Crosslinked BIAN-based Binder to Stabilize High-Performance Silicon Anode in Lithium-Ion Secondary Battery
Authors: Agman Gupta, Rajashekar Badam, Noriyoshi Matsumi
Abstract:
Introduction: Recently, silicon has been recognized as one of the potential alternatives as anode active material in Li-ion batteries (LIBs) to replace the conventionally used graphite anodes. Silicon is abundantly present in the nature, it can alloy with lithium metal, and has a higher theoretical capacity (~4200 mAhg-1) that is approximately 10 times higher than graphite. However, because of a large volume expansion (~400%) upon repeated de-/alloying, the pulverization of Si particles causes the exfoliation of electrode laminate leading to the loss of electrical contact and adversely affecting the formation of solid-electrolyte interface (SEI).1 Functional polymers as binders have emerged as a competitive strategy to mitigate these drawbacks and failure mechanism of silicon anodes.1 A variety of aqueous/non-aqueous polymer binders like sodium carboxy-methyl cellulose (CMC-Na), styrene butadiene rubber (SBR), poly(acrylic acid), and other variants like mussel inspired binders have been investigated to overcome these drawbacks.1 However, there are only a few reports that mention the attempt of addressing all the drawbacks associated with silicon anodes effectively using a single novel functional polymer system as a binder. In this regard, here, we report a novel highly robust n-type bisiminoacenaphthenequinone (BIAN)-paraphenylene-based crosslinked polymer as a binder for Si anodes in lithium-ion batteries (Fig. 1). On its application, crosslinked-BIAN binder was evaluated to provide mechanical robustness to the large volume expansion of Si particles, maintain electrical conductivity within the electrode laminate, and facilitate in the formation of a thin SEI by restricting the extent of electrolyte decomposition on the surface of anode. The fabricated anodic half-cells were evaluated electrochemically for their rate capability, cyclability, and discharge capacity. Experimental: The polymerized BIAN (P-BIAN) copolymer was synthesized as per the procedure reported by our group.2 The synthesis of crosslinked P-BIAN: a solution of P-BIAN copolymer (1.497 g, 10 mmol) in N-methylpyrrolidone (NMP) (150 ml) was set-up to stir under reflux in nitrogen atmosphere. To this, 1,6-dibromohexane (5 mmol, 0.77 ml) was added dropwise. The resultant reaction mixture was stirred and refluxed at 150 °C for 24 hours followed by refrigeration for 3 hours at 5 °C. The product was obtained by evaporating the NMP solvent under reduced pressure and drying under vacuum at 120 °C for 12 hours. The obtained product was a black colored sticky compound. It was characterized by 1H-NMR, XPS, and FT-IR techniques. Results and Discussion: The N 1s XPS spectrum of the crosslinked BIAN polymer showed two characteristic peaks corresponding to the sp2 hybridized nitrogen (-C=N-) at 399.6 eV of the diimine backbone in the BP and quaternary nitrogen at 400.7 eV corresponding to the crosslinking of BP via dibromohexane. The DFT evaluation of the crosslinked BIAN binder showed that it has a low lying lowest unoccupied molecular orbital (LUMO) that enables it to get doped in the reducing environment and influence the formation of a thin (SEI). Therefore, due to the mechanically robust crosslinked matrices as well as its influence on the formation of a thin SEI, the crosslinked BIAN binder stabilized the Si anode-based half-cell for over 1000 cycles with a reversible capacity of ~2500 mAhg-1 and ~99% capacity retention as shown in Fig. 2. The dynamic electrochemical impedance spectroscopy (DEIS) characterization of crosslinked BIAN-based anodic half-cell confirmed that the SEI formed was thin in comparison with the conventional binder-based anodes. Acknowledgement: We are thankful to the financial support provided by JST-Mirai Program, Grant Number: JP18077239Keywords: self-healing binder, n-type binder, thin solid-electrolyte interphase (SEI), high-capacity silicon anodes, low-LUMO
Procedia PDF Downloads 167