Search results for: finite group A4
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 10552

Search results for: finite group A4

10162 An Efficient Traceability Mechanism in the Audited Cloud Data Storage

Authors: Ramya P, Lino Abraham Varghese, S. Bose

Abstract:

By cloud storage services, the data can be stored in the cloud, and can be shared across multiple users. Due to the unexpected hardware/software failures and human errors, which make the data stored in the cloud be lost or corrupted easily it affected the integrity of data in cloud. Some mechanisms have been designed to allow both data owners and public verifiers to efficiently audit cloud data integrity without retrieving the entire data from the cloud server. But public auditing on the integrity of shared data with the existing mechanisms will unavoidably reveal confidential information such as identity of the person, to public verifiers. Here a privacy-preserving mechanism is proposed to support public auditing on shared data stored in the cloud. It uses group signatures to compute verification metadata needed to audit the correctness of shared data. The identity of the signer on each block in shared data is kept confidential from public verifiers, who are easily verifying shared data integrity without retrieving the entire file. But on demand, the signer of the each block is reveal to the owner alone. Group private key is generated once by the owner in the static group, where as in the dynamic group, the group private key is change when the users revoke from the group. When the users leave from the group the already signed blocks are resigned by cloud service provider instead of owner is efficiently handled by efficient proxy re-signature scheme.

Keywords: data integrity, dynamic group, group signature, public auditing

Procedia PDF Downloads 392
10161 Human-Induced Vibration and Degree of Human Comfortability Analysis of Intersection Pedestrian Bridge

Authors: Yaowen Sheng, Jiuxian Liu

Abstract:

In order to analyze the pedestrian bridge dynamic characteristics and degree of comfortability, the finite element method and live load time history method is used to calculate the dynamic response of the bridge. The example bridge’s dynamic characteristics and degree of human comfortability need to be analyzed. The project background is a three-way intersection. The intersection has three side blocks. An intersection bridge is designed to help people cross the streets. The finite element model of the bridge is established by the Midas/Civil software, and the analysis of the model is done. The strength, stiffness, and stability checks are also completed. Apart from the static analysis of the bridge, the dynamic analysis of the bridge is also completed to avoid the problems resulted from vibrations. The results show that the pedestrian bridge has different dynamic characteristics compared to other normal bridges. The degree of human comfortability satisfies the requirements of Chinese and British specifications. The live load time history method can be used to calculate the dynamic response of the bridge.

Keywords: pedestrian bridge, steel box girder, human-induced vibration, finite element analysis, degree of human comfortability

Procedia PDF Downloads 157
10160 E-Bike FE Model Analysis: Connection Stiffness of Elements with Different DOFs

Authors: Lele Zhang, Hui Leng Choo, Alexander Konyukhov, Shuguang Li

Abstract:

Finite Element (FE) model of simplified e-bike structure was generated by main frame with two tiers, which consisted of pipe, mass, beam, and shell elements (pipe 289, beam188, shell 181, shell 281, combin14, link11, mass21). These elements would be introduced and demonstrated using mathematical formulas. Based on coupling theory, constrain equations was proposed. Exporting all the parameters obtained from theory part, the connection stiffness matrix of the whole e-bike structure between each of these elements was detected.

Keywords: coupling theory, stiffness matrix, e-bike, finite element model

Procedia PDF Downloads 375
10159 Effect of Springback Analysis on Influences of the Steel Demoulding Using FEM

Authors: Byeong-Sam Kim, Jongmin Park

Abstract:

The present work is motivated by the industrial challenge to produce complex composite shapes cost-effectively. The model used an anisotropical thermoviscoelastic is analyzed by an implemented finite element solver. The stress relaxation can be constructed by Prony series for the nonlinear thermoviscoelastic model. The calculation of process induced internal stresses relaxation during the cooling stage of the manufacturing cycle was carried out by the spring back phenomena observed from the part containing a cylindrical segment. The finite element results obtained from the present formulation are compared with experimental data, and the results show good correlations.

Keywords: thermoviscoelastic, springback phenomena, FEM analysis, thermoplastic composite structures

Procedia PDF Downloads 358
10158 Parasitic Capacitance Modeling in Pulse Transformer Using FEA

Authors: D. Habibinia, M. R. Feyzi

Abstract:

Nowadays, specialized software is vastly used to verify the performance of an electric machine prototype by evaluating a model of the system. These models mainly consist of electrical parameters such as inductances and resistances. However, when the operating frequency of the device is above one kHz, the effect of parasitic capacitances grows significantly. In this paper, a software-based procedure is introduced to model these capacitances within the electromagnetic simulation of the device. The case study is a high-frequency high-voltage pulse transformer. The Finite Element Analysis (FEA) software with coupled field analysis is used in this method.

Keywords: finite element analysis, parasitic capacitance, pulse transformer, high frequency

Procedia PDF Downloads 515
10157 Circular Raft Footings Strengthened by Stone Columns under Static Loads

Authors: R. Ziaie Moayed, B. Mohammadi-Haji

Abstract:

Stone columns have been widely employed to improve the load-settlement characteristics of soft soils. The results of two small scale displacement control loading tests on stone columns were used in order to validate numerical finite element simulations. Additionally, a series of numerical calculations of static loading have been performed on strengthened raft footing to investigate the effects of using stone columns on bearing capacity of footings. The bearing capacity of single and group of stone columns under static loading compares with unimproved ground.

Keywords: circular raft footing, numerical analysis, validation, vertically encased stone column

Procedia PDF Downloads 309
10156 A Randomized Comparative Evaluation of Efficacy of Ultrasound Guided Costoclavicular and Supraclavicular Approaches of Brachial Plexus Block for Upper Limb Surgeries

Authors: Anshul, Rajni Kalia, Sachin Kumar

Abstract:

Introduction: The costoclavicular approach, a modification to the infraclavicular approach, has been described for anesthesia for upper limb surgeries. Material And Methods: In this randomized and single-blind study, fourty patients undergoing emergency/elective upper limb surgery were allocated to two groups. Group C and S received ultrasound-guided Costoclavicular block and Supraclavicular block, respectively, with 20 ml 0.5 % ropivacaine with 8 mg dexamethasone under strict asepsis. The primary outcome assessed was the total duration of sensory and motor block in the postoperative period. Secondary outcomes were to compare the time taken to perform the procedure, block characteristics in terms of onset of motor and sensory blockade, the efficacy of analgesia with respect to the time of administration of the first rescue analgesic dose with both the blocks and note the side effects pertaining to either of the blocks. Results: The mean total duration of sensory and motor blockade was longer in group C vs. group S (p=0.002 and 0.024, respectively). The mean duration to perform a block in group S was more than in group C (p=0.012). The mean onset of sensory and motor Blockade Time in group S was more than in group C (p<0.001 and <0.001, respectively). The mean duration to perform a block in group S was more than in group C (p=0.012). Conclusion: The costoclavicular approach is better than supraclavicular in terms of rapid execution, faster onset of sensory-motor blockade, prolonged postoperative analgesia and similar PONV and safety profile.

Keywords: costoclavicular, supraclavicular, ropivacaine, dexamethasone

Procedia PDF Downloads 66
10155 Debris' Effect on Bearing Capacity of Defective Piles in Sand

Authors: A. M. Nasr, W. R. Azzam, K. E. Ebeed

Abstract:

For bored piles, careful cleaning must be used to reduce the amount of material trapped in the drilled hole; otherwise, the debris' presence might cause the soft toe effect, which would affect the axial resistance. There isn't much comprehensive research on bored piles with debris. In order to investigate the behavior of a single pile, a pile composite foundation, a two pile group, a three pile group and a four pile group investigation conducts, forty-eight numerical tests in which the debris is simulated using foam rubber.1m pile diameter and 10m length with spacing 3D and depth of foundation 1m used in this study. It is found that the existence of debris causes a reduction of bearing capacity by 64.58% and 33.23% for single pile and pile composite foundation, respectively, 23.27% and 24.24% for the number of defective piles / total number of pile =1/2 and 1 respectively for two group pile, 10.23%, 19.42% and 28.47% for the number of defective piles / total number of pile =1/3,2/3 and 1 respectively for three group pile and, this reduction increase with the increase in a number of defective piles / a total number of piles and 7.1%, 13.32%,19.02% and 26.36 for the number of defective piles / total number of pile =1/4,2/4,3/4 and 1 respectively for four group pile and decreases with an increase of number of pile duo to interaction effect.

Keywords: debris, Foundation, defective, interaction, board pile

Procedia PDF Downloads 96
10154 Central Finite Volume Methods Applied in Relativistic Magnetohydrodynamics: Applications in Disks and Jets

Authors: Raphael de Oliveira Garcia, Samuel Rocha de Oliveira

Abstract:

We have developed a new computer program in Fortran 90, in order to obtain numerical solutions of a system of Relativistic Magnetohydrodynamics partial differential equations with predetermined gravitation (GRMHD), capable of simulating the formation of relativistic jets from the accretion disk of matter up to his ejection. Initially we carried out a study on numerical methods of unidimensional Finite Volume, namely Lax-Friedrichs, Lax-Wendroff, Nessyahu-Tadmor method and Godunov methods dependent on Riemann problems, applied to equations Euler in order to verify their main features and make comparisons among those methods. It was then implemented the method of Finite Volume Centered of Nessyahu-Tadmor, a numerical schemes that has a formulation free and without dimensional separation of Riemann problem solvers, even in two or more spatial dimensions, at this point, already applied in equations GRMHD. Finally, the Nessyahu-Tadmor method was possible to obtain stable numerical solutions - without spurious oscillations or excessive dissipation - from the magnetized accretion disk process in rotation with respect to a central black hole (BH) Schwarzschild and immersed in a magnetosphere, for the ejection of matter in the form of jet over a distance of fourteen times the radius of the BH, a record in terms of astrophysical simulation of this kind. Also in our simulations, we managed to get substructures jets. A great advantage obtained was that, with the our code, we got simulate GRMHD equations in a simple personal computer.

Keywords: finite volume methods, central schemes, fortran 90, relativistic astrophysics, jet

Procedia PDF Downloads 454
10153 Optimum of Offshore Structures Lifting Padeyes Using Finite Element Method

Authors: Abdelrahim Hamadelnil

Abstract:

Padeye design and analysis plays important roles during the lifting, load out and installation of heavy structures. This paper explains the disadvantages of limiting the effective thickness of the cheek plate to 75% of the main plate thickness. In addition, a sensitivity study about the impact of the out of plane force on the padeye design is discussed. This study also explains the fabrication requirements to ensure that the designed strength is achieved. The objective of this study is to elaborate and discuss the philosophy of padeye design and to propose the suitable effective cheek plate thickness to be considered in the analysis of padeye. A finite element analysis using London University Structure Analysis System (LUSAS), is conducted and compared with the hand calculation. The benefits and advantage of using FE analysis is addressed in this paper. At the end of this paper, a guideline elaborating the philosophy of the design of the padeye is developed and the suitable effective thickness of cheek plate to be considered in the design is recommended. In addition, a comparison between the finite element result and the hand calculation using beam theory is discussed as well.

Keywords: cheek plate, effective thickness, out of plane force, Padeye

Procedia PDF Downloads 326
10152 Aeroelastic Analysis of Engine Nacelle Strake Considering Geometric Nonlinear Behavior

Authors: N. Manoj

Abstract:

The aeroelastic behavior of engine nacelle strake when subjected to unsteady aerodynamic flows is investigated in this paper. Geometric nonlinear characteristics and modal parameters of nacelle strake are studied when it is under dynamic loading condition. Here, an N-S based Finite Volume solver is coupled with Finite Element (FE) based nonlinear structural solver to investigate the nonlinear characteristics of nacelle strake over a range of dynamic pressures at various phases of flight like takeoff, climb, and cruise conditions. The combination of high fidelity models for both aerodynamics and structural dynamics is used to predict the nonlinearities of strake (chine). The methodology adopted for present aeroelastic analysis is partitioned-based time domain coupled CFD and CSD solvers and it is validated by the consideration of experimental and numerical comparison of aeroelastic data for a cropped delta wing model which has a proven record. The present strake geometry is derived from theoretical formulation. The amplitude and frequency obtained from the coupled solver at various dynamic pressures is discussed, which gives a better understanding of its impact on aerodynamic design-sizing of strake.

Keywords: aeroelasticity, finite volume, geometric nonlinearity, limit cycle oscillations, strake

Procedia PDF Downloads 284
10151 The Effect of β-Cryptoxanthin on Testicular Ischemia-Reperfusion Injury in a Rat Model: Evidence from Testicular Histology

Authors: Kianoush Mohammadnejad, Rahim Mohammadi, Ali Soleimanzadeh, Ali Shalizar Jalai, Farshid Sareafzadeh Rezaei

Abstract:

Testicular torsion and detorsion are significant clinical issues for infertile men. Torsion of the spermatic cord is an emergency condition resulting from the rotation of the testis and epididymis around the axis of the spermatic cord. A rat testis model was used to assess the effects of β-cryptoxanthin on ischemia-reperfusion injury. Twenty healthy male Wistar rats were included and randomized into four investigational groups (n = 5): Group SHAM: In this group, midline incision of the scrotum was performed, and the testicles were taken out for 2 hours with a 720-degree rotation. Group ISCHEMIA: In this group, a midline incision of the scrotum was performed, and the testicles were taken out and underwent ischemia for 2 hours with a 720-degree rotation. Group IS/REP/Oil: In this group, a midline scrotum cut was performed the testicles were taken out, and ischemia was created for 2 hours with a 720-degree rotation and at the end of ischemia 100 µL of corn oil (β-cryptoxanthin solvent) was injected intraperitoneally. Group IS/REP/CRPTXNTN 2.5: The same as group IS/REP/Oil as well as intraperitoneal administration of 100 µL of β-cryptoxanthin (2.5 µg/kg) at the end of ischemia. In all groups, the testes were returned back to the scrotum and, after 60 days, were dissected out and removed for histopathological analyses. β-cryptoxanthin at the dose of 2.5 µg/kg significantly improved histologic indices compared to other treatment groups (p<0.05). β-cryptoxanthin could be helpful in minimizing ischemia-reperfusion injury in testicular tissue exposed to ischemia.

Keywords: beta-cryptoxanthin, testis, Ischemia-reperfusion, Intraperitoneal

Procedia PDF Downloads 18
10150 Whole Body Cooling Hypothermia Treatment Modelling Using a Finite Element Thermoregulation Model

Authors: Ana Beatriz C. G. Silva, Luiz Carlos Wrobel, Fernando Luiz B. Ribeiro

Abstract:

This paper presents a thermoregulation model using the finite element method to perform numerical analyses of brain cooling procedures as a contribution to the investigation on the use of therapeutic hypothermia after ischemia in adults. The use of computational methods can aid clinicians to observe body temperature using different cooling methods without the need of invasive techniques, and can thus be a valuable tool to assist clinical trials simulating different cooling options that can be used for treatment. In this work, we developed a FEM package applied to the solution of the continuum bioheat Pennes equation. Blood temperature changes were considered using a blood pool approach and a lumped analysis for intravascular catheter method of blood cooling. Some analyses are performed using a three-dimensional mesh based on a complex geometry obtained from computed tomography medical images, considering a cooling blanket and a intravascular catheter. A comparison is made between the results obtained and the effects of each case in brain temperature reduction in a required time, maintenance of body temperature at moderate hypothermia levels and gradual rewarming.

Keywords: brain cooling, finite element method, hypothermia treatment, thermoregulation

Procedia PDF Downloads 311
10149 Improving Taint Analysis of Android Applications Using Finite State Machines

Authors: Assad Maalouf, Lunjin Lu, James Lynott

Abstract:

We present a taint analysis that can automatically detect when string operations result in a string that is free of taints, where all the tainted patterns have been removed. This is an improvement on the conservative behavior of previous taint analyzers, where a string operation on a tainted string always leads to a tainted string unless the operation is manually marked as a sanitizer. The taint analysis is built on top of a string analysis that uses finite state automata to approximate the sets of values that string variables can take during the execution of a program. The proposed approach has been implemented as an extension of FlowDroid and experimental results show that the resulting taint analyzer is much more precise than the original FlowDroid.

Keywords: android, static analysis, string analysis, taint analysis

Procedia PDF Downloads 180
10148 A Nonlinear Parabolic Partial Differential Equation Model for Image Enhancement

Authors: Tudor Barbu

Abstract:

We present a robust nonlinear parabolic partial differential equation (PDE)-based denoising scheme in this article. Our approach is based on a second-order anisotropic diffusion model that is described first. Then, a consistent and explicit numerical approximation algorithm is constructed for this continuous model by using the finite-difference method. Finally, our restoration experiments and method comparison, which prove the effectiveness of this proposed technique, are discussed in this paper.

Keywords: anisotropic diffusion, finite differences, image denoising and restoration, nonlinear PDE model, anisotropic diffusion, numerical approximation schemes

Procedia PDF Downloads 312
10147 Comparison of Two Strategies in Thoracoscopic Ablation of Atrial Fibrillation

Authors: Alexander Zotov, Ilkin Osmanov, Emil Sakharov, Oleg Shelest, Aleksander Troitskiy, Robert Khabazov

Abstract:

Objective: Thoracoscopic surgical ablation of atrial fibrillation (AF) includes two technologies in performing of operation. 1st strategy used is the AtriCure device (bipolar, nonirrigated, non clamping), 2nd strategy is- the Medtronic device (bipolar, irrigated, clamping). The study presents a comparative analysis of clinical outcomes of two strategies in thoracoscopic ablation of AF using AtriCure vs. Medtronic devices. Methods: In 2 center study, 123 patients underwent thoracoscopic ablation of AF for the period from 2016 to 2020. Patients were divided into two groups. The first group is represented by patients who applied the AtriCure device (N=63), and the second group is - the Medtronic device (N=60), respectively. Patients were comparable in age, gender, and initial severity of the condition. Among the patients, in group 1 were 65% males with a median age of 57 years, while in group 2 – 75% and 60 years, respectively. Group 1 included patients with paroxysmal form -14,3%, persistent form - 68,3%, long-standing persistent form – 17,5%, group 2 – 13,3%, 13,3% and 73,3% respectively. Median ejection fraction and indexed left atrial volume amounted in group 1 – 63% and 40,6 ml/m2, in group 2 - 56% and 40,5 ml/m2. In addition, group 1 consisted of 39,7% patients with chronic heart failure (NYHA Class II) and 4,8% with chronic heart failure (NYHA Class III), when in group 2 – 45% and 6,7%, respectively. Follow-up consisted of laboratory tests, chest Х-ray, ECG, 24-hour Holter monitor, and cardiopulmonary exercise test. Duration of freedom from AF, distant mortality rate, and prevalence of cerebrovascular events were compared between the two groups. Results: Exit block was achieved in all patients. According to the Clavien-Dindo classification of surgical complications fraction of adverse events was 14,3% and 16,7% (1st group and 2nd group, respectively). Mean follow-up period in the 1st group was 50,4 (31,8; 64,8) months, in 2nd group - 30,5 (14,1; 37,5) months (P=0,0001). In group 1 - total freedom of AF was in 73,3% of patients, among which 25% had additional antiarrhythmic drugs (AADs) therapy or catheter ablation (CA), in group 2 – 90% and 18,3%, respectively (for total freedom of AF P<0,02). At follow-up, the distant mortality rate in the 1st group was – 4,8%, and in the 2nd – no fatal events. Prevalence of cerebrovascular events was higher in the 1st group than in the 2nd (6,7% vs. 1,7% respectively). Conclusions: Despite the relatively shorter follow-up of the 2nd group in the study, applying the strategy using the Medtronic device showed quite encouraging results. Further research is needed to evaluate the effectiveness of this strategy in the long-term period.

Keywords: atrial fibrillation, clamping, ablation, thoracoscopic surgery

Procedia PDF Downloads 110
10146 Static Modeling of the Delamination of a Composite Material Laminate in Mode II

Authors: Y. Madani, H. Achache, B. Boutabout

Abstract:

The purpose of this paper is to analyze numerically by the three-dimensional finite element method, using ABAQUS calculation code, the mechanical behavior of a unidirectional and multidirectional delaminated stratified composite under mechanical loading in Mode II. This study consists of the determination of the energy release rate G in mode II as well as the distribution of equivalent von Mises stresses along the damaged zone by varying several parameters such as the applied load and the delamination length. It allowed us to deduce that the high energy release rate favors delamination at the free edges of a stratified plate subjected to bending.

Keywords: delamination, energy release rate, finite element method, stratified composite

Procedia PDF Downloads 176
10145 Finite Element Method for Solving the Generalized RLW Equation

Authors: Abdel-Maksoud Abdel-Kader Soliman

Abstract:

The General Regularized Long Wave (GRLW) equation is solved numerically by giving a new algorithm based on collocation method using quartic B-splines at the mid-knot points as element shape. Also, we use the Fourth Runge-Kutta method for solving the system of first order ordinary differential equations instead of finite difference method. Our test problems, including the migration and interaction of solitary waves, are used to validate the algorithm which is found to be accurate and efficient. The three invariants of the motion are evaluated to determine the conservation properties of the algorithm.

Keywords: generalized RLW equation, solitons, quartic b-spline, nonlinear partial differential equations, difference equations

Procedia PDF Downloads 489
10144 Randomized Controlled Trial of Group Cognitive Behavioral Therapy for Depressive Symptoms among Menopausal Chinese Women

Authors: Jing Ding

Abstract:

The present study will propose a Randomized Controlled Trial (RCT) that will assess the efficacy of group Cognitive Behavioral Therapy (CBT) in treating depressive symptoms among menopausal women in China. Considering the high prevalence of menopausal symptoms and depressive disorders among this population, the present study is intended to explore whether group CBT can provide relief for these psychological disturbances commonly linked with hot flashes and night sweats during menopause. Thus, participants will be recruited through gynecologic and psychological outpatient clinics in Beijing, China, and then randomly assigned to either the CBT intervention group or the waitlist control group. The primary outcome measures for major depression will include the PHQ-9, while for menopausal symptoms, the main outcome measure will be the KMI. Secondary measures will include the assessment of sleep quality, quality of life, and general well-being. The current study offers evidence-based intervention for non-pharmacological menopausal symptoms in women and underlines the benefits that group CBT can have, both at a mental health level and for physical symptoms during menopause. This study could set the stage for the wider clinical practice of CBT with this demographic.

Keywords: group CBT, depression, women's mental health, menopause

Procedia PDF Downloads 15
10143 Comparison of the Glidescope Visualization and Neck Flexion with Lateral Neck Pressure Nasogastric Tube Insertion Techniques in Anaesthetized Patients: A Prospective Randomized Clinical Study

Authors: Pitchaporn Purngpiputtrakul, Suttasinee Petsakul, Sunisa Chatmongkolchart

Abstract:

Nasogastric tube (NGT) insertion in anaesthetized and intubated patients can be challenging even for experienced anesthesiologists. Various techniques have been proposed to facilitate NGT insertion in these patients. This study aimed to compare the success rate and time required for NGT insertion between the GlideScope visualization and neck flexion with lateral neck pressure techniques. This randomized clinical trial was performed at a teaching hospital on 86 adult patients undergoing abdominal surgery under relaxant general anaesthesia who required intraoperative NGT insertion. The patients were randomized into two groups, the GlideScope group (group G) and the neck flexion with lateral neck pressure group (group F). The success rate of first and second attempts, duration of insertion, and complications were recorded. The total success rate was 79.1% in Group G compared with 76.7% in Group F (P=1) The median time required for NGT insertion was significantly longer in Group G, for both first and second attempts (97 vs 42 seconds P<0.001) and (70 vs 48.5 seconds P=0.015), respectively. Complications were reported in 23 patients (53.5%) in group G and 13 patients (30.2%) in group F. Bleeding and kinking were the most common complications in both techniques. Using GlideScope visualization to facilitate NGT insertion was comparable to neck flexion with lateral neck pressure technique in degree of success rate of insertion, while neck flexion with lateral neck pressure technique had fewer complications and was less time-consuming.

Keywords: anaesthesia, nasogastric tube, GlideScope, intubation

Procedia PDF Downloads 164
10142 Industrial Management of Highland Community: The Hmong Ethnic Group Hill Tribe, Phetchabun Province

Authors: Kusuma Palaprom

Abstract:

The aims of this research are: 1) to study Hmong ethnic group hill tribe’s way of life and community industrial management and 2) to bring the industrial management into the community. This is a Participatory Action Research (PAR) using qualitative and quantitative data. The findings are: 1) Way of living and learning from nature of Hmong ethnic group hill tribe bases on their cultural relic belief. Hmong‘s way of life or occupation is traditional agriculture which cannot be business because they cannot adopt the industrial management to the community economic innovation base on local wisdom. 2) Quality of life development using local wisdom cost is not worth. Hmong ethnic group hill tribe are lack of modern knowledge-managerial aspect and the application of local wisdom cost and 3) the government supports for Hmong’s developing of life quality are limited. Solving problem guidelines are: 1) to create awareness of ethnic group wisdom-industrial conservation. 2) Government policy need to give an opportunity and motivate ethnic group community to do the cultural-industrial conservation with industrial management process and local wisdom cost. In order to, improve the sustainability of quality of life.

Keywords: industrial management, highland community, community empowerment ethnic group

Procedia PDF Downloads 570
10141 Parametric Study for Optimal Design of Hybrid Bridge Joint

Authors: Bongsik Park, Jae Hyun Park, Jae-Yeol Cho

Abstract:

Mixed structure, which is a kind of hybrid system, is incorporating steel beam and prestressed concrete beam. Hybrid bridge adopting mixed structure have some merits. Main span length can be made longer by using steel as main span material. In case of cable-stayed bridge having asymmetric span length, negative reaction at side span can be restrained without extra restraining devices by using weight difference between main span material and side span material. However angle of refraction might happen because of rigidity difference between materials and stress concentration also might happen because of abnormal loading transmission at joint in the hybrid bridge. Therefore the joint might be a weak point of the structural system and it needs to pay attention to design of the joint. However, design codes and standards about the joint in the hybrid-bridge have not been established so the joint designs in most of construction cases have been very conservative or followed previous design without extra verification. In this study parametric study using finite element analysis for optimal design of hybrid bridge joint is conducted. Before parametric study, finite element analysis was conducted based on previous experimental data and it is verified that analysis result approximated experimental data. Based on the finite element analysis results, parametric study was conducted. The parameters were selected as those have influences on joint behavior. Based on the parametric study results, optimal design of hybrid bridge joint has been determined.

Keywords: parametric study, optimal design, hybrid bridge, finite element analysis

Procedia PDF Downloads 425
10140 Optimizing Mechanical Behavior of Middle Ear Prosthesis Using Finite Element Method with Material Degradation Functionally Graded Materials in Three Functions

Authors: Khatir Omar, Fekih Sidi Mohamed, Sahli Abderahmene, Benkhettou Abdelkader, Boudjemaa Ismail

Abstract:

Advancements in technology have revolutionized healthcare, with notable impacts on auditory health. This study introduces an approach aimed at optimizing materials for middle ear prostheses to enhance auditory performance. We have developed a finite element (FE) model of the ear incorporating a pure titanium TORP prosthesis, validated against experimental data. Subsequently, we applied the Functionally Graded Materials (FGM) methodology, utilizing linear, exponential, and logarithmic degradation functions to modify prosthesis materials. Biocompatible materials suitable for auditory prostheses, including Stainless Steel, titanium, and Hydroxyapatite, were investigated. The findings indicate that combinations such as Stainless Steel with titanium and Hydroxyapatite offer improved outcomes compared to pure titanium and Hydroxyapatite ceramic in terms of both displacement and stress. Additionally, personalized prostheses tailored to individual patient needs are feasible, underscoring the potential for further advancements in auditory healthcare.

Keywords: middle ear, prosthesis, ossicles, FGM, vibration analysis, finite-element method

Procedia PDF Downloads 84
10139 Settlement of Group of Stone Columns

Authors: Adel Hanna, Tahar Ayadat, Mohammad Etezad, Cyrille Cros

Abstract:

A number of theoretical methods have been developed over the years to calculate the amount settlement of the soil reinforced with group of stone columns. The results deduced from these methods sometimes show large disagreement with the experimental observations. The reason of this divergence might be due to the fact that many of the previous methods assumed the deform shape of the columns which is different with the actual case. A new method to calculate settlement of the ground reinforced with group of stone columns is presented in this paper which overcomes the restrictions made by previous theories. This method is based on results deduced from numerical modeling. Results obtained from the model are validated.

Keywords: stone columns, group, soft soil, settlement, prediction

Procedia PDF Downloads 505
10138 Effectiveness of Clinical Practice Guidelines for Jellyfish Stings Treatment at the Emergency Room of Songkhla Hospital Thailand

Authors: Prataksitorn Chonlakan, Tiparat Wongsilarat

Abstract:

The traditional clinical practice guideline used at the emergency room at Songkhla Hospital in caring for patients who come in contact with jellyfish venom took a long time for the pain to reduce to the level that patients can cope with. To investigate the effectiveness of clinical practice guidelines by comparing the effectiveness of a newly developed clinical practice guideline with the traditional clinical practice guideline in the following aspects: 1) pain reduction, 2) length of pain, 3) the rate of patient’s re-visit, 4) the rate of severe complications such as anaphylactic shock, and cardiac arrest, and death, and 5) patient satisfaction. This study employed a quasi-experimental research design. Thirty subjects were selected with purposive sampling from jellyfish-sting patients who came for treatment at the Emergency Room of Songkhla Hospital. The subjects were divided using random assignment into two groups of 15 each: an experimental group, and the control group. The control group was treated using the traditional clinical practice guideline consisting of rinsing the affected area with 0.9% normal saline, using a cloth soaked with vinegar to press against the affected area, and controlling pain using tramadol or diclofenac intramuscular injection. The data were analyzed using descriptive statistics and paired t-test at the significance level p < 0.05. The results of the study revealed the following. The pain level in the experimental group was significantly lower than that of the control group (the average pain score of the experimental group was 3.46 while that of the control group was 6.33) (p < 0.05).The length of pain in the experimental group was significantly lower than that of the control group (the average length of pain in the experimental group was 48.67 minutes while that of the control group was 105.35 minutes) (p < 0.05). The rate of re-visit within 12 hours in the experimental group was significantly lower than that of the control group (the rate of re-visit within 12 hours of the experimental group was 0.07 while that of the control group was 0.00) (p < 0.05).No severe complications such as anaphylactic shock, and cardiac arrest were found in the two groups of subjects.The rate of satisfaction among the subjects in the experimental group was significantly higher than that of the control group (the rate of satisfaction among the subjects of the experimental group was 90.00 percent while that among the control group was 66.33 percent) (p < 0.05). The newly develop clinical practice guideline could reduce pain and increase satisfaction among jellyfish-sting patients better than the traditional clinical practice guideline.

Keywords: effectiveness, clinical practice guideline, jellyfish-sting patients, cardiac arrest

Procedia PDF Downloads 351
10137 Analysis of Lift Force in Hydrodynamic Transport of a Finite Sized Particle in Inertial Microfluidics with a Rectangular Microchannel

Authors: Xinghui Wu, Chun Yang

Abstract:

Inertial microfluidics is a competitive fluidic method with applications in separation of particles, cells and bacteria. In contrast to traditional microfluidic devices with low Reynolds number, inertial microfluidics works in the intermediate Re number range which brings about several intriguing inertial effects on particle separation/focusing to meet the throughput requirement in the real-world. Geometric modifications to make channels become irregular shapes can leverage fluid inertia to create complex secondary flow for adjusting the particle equilibrium positions and thus enhance the separation resolution and throughput. Although inertial microfluidics has been extensively studied by experiments, our current understanding of its mechanisms is poor, making it extremely difficult to build rational-design guidelines for the particle focusing locations, especially for irregularly shaped microfluidic channels. Inertial particle microfluidics in irregularly shaped channels were investigated in our group. There are several fundamental issues that require us to address. One of them is about the balance between the inertial lift forces and the secondary drag forces. Also, it is critical to quantitatively describe the dependence of the life forces on particle-particle interactions in irregularly shaped channels, such as a rectangular one. To provide physical insights into the inertial microfluidics in channels of irregular shapes, in this work the immersed boundary-lattice Boltzmann method (IB-LBM) was introduced and validated to explore the transport characteristics and the underlying mechanisms of an inertial focusing single particle in a rectangular microchannel. The transport dynamics of a finitesized particle were investigated over wide ranges of Reynolds number (20 < Re < 500) and particle size. The results show that the inner equilibrium positions are more difficult to occur in the rectangular channel, which can be explained by the secondary flow caused by the presence of a finite-sized particle. Furthermore, force decoupling analysis was utilized to study the effect of each type of lift force on the inertia migration, and a theoretical model for the lateral lift force of a finite-sized particle in the rectangular channel was established. Such theoretical model can be used to provide theoretical guidance for the design and operation of inertial microfluidics.

Keywords: inertial microfluidics, particle focuse, life force, IB-LBM

Procedia PDF Downloads 71
10136 Lamb Waves in Plates Subjected to Uniaxial Stresses

Authors: Munawwar Mohabuth, Andrei Kotousov, Ching-Tai Ng

Abstract:

On the basis of the finite deformation theory, the effect of homogeneous stress on the propagation of Lamb waves in an initially isotropic hyperelastic plate is analysed. The equations governing the propagation of small amplitude waves in the prestressed plate are derived using the theory of small deformations superimposed on large deformations. By enforcing traction free boundary conditions at the upper and lower surfaces of the plate, acoustoelastic dispersion equations for Lamb wave propagation are obtained, which are solved numerically. Results are given for an aluminum plate subjected to a range of applied stresses.

Keywords: acoustoelasticity, dispersion, finite deformation, lamb waves

Procedia PDF Downloads 467
10135 Rutin C Improve Osseointegration of Dental Implant and Healing of Soft Tissue

Authors: Noha Mohammed Ismael Awad Eladal, Aala Shoukry Emara

Abstract:

Background: Wound healing after dental implant surgery is critical to the procedure's success. The aim of this study was to explore the effects of rutin+vitamin C supplementation in wound healing following the placement of dental implants. Methodology: There were 20 participants in this randomized controlled clinical trial who needed dental implants to replace missing teeth. Patients were divided into two groups, and group A received dental implants. Group B received dental implants with vitamin C administration. Follow-up appointments were performed on day 3, day 7, and day 14 post-surgery, during which soft tissue healing and pain response scores were evaluated using the visual analog scale. Postoperative digital panoramas were taken immediately after surgery, 3 months and 6 months postoperatively. Changes in bone density along with the bone-implant interface at the mesial, distal and apical sides were assessed using the digora software. Results: An independent t-test was used to compare the means of variables between the two groups. At the same time, repeated measures were employed to compare the means of variables between two groups. ANOVA was used to compare bone density for the same group at different dates. Significant increased differences were observed at the mesial, distal and apical sides Surrounding the implants of both groups per time. However, the rate of increase was significantly higher in group B The mean difference at the mesial side after 6 months was 21.99 ± 5.48 in the group B and 14.21 ± 4.95 in group A, while it read 21.74 ± 3.56 in the group B and 10.78 ± 3.90 in group A at the distal side and was 18.90 ± 5.91 in the group B and 10.39 ± 3.49 group A at the apical side. Significance was recorded at P = 0.004, P = 0.0001, and 0.001 at the mesial, distal and apical sides respectively. The mean pain score and wound healing were significantly higher in group A as compared to group B, respectively. Conclusion: The rutin c + vitamin c group significantly promoted bone healing and speeded up the osseointegration process and improved soft tissue healing.

Keywords: osseointegration, soft tissue, rutin c, dental implant

Procedia PDF Downloads 149
10134 Experimental and Numerical Investigation on Deformation Behaviour of Single Crystal Copper

Authors: Suman Paik, P. V. Durgaprasad, Bijan K. Dutta

Abstract:

A study combining experimental and numerical investigation on the deformation behaviour of single crystals of copper is presented in this paper. Cylindrical samples were cut in specific orientations from high purity copper single crystal and subjected to uniaxial compression loading at quasi-static strain rate. The stress-strain curves along two different crystallographic orientations were then extracted. In order to study and compare the deformation responses, a single crystal plasticity model incorporating non-Schmid effects was developed assuming cross-slip plays an important role in orientation of the material. By making use of crystal plasticity finite element method, the model was applied to investigate the orientation dependence of the stress-strain behaviour of two crystallographic orientations. Finally, details of slip activities of deformed crystals were investigated by linking the orientation of slip lines with the theoretical traces of possible crystallographic planes. The experimentally determined active slip modes were matched with those determined by simulations.

Keywords: crystal plasticity, modelling, non-Schmid effects, finite elements, finite strain

Procedia PDF Downloads 213
10133 Finite Element Analysis of Thermally-Induced Bistable Plate Using Four Plate Elements

Authors: Jixiao Tao, Xiaoqiao He

Abstract:

The present study deals with the finite element (FE) analysis of thermally-induced bistable plate using various plate elements. The quadrilateral plate elements include the 4-node conforming plate element based on the classical laminate plate theory (CLPT), the 4-node and 9-node Mindlin plate element based on the first-order shear deformation laminated plate theory (FSDT), and a displacement-based 4-node quadrilateral element (RDKQ-NL20). Using the von-Karman’s large deflection theory and the total Lagrangian (TL) approach, the nonlinear FE governing equations for plate under thermal load are derived. Convergence analysis for four elements is first conducted. These elements are then used to predict the stable shapes of thermally-induced bistable plate. Numerical test shows that the plate element based on FSDT, namely the 4-node and 9-node Mindlin, and the RDKQ-NL20 plate element can predict two stable cylindrical shapes while the 4-node conforming plate predicts a saddles shape. Comparing the simulation results with ABAQUS, the RDKQ-NL20 element shows the best accuracy among all the elements.

Keywords: Bistable, finite element method, geometrical nonlinearity, quadrilateral plate elements

Procedia PDF Downloads 220