Search results for: Doppler ultrasound
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 565

Search results for: Doppler ultrasound

295 Case Report of Left Atrial Myxoma Diagnosed by Bedside Echocardiography

Authors: Anthony S. Machi, Joseph Minardi

Abstract:

We present a case report of left atrial myxoma diagnosed by bedside transesophageal (TEE) ultrasound. Left atrial myxoma is the most common benign cardiac tumor and can obstruct blood flow and cause valvular insufficiency. Common symptoms consist of dyspnea, pulmonary edema and other features of left heart failure in addition to thrombus release in the form of tumor fragments. The availability of bedside ultrasound equipment is essential for the quick diagnosis and treatment of various emergency conditions including cardiac neoplasms. A 48-year-old Caucasian female with a four-year history of an untreated renal mass and anemia presented to the ED with two months of sharp, intermittent, bilateral flank pain radiating into the abdomen. She also reported intermittent vomiting and constipation along with generalized body aches, night sweats, and 100-pound weight loss over last year. She had a CT in 2013 showing a 3 cm left renal mass and a second CT in April 2016 showing a 3.8 cm left renal mass along with a past medical history of diverticulosis, chronic bronchitis, dyspnea on exertion, uncontrolled hypertension, and hyperlipidemia. Her maternal family history is positive for breast cancer, hypertension, and Type II Diabetes. Her paternal family history is positive for stroke. She was a current everyday smoker with an 11 pack/year history. Alcohol and drug use were denied. Physical exam was notable for a Grade II/IV systolic murmur at the right upper sternal border, dyspnea on exertion without angina, and a tender left lower quadrant. Her vitals and labs were notable for a blood pressure of 144/96, heart rate of 96 beats per minute, pulse oximetry of 96%, hemoglobin of 7.6 g/dL, hypokalemia, hypochloremia, and multiple other abnormalities. Physicians ordered a CT to evaluate her flank pain which revealed a 7.2 x 8.9 x 10.5 cm mixed cystic/solid mass in the lower pole of the left kidney and a filling defect in the left atrium. Bedside TEE was ordered to follow up on the filling defect. TEE reported an ejection fraction of 60-65% and visualized a mobile 6 x 3 cm mass in the left atrium attached to the interatrial septum extending into the mitral valve. Cardiothoracic Surgery and Urology were consulted and confirmed a diagnosis of left atrial myxoma and clear cell renal cell carcinoma. The patient returned a week later due to worsening nausea and vomiting and underwent emergent nephrectomy, lymph node dissection, and colostomy due to a necrotic colon. Her condition declined over the next four months due to lung and brain metastases, infections, and other complications until she passed away.

Keywords: bedside ultrasound, echocardiography, emergency medicine, left atrial myxoma

Procedia PDF Downloads 331
294 Adapting an Accurate Reverse-time Migration Method to USCT Imaging

Authors: Brayden Mi

Abstract:

Reverse time migration has been widely used in the Petroleum exploration industry to reveal subsurface images and to detect rock and fluid properties since the early 1980s. The seismic technology involves the construction of a velocity model through interpretive model construction, seismic tomography, or full waveform inversion, and the application of the reverse-time propagation of acquired seismic data and the original wavelet used in the acquisition. The methodology has matured from 2D, simple media to present-day to handle full 3D imaging challenges in extremely complex geological conditions. Conventional Ultrasound computed tomography (USCT) utilize travel-time-inversion to reconstruct the velocity structure of an organ. With the velocity structure, USCT data can be migrated with the “bend-ray” method, also known as migration. Its seismic application counterpart is called Kirchhoff depth migration, in which the source of reflective energy is traced by ray-tracing and summed to produce a subsurface image. It is well known that ray-tracing-based migration has severe limitations in strongly heterogeneous media and irregular acquisition geometries. Reverse time migration (RTM), on the other hand, fully accounts for the wave phenomena, including multiple arrives and turning rays due to complex velocity structure. It has the capability to fully reconstruct the image detectable in its acquisition aperture. The RTM algorithms typically require a rather accurate velocity model and demand high computing powers, and may not be applicable to real-time imaging as normally required in day-to-day medical operations. However, with the improvement of computing technology, such a computational bottleneck may not present a challenge in the near future. The present-day (RTM) algorithms are typically implemented from a flat datum for the seismic industry. It can be modified to accommodate any acquisition geometry and aperture, as long as sufficient illumination is provided. Such flexibility of RTM can be conveniently implemented for the application in USCT imaging if the spatial coordinates of the transmitters and receivers are known and enough data is collected to provide full illumination. This paper proposes an implementation of a full 3D RTM algorithm for USCT imaging to produce an accurate 3D acoustic image based on the Phase-shift-plus-interpolation (PSPI) method for wavefield extrapolation. In this method, each acquired data set (shot) is propagated back in time, and a known ultrasound wavelet is propagated forward in time, with PSPI wavefield extrapolation and a piece-wise constant velocity model of the organ (breast). The imaging condition is then applied to produce a partial image. Although each image is subject to the limitation of its own illumination aperture, the stack of multiple partial images will produce a full image of the organ, with a much-reduced noise level if compared with individual partial images.

Keywords: illumination, reverse time migration (RTM), ultrasound computed tomography (USCT), wavefield extrapolation

Procedia PDF Downloads 74
293 Coherent Ku-Band Radar for Monitoring Ocean Waves

Authors: Richard Mitchell, Robert Mitchell, Thai Duong, Kyungbin Bae, Daegon Kim, Youngsub Lee, Inho Kim, Inho Park, Hyungseok Lee

Abstract:

Although X-band radar is commonly used to measure the properties of ocean waves, the use of a higher frequency has several advantages, such as increased backscatter coefficient, better Doppler sensitivity, lower power, and a smaller package. A low-power Ku-band radar system was developed to demonstrate these advantages. It is fully coherent, and it interleaves short and long pulses to achieve a transmit duty ratio of 25%, which makes the best use of solid-state amplifiers. The range scales are 2 km, 4 km, and 8 km. The minimum range is 100 m, 200 m, and 400 m for the three range scales, and the range resolution is 4 m, 8 m, and 16 m for the three range scales. Measurements of the significant wave height, wavelength, wave period, and wave direction have been made using traditional 3D-FFT methods. Radar and ultrasonic sensor results collected over an extended period of time at a coastal site in South Korea are presented.

Keywords: measurement of ocean wave parameters, Ku-band radar, coherent radar, compact radar

Procedia PDF Downloads 169
292 Autophagy Suppresses Bladder Tumor Formation in a Mouse Orthotopic Bladder Tumor Formation Model

Authors: Wan-Ting Kuo, Yi-Wen Liu, Hsiao-Sheng Liu

Abstract:

Annual incidence of bladder cancer increases in the world and occurs frequently in the male. Most common type is transitional cell carcinoma (TCC) which is treated by transurethral resection followed by intravesical administration of agents. In clinical treatment of bladder cancer, chemotherapeutic drugs-induced apoptosis is always used in patients. However, cancers usually develop resistance to chemotherapeutic drugs and often lead to aggressive tumors with worse clinical outcomes. Approximate 70% TCC recurs and 30% recurrent tumors progress to high-grade invasive tumors, indicating that new therapeutic agents are urgently needed to improve the successful rate of overall treatment. Nonapoptotic program cell death may assist to overcome worse clinical outcomes. Autophagy which is one of the nonapoptotic pathways provides another option for bladder cancer patients. Autophagy is reported as a potent anticancer therapy in some cancers. First of all, we established a mouse orthotopic bladder tumor formation model in order to create a similar tumor microenvironment. IVIS system and micro-ultrasound were utilized to noninvasively monitor tumor formation. In addition, we carried out intravesical treatment in our animal model to be consistent with human clinical treatment. In our study, we carried out intravesical instillation of the autophagy inducer in mouse orthotopic bladder tumor to observe tumor formation by noninvasive IVIS system and micro-ultrasound. Our results showed that bladder tumor formation is suppressed by the autophagy inducer, and there are no significant side effects in the physiology of mice. Furthermore, the autophagy inducer upregulated autophagy in bladder tissues of the treated mice was confirmed by Western blot, immunohistochemistry, and immunofluorescence. In conclusion, we reveal that a novel autophagy inducer with low side effects suppresses bladder tumor formation in our mouse orthotopic bladder tumor model, and it provides another therapeutic approach in bladder cancer patients.

Keywords: bladder cancer, transitional cell carcinoma, orthotopic bladder tumor formation model, autophagy

Procedia PDF Downloads 177
291 Investigation of Al/Si, Au/Si and Au/GaAs Interfaces by Positron Annihilation Spectroscopy

Authors: Abdulnasser S. Saleh

Abstract:

The importance of metal-semiconductor interfaces comes from the fact that most electronic devices are interconnected using metallic wiring that forms metal–semiconductor contacts. The properties of these contacts can vary considerably depending on the nature of the interface with the semiconductor. Variable-energy positron annihilation spectroscopy has been applied to study interfaces in Al/Si, Au/Si, and Au/GaAs structures. A computational modeling by ROYPROF program is used to analyze Doppler broadening results in order to determine kinds of regions that positrons are likely to sample. In all fittings, the interfaces are found 1 nm thick and act as an absorbing sink for positrons diffusing towards them and may be regarded as highly defective. Internal electric fields were found to influence positrons diffusing to the interfaces and unable to force them cross to the other side. The materials positron affinities are considered in understanding such motion. The results of these theoretical fittings have clearly demonstrated the sensitivity of interfaces in any fitting attempts of analyzing positron spectroscopy data and gave valuable information about metal-semiconductor interfaces.

Keywords: interfaces, semiconductor, positron, defects

Procedia PDF Downloads 261
290 Sonication as a Versatile Tool for Photocatalysts’ Synthesis and Intensification of Flow Photocatalytic Processes Within the Lignocellulose Valorization Concept

Authors: J. C. Colmenares, M. Paszkiewicz-Gawron, D. Lomot, S. R. Pradhan, A. Qayyum

Abstract:

This work is a report of recent selected experiments of photocatalysis intensification using flow microphotoreactors (fabricated by an ultrasound-based technique) for photocatalytic selective oxidation of benzyl alcohol (BnOH) to benzaldehyde (PhCHO) (in the frame of the concept of lignin valorization), and the proof of concept of intensifying a flow selective photocatalytic oxidation process by acoustic cavitation. The synthesized photocatalysts were characterized by using different techniques such as UV-Vis diffuse reflectance spectroscopy, X-ray diffraction, nitrogen sorption, thermal gravimetric analysis, and transmission electron microscopy. More specifically, the work will be on: a Design and development of metal-containing TiO₂ coated microflow reactor for photocatalytic partial oxidation of benzyl alcohol: The current work introduces an efficient ultrasound-based metal (Fe, Cu, Co)-containing TiO₂ deposition on the inner walls of a perfluoroalkoxy alkanes (PFA) microtube under mild conditions. The experiments were carried out using commercial TiO₂ and sol-gel synthesized TiO₂. The rough surface formed during sonication is the site for the deposition of these nanoparticles in the inner walls of the microtube. The photocatalytic activities of these semiconductor coated fluoropolymer based microreactors were evaluated for the selective oxidation of BnOH to PhCHO in the liquid flow phase. The analysis of the results showed that various features/parameters are crucial, and by tuning them, it is feasible to improve the conversion of benzyl alcohol and benzaldehyde selectivity. Among all the metal-containing TiO₂ samples, the 0.5 at% Fe/TiO₂ (both, iron and titanium, as cheap, safe, and abundant metals) photocatalyst exhibited the highest BnOH conversion under visible light (515 nm) in a microflow system. This could be explained by the higher crystallite size, high porosity, and flake-like morphology. b. Designing/fabricating photocatalysts by a sonochemical approach and testing them in the appropriate flow sonophotoreactor towards sustainable selective oxidation of key organic model compounds of lignin: Ultrasonication (US)-assitedprecipitaion and US-assitedhydrosolvothermal methods were used for the synthesis of metal-oxide-based and metal-free-carbon-based photocatalysts, respectively. Additionally, we report selected experiments of intensification of a flow photocatalytic selective oxidation through the use of ultrasonic waves. The effort of our research is focused on the utilization of flow sonophotocatalysis for the selective transformation of lignin-based model molecules by nanostructured metal oxides (e.g., TiO₂), and metal-free carbocatalysts. A plethora of parameters that affects the acoustic cavitation phenomena, and as a result the potential of sonication were investigated (e.g. ultrasound frequency and power). Various important photocatalytic parameters such as the wavelength and intensity of the irradiated light, photocatalyst loading, type of solvent, mixture of solvents, and solution pH were also optimized.

Keywords: heterogeneous photo-catalysis, metal-free carbonaceous materials, selective redox flow sonophotocatalysis, titanium dioxide

Procedia PDF Downloads 101
289 Experimental and Computational Investigations of Baffle Position Effects on ‎the Performance of Oil and Water Separator Tanks

Authors: Haitham A. Hussein, Rozi Abdullah‏‎, Md Azlin Md Said ‎

Abstract:

Gravity separator tanks are used to separate oil from water in treatment units. Achieving the best flow ‎uniformity in a separator tank will improve the maximum removal efficiency of oil globules from water. ‎In this study, the effect on hydraulic performance of different baffle structure positions inside a tank ‎was investigated. Experimental data and 2D computation fluid dynamics were used for analysis. In the ‎numerical model, two-phase flow (drift flux model) was used to validate one-phase flow. For ‎laboratory measurements, the velocity fields were measured using an acoustic Doppler velocimeter. The ‎measurements were compared with the result of the computational model. The results of the ‎experimental and computational simulations indicate that the best location of a baffle structure is ‎achieved when the standard deviation of the velocity profile and the volume of the circulation zone ‎inside the tank are minimized.‎

Keywords: gravity separator tanks, CFD, baffle position, two phase flow, ADV, oil droplet

Procedia PDF Downloads 329
288 Sonocatalytic Treatment of Baker’s Yeast Wastewater by Using SnO2/TiO2 Composite

Authors: Didem Ildırar, Serap Fındık

Abstract:

Baker’s yeast industry uses molasses as a raw material. Molasses wastewater contains high molecular weight polymers called melanoidins. Melanoidins are obtained after the reactions between the amino acids and carbonyl groups in molasses. The molasses wastewater has high biochemical and chemical oxygen demand and dark brown color. If it is discharged to receiving bodies without any treatment, it prevents light penetration and dissolved oxygen level of the surface water decreases. Melanoidin compounds are toxic effect to the microorganism in water and there is a resistance to microbial degradation. Before discharging molasses wastewater, adequate treatment is necessary. In addition to changing environmental regulations, properties of treated wastewater must be improved. Advanced oxidation processes can be used to improve existing properties of wastewater. Sonochemical oxidation is one of the alternative methods. Sonochemical oxidation employs the use of ultrasound resulting in cavitation phenomena. In this study, decolorization and chemical oxygen demand removal (COD) of baker’s yeast effluent was investigated by using ultrasound. Baker’s yeast effluent was supplied from a factory which is located in the north of Turkey. An ultrasonic homogenizator was used for this study. Its operating frequency is 20kHz. SnO2/TiO2 catalyst has been used as sonocatalyst. The effects of the composite preparation method, mixing time while composite prepared, the molar ratio of SnO2/TiO2, the calcination temperature, and time, the catalyst amount were investigated on the treatment of baker’s yeast effluent. . According to the results, the prepared composite SnO2/TiO2 by using ultrasonic probe gave a better result than prepared composite by using an ultrasonic bath. Prepared composite by using an ultrasonic probe with a 4:1 molar ratio treated at 800°C for 60min gave a better result. By using this composite, optimum catalyst amount was 0.2g/l. At these conditions 26.6% decolorization was obtained. There was no COD removal at the studied conditions.

Keywords: baker’s yeast effluent, COD, decolorization, sonocatalyst, ultrasonic irradiation

Procedia PDF Downloads 322
287 Consideration of Starlight Waves Redshift as Produced by Friction of These Waves on Its Way through Space

Authors: Angel Pérez Sánchez

Abstract:

In 1929, a light redshift was discovered in distant galaxies and was interpreted as produced by galaxies moving away from each other at high speed. This interpretation led to the consideration of a new source of energy, which was called Dark Energy. Redshift is a loss of light wave frequency produced by galaxies moving away at high speed, but the loss of frequency can also be produced by the friction of light waves on their way to Earth. This friction is impossible because outer space is empty, but if it were not empty and a medium existed in this empty space, it would be possible. The consequences would be extraordinary because Universe acceleration and Dark Energy would be in doubt. This article presents evidence that empty space is actually a medium occupied by different particles, among them the most significant would-be Graviton or Higgs Boson, because let's not forget that gravity also affects empty space.

Keywords: Big Bang, dark energy, doppler effect, redshift, starlight frequency reduction, universe acceleration

Procedia PDF Downloads 63
286 Assessment of the Performance of the Sonoreactors Operated at Different Ultrasound Frequencies, to Remove Pollutants from Aqueous Media

Authors: Gabriela Rivadeneyra-Romero, Claudia del C. Gutierrez Torres, Sergio A. Martinez-Delgadillo, Victor X. Mendoza-Escamilla, Alejandro Alonzo-Garcia

Abstract:

Ultrasonic degradation is currently being used in sonochemical reactors to degrade pollutant compounds from aqueous media, as emerging contaminants (e.g. pharmaceuticals, drugs and personal care products.) because they can produce possible ecological impacts on the environment. For this reason, it is important to develop appropriate water and wastewater treatments able to reduce pollution and increase reuse. Pollutants such as textile dyes, aromatic and phenolic compounds, cholorobenzene, bisphenol-A and carboxylic acid and other organic pollutants, can be removed from wastewaters by sonochemical oxidation. The effect on the removal of pollutants depends on the type of the ultrasonic frequency used; however, not much studies have been done related to the behavior of the fluid into the sonoreactors operated at different ultrasonic frequencies. Based on the above, it is necessary to study the hydrodynamic behavior of the liquid generated by the ultrasonic irradiation to design efficient sonoreactors to reduce treatment times and costs. In this work, it was studied the hydrodynamic behavior of the fluid in sonochemical reactors at different frequencies (250 kHz, 500 kHz and 1000 kHz). The performances of the sonoreactors at those frequencies were simulated using computational fluid dynamics (CFD). Due to there is great sound speed gradient between piezoelectric and fluid, k-e models were used. Piezoelectric was defined as a vibration surface, to evaluate the different frequencies effect on the fluid into sonochemical reactor. Structured hexahedral cells were used to mesh the computational liquid domain, and fine triangular cells were used to mesh the piezoelectric transducers. Unsteady state conditions were used in the solver. Estimation of the dissipation rate, flow field velocities, Reynolds stress and turbulent quantities were evaluated by CFD and 2D-PIV measurements. Test results show that there is no necessary correlation between an increase of the ultrasonic frequency and the pollutant degradation, moreover, the reactor geometry and power density are important factors that should be considered in the sonochemical reactor design.

Keywords: CFD, reactor, ultrasound, wastewater

Procedia PDF Downloads 190
285 The Effect of Expanding the Early Pregnancy Assessment Clinic and COVID-19 on Emergency Department and Urgent Care Visits for Early Pregnancy Bleeding

Authors: Harley Bray, Helen Pymar, Michelle Liu, Chau Pham, Tomislav Jelic, Fran Mulhall

Abstract:

Background: Our study assesses the impact of the COVID-19 pandemic on early pregnancy assessment clinic (EPAC) referrals and the use of virtual consultation in Winnipeg, Manitoba. Our clinic expanded to accept referrals from all Winnipeg Emergency Department (ED)/Urgent Care (UC) sites beginning November 2019 to April 2020. By May 2020, the COVID-19 pandemic reached Manitoba and EPAC virtual care was expanded by performing hCG remotely and reviewing blood and ED/UC ultrasound results by phone. Methods: Emergency Department Information Systems (EDIS) and EPAC data reviewed ED/UC visits for pregnancy <20 weeks and vaginal bleeding 1-year pre-COVID (March 12, 2019, to March 11, 2020) and during COVID (March 12, 2020 (first case in Manitoba) to March 11, 2021). Results: There were fewer patient visits for vaginal bleeding or pregnancy of <20 weeks (4264 vs. 5180), diagnoses of threatened abortion (1895 vs. 2283), and ectopic pregnancy (78 vs. 97) during COVID compared with pre-COVID, respectively. ICD 10 codes were missing in 849 (20%) and 1183 (23%) of patients during COVID and pre-COVID, respectively. Wait times for all patient visits improved during COVID-19 compared to pre-COVID (5.1 ± 4.4 hours vs. 5.5 ± 3.8 hours), more patients received obstetrical ultrasounds, 761 (18%) vs. 787 (15%), and fewer patients returned within 30 days (1360 (32%) vs. 1848 (36%); p<0.01). EPAC saw 708 patients (218; 31% new ED/UC) during COVID-19 compared to 552 (37; 7% new ED/UC) pre-COVID. Fewer operative interventions for pregnancy loss (346 vs. 456) and retained products (236 vs. 272) were noted. Surgeries to treat ectopic pregnancy (106 vs 113) remained stable during the study time interval. Conclusion: Accurate identification of pregnancy complications was difficult, with over 20% missing ICD-10 diagnostic codes. There were fewer ED/UC visits and surgical management for threatened abortion during COVID-19, but ectopic pregnancy operative management remained unchanged.

Keywords: early pregnancy, ultrasound, COVID-19, obstetrics

Procedia PDF Downloads 20
284 In-House Fatty Meal Cholescintigraphy as a Screening Tool in Patients Presenting with Dyspepsia

Authors: Avani Jain, S. Shelley, M. Indirani, Shilpa Kalal, Jaykanth Amalachandran

Abstract:

Aim: To evaluate the prevalence of gall bladder dysfunction in patients with dyspepsia using In-House fatty meal cholescintigraphy. Materials & Methods: This study is a prospective cohort study. 59 healthy volunteers with no dyspeptic complaints and negative ultrasound and endoscopy were recruited in study. 61 patients having complaint of dyspepsia for duration of more than 6 months were included. All of them underwent 99mTc-Mebrofenin fatty meal cholescintigraphy following a standard protocol. Dynamic acquisitions were acquired for 120 minutes with an In-House fatty meal being given at 45th minute. Gall bladder emptying kinetics was determined with gall bladder ejection fractions (GBEF) calculated at 30minutes, 45minutes and at 60 minutes (30min, 45min & 60 min). Standardization of fatty meal was done for volunteers. Receiver operating characteristic (ROC) analysis was used assess the diagnostic accuracy of 3 time points (30min, 45min & 60 min) used for measuring gall bladder emptying. On the basis of cut off derived from volunteers, the patients were assessed for gall bladder dysfunction. Results: In volunteers, the GBEF at 30 min was 74.42±8.26 % (mean ±SD), at 45 min was 82.61 ± 6.5 % and at 60 min was 89.37±4.48%, compared to patients where at 30min it was 33.73±22.87%, at 45 min it was 43.03±26.97% and at 60 min it was 51.85±29.60%. The lower limit of GBEF in volunteers at 30 min was 60%, 45 min was 69% and at 60 min was 81%. ROC analysis showed that area under curve was largest for 30 min GBEF (0.952; 95% CI = 0.914-0.989) and that all the 3 measures were statistically significant (p < 0.005). Majority of the volunteers had 74% of gall bladder emptying by 30 minutes; hence it was taken as an optimum cutoff time to assess gall bladder contraction. > 60% GBEF at 30 min post fatty meal was considered as normal and < 60% GBEF as indicative of gall bladder dysfunction. In patients, various causes for dyspepsia were identified: GB dysfunction (63.93%), Peptic ulcer (8.19 %), Gastroesophageal reflux disease (8.19%), Gastritis (4.91%). In 18.03% of cases GB dysfunction coexisted with other gastrointestinal conditions. The diagnosis of functional dyspepsia was made in 14.75% of cases. Conclusions: Gall bladder dysfunction contributes significantly to the causation of dyspepsia. It could coexist with various other gastrointestinal diseases. Fatty meal was well tolerated and devoid of any side effects. Many patients who are labeled as functional dyspeptics could actually have gall bladder dysfunction. Hence as an adjunct to ultrasound and endoscopy, fatty meal cholescintigraphy can also be used as a screening modality in characterization of dyspepsia.

Keywords: in-house fatty meal, choescintigraphy, dyspepsia, gall bladder ejection fraction, functional dyspepsia

Procedia PDF Downloads 508
283 SNR Classification Using Multiple CNNs

Authors: Thinh Ngo, Paul Rad, Brian Kelley

Abstract:

Noise estimation is essential in today wireless systems for power control, adaptive modulation, interference suppression and quality of service. Deep learning (DL) has already been applied in the physical layer for modulation and signal classifications. Unacceptably low accuracy of less than 50% is found to undermine traditional application of DL classification for SNR prediction. In this paper, we use divide-and-conquer algorithm and classifier fusion method to simplify SNR classification and therefore enhances DL learning and prediction. Specifically, multiple CNNs are used for classification rather than a single CNN. Each CNN performs a binary classification of a single SNR with two labels: less than, greater than or equal. Together, multiple CNNs are combined to effectively classify over a range of SNR values from −20 ≤ SNR ≤ 32 dB.We use pre-trained CNNs to predict SNR over a wide range of joint channel parameters including multiple Doppler shifts (0, 60, 120 Hz), power-delay profiles, and signal-modulation types (QPSK,16QAM,64-QAM). The approach achieves individual SNR prediction accuracy of 92%, composite accuracy of 70% and prediction convergence one order of magnitude faster than that of traditional estimation.

Keywords: classification, CNN, deep learning, prediction, SNR

Procedia PDF Downloads 134
282 Measurement of Viscosity and Moisture of Oil in Supradistribution Transformers Using Ultrasonic Waves

Authors: Ehsan Kadkhodaie, Shahin Parvar, Soroush Senemar, Mostafa Shriat, Abdolrasoul Malekpour

Abstract:

The role of oil in supra distribution transformers is so critical and, several standards in determining the quality of oil have been offered. So far, moisture, viscosity and insulation protection of the oil have been measured based on mechanical and chemical methods and systems such as kart fisher, falling ball and TDM 4000 that most of these techniques are destructive and have many problems such as pollution. In this study, due to the properties of oil and also physical behavior of ultrasound wave new method was designed to in the determination of oil indicators including viscosity and moisture. The results show the oil viscosity can be found from the relationship μ = 42.086/√EE and moisture from (PLUS+) = −15.65 (PPM) + 26040 relationship.

Keywords: oil, viscosity, moisture, ultrasonic waves

Procedia PDF Downloads 581
281 Elevated Systemic Oxidative-Nitrosative Stress and Cerebrovascular Function in Professional Rugby Union Players: The Link to Impaired Cognition

Authors: Tom S. Owens, Tom A. Calverley, Benjamin S. Stacey, Christopher J. Marley, George Rose, Lewis Fall, Gareth L. Jones, Priscilla Williams, John P. R. Williams, Martin Steggall, Damian M. Bailey

Abstract:

Introduction and aims: Sports-related concussion (SRC) represents a significant and growing public health concern in rugby union, yet remains one of the least understood injuries facing the health community today. Alongside increasing SRC incidence rates, there is concern that prior recurrent concussion may contribute to long-term neurologic sequelae in later-life. This may be due to an accelerated decline in cerebral perfusion, a major risk factor for neurocognitive decline and neurodegeneration, though the underlying mechanisms remain to be established. The present study hypothesised that recurrent concussion in current professional rugby union players would result in elevated systemic oxidative-nitrosative stress, reflected by a free radical-mediated reduction in nitric oxide (NO) bioavailability and impaired cerebrovascular and cognitive function. Methodology: A longitudinal study design was adopted across the 2017-2018 rugby union season. Ethical approval was obtained from the University of South Wales Ethics Committee. Data collection is ongoing, and therefore the current report documents result from the pre-season and first half of the in-season data collection. Participants were initially divided into two subgroups; 23 professional rugby union players (aged 26 ± 5 years) and 22 non-concussed controls (27 ± 8 years). Pre-season measurements were performed for cerebrovascular function (Doppler ultrasound of middle cerebral artery velocity (MCAv) in response to hypocapnia/normocapnia/hypercapnia), cephalic venous concentrations of the ascorbate radical (A•-, electron paramagnetic resonance spectroscopy), NO (ozone-based chemiluminescence) and cognition (neuropsychometric tests). Notational analysis was performed to assess contact in the rugby group throughout each competitive game. Results: 1001 tackles and 62 injuries, including three concussions were observed across the first half of the season. However, no associations were apparent between number of tackles and any injury type (P > 0.05). The rugby group expressed greater oxidative stress as indicated by increased A•- (P < 0.05 vs. control) and a subsequent decrease in NO bioavailability (P < 0.05 vs. control). The rugby group performed worse in the Ray Auditory Verbal Learning Test B (RAVLT-B, learning, and memory) and the Grooved Pegboard test using both the dominant and non-dominant hands (visuomotor coordination, P < 0.05 vs. control). There were no between-group differences in cerebral perfusion at baseline (MCAv: 54 ± 13 vs. 59 ± 12, P > 0.05). Likewise, no between-group differences in CVRCO2Hypo (2.58 ± 1.01 vs. 2.58 ± 0.75, P > 0.05) or CVRCO2Hyper (2.69 ± 1.07 vs. 3.35 ± 1.28, P > 0.05) were observed. Conclusion: The present study identified that the rugby union players are characterized by impaired cognitive function subsequent to elevated systemic-oxidative-nitrosative stress. However, this appears to be independent of any functional impairment in cerebrovascular function. Given the potential long-term trajectory towards accelerated cognitive decline in populations exposed to SRC, prophylaxis to increase NO bioavailability warrants consideration.

Keywords: cognition, concussion, mild traumatic brain injury, rugby

Procedia PDF Downloads 176
280 Chronic Aflatoxin Exposure During Pregnancy Is Associated With Lower Fetal Growth Trajectories: A Prospective Cohort Study in Rural Ethiopia

Authors: K. Tesfamariam, S. Gebreyesus, C. Lachat, P. Kolsteren, S. De Saeger, M. De Boevre, A. Argaw

Abstract:

Aflatoxins are toxic secondary metabolites produced by Aspergillus fungi, which are ubiquitously present in the food supplies of low- and middle-income countries. Studies of maternal aflatoxin exposure and fetal outcomes are mainly focused on size at birth and the effect on intrauterine fetal growth has not been assessed using repeated longitudinal fetal biometry across gestation. Therefore, this study intends to assess the association between chronic aflatoxin exposure during pregnancy and fetal growth trajectories in a rural Ethiopian setting. In a prospective cohort study, we enrolled 492 pregnant women. A phlebotomist collected 5 mL of a venous blood sample from eligible women before 28 completed weeks of gestation and aflatoxin B1-lysine concentration was determined using liquid chromatography-tandem mass spectrometry. The mean (±SD) gestational age was 19.1 (3.71) weeks at enrollment, and 28.5 (3.51) and 34.5 (2.44) weeks of gestation at the second and third rounds of ultrasound measurements, respectively. Estimated fetal weight was expressed in centiles using the INTERGROWTH-21st reference. We fitted a multivariable linear mixed-effects model to estimate the rate of fetal growth between aflatoxin-exposed (i.e., aflatoxin B1-lysine concentration above or equal to the limit of detection) and non-exposed mothers in the study. Mothers had a mean (±SD) age of 26.0 (4.58) years. The median (P25, P75) serum AFB1-lysine concentration was 12.6 (0.93, 96.9) pg/mg albumin, and aflatoxin exposure was observed in 86.6% of maternal blood samples. Eighty-five percent of the women enrolled provided at least two ultrasound measurements for analysis. On average, the aflatoxin-exposed group had a significantly lower change over time in fetal weight-for-gestational age centile than the unexposed group (ß = -1.01 centiles/week, 95% CI: -1.87, -0.15, p = 0.02). Chronic maternal AF exposure is associated with lower fetal weight gain over time. Our findings emphasize the importance of nutrition-sensitive strategies to mitigate dietary aflatoxin exposure as well as adopting food safety measures in low-income settings, particularly during the fetal period of development.

Keywords: aflatoxin, fetal growth, low-income setting, mycotoxins

Procedia PDF Downloads 142
279 HPA Pre-Distorter Based on Neural Networks for 5G Satellite Communications

Authors: Abdelhamid Louliej, Younes Jabrane

Abstract:

Satellites are becoming indispensable assets to fifth-generation (5G) new radio architecture, complementing wireless and terrestrial communication links. The combination of satellites and 5G architecture allows consumers to access all next-generation services anytime, anywhere, including scenarios, like traveling to remote areas (without coverage). Nevertheless, this solution faces several challenges, such as a significant propagation delay, Doppler frequency shift, and high Peak-to-Average Power Ratio (PAPR), causing signal distortion due to the non-linear saturation of the High-Power Amplifier (HPA). To compensate for HPA non-linearity in 5G satellite transmission, an efficient pre-distorter scheme using Neural Networks (NN) is proposed. To assess the proposed NN pre-distorter, two types of HPA were investigated: Travelling Wave Tube Amplifier (TWTA) and Solid-State Power Amplifier (SSPA). The results show that the NN pre-distorter design presents EVM improvement by 95.26%. NMSE and ACPR were reduced by -43,66 dB and 24.56 dBm, respectively. Moreover, the system suffers no degradation of the Bit Error Rate (BER) for TWTA and SSPA amplifiers.

Keywords: satellites, 5G, neural networks, HPA, TWTA, SSPA, EVM, NMSE, ACPR

Procedia PDF Downloads 91
278 Hydrodynamic Characterisation of a Hydraulic Flume with Sheared Flow

Authors: Daniel Rowe, Christopher R. Vogel, Richard H. J. Willden

Abstract:

The University of Oxford’s recirculating water flume is a combined wave and current test tank with a 1 m depth, 1.1 m width, and 10 m long working section, and is capable of flow speeds up to 1 ms−1 . This study documents the hydrodynamic characteristics of the facility in preparation for experimental testing of horizontal axis tidal stream turbine models. The turbine to be tested has a rotor diameter of 0.6 m and is a modified version of one of two model-scale turbines tested in previous experimental campaigns. An Acoustic Doppler Velocimeter (ADV) was used to measure the flow at high temporal resolution at various locations throughout the flume, enabling the spatial uniformity and turbulence flow parameters to be investigated. The mean velocity profiles exhibited high levels of spatial uniformity at the design speed of the flume, 0.6 ms−1 , with variations in the three-dimensional velocity components on the order of ±1% at the 95% confidence level, along with a modest streamwise acceleration through the measurement domain, a target 5 m working section of the flume. A high degree of uniformity was also apparent for the turbulence intensity, with values ranging between 1-2% across the intended swept area of the turbine rotor. The integral scales of turbulence exhibited a far higher degree of variation throughout the water column, particularly in the streamwise and vertical scales. This behaviour is believed to be due to the high signal noise content leading to decorrelation in the sampling records. To achieve more realistic levels of vertical velocity shear in the flume, a simple procedure to practically generate target vertical shear profiles in open-channel flows is described. Here, the authors arranged a series of non-uniformly spaced parallel bars placed across the width of the flume and normal to the onset flow. By adjusting the resistance grading across the height of the working section, the downstream profiles could be modified accordingly, characterised by changes in the velocity profile power law exponent, 1/n. Considering the significant temporal variation in a tidal channel, the choice of the exponent denominator, n = 6 and n = 9, effectively provides an achievable range around the much-cited value of n = 7 observed at many tidal sites. The resulting flow profiles, which we intend to use in future turbine tests, have been characterised in detail. The results indicate non-uniform vertical shear across the survey area and reveal substantial corner flows, arising from the differential shear between the target vertical and cross-stream shear profiles throughout the measurement domain. In vertically sheared flow, the rotor-equivalent turbulence intensity ranges between 3.0-3.8% throughout the measurement domain for both bar arrangements, while the streamwise integral length scale grows from a characteristic dimension on the order of the bar width, similar to the flow downstream of a turbulence-generating grid. The experimental tests are well-defined and repeatable and serve as a reference for other researchers who wish to undertake similar investigations.

Keywords: acoustic doppler Velocimeter, experimental hydrodynamics, open-channel flow, shear profiles, tidal stream turbines

Procedia PDF Downloads 86
277 Emergency Physician Performance for Hydronephrosis Diagnosis and Grading Compared with Radiologist Assessment in Renal Colic: The EPHyDRA Study

Authors: Sameer A. Pathan, Biswadev Mitra, Salman Mirza, Umais Momin, Zahoor Ahmed, Lubna G. Andraous, Dharmesh Shukla, Mohammed Y. Shariff, Magid M. Makki, Tinsy T. George, Saad S. Khan, Stephen H. Thomas, Peter A. Cameron

Abstract:

Study objective: Emergency physician’s (EP) ability to identify hydronephrosis on point-of-care ultrasound (POCUS) has been assessed in the past using CT scan as the reference standard. We aimed to assess EP interpretation of POCUS to identify and grade the hydronephrosis in a direct comparison with the consensus-interpretation of POCUS by radiologists, and also to compare the EP and radiologist performance using CT scan as the criterion standard. Methods: Using data from a POCUS databank, a prospective interpretation study was conducted at an urban academic emergency department. All POCUS exams were performed on patients presenting with renal colic to the ED. Institutional approval was obtained for conducting this study. All the analyses were performed using Stata MP 14.0 (Stata Corp, College Station, Texas). Results: A total of 651 patients were included, with paired sets of renal POCUS video clips and the CT scan performed at the same ED visit. Hydronephrosis was reported in 69.6% of POCUS exams by radiologists and 72.7% of CT scans (p=0.22). The κ for consensus interpretation of POCUS between the radiologists to detect hydronephrosis was 0.77 (0.72 to 0.82) and weighted κ for grading the hydronephrosis was 0.82 (0.72 to 0.90), interpreted as good to very good. Using CT scan findings as the criterion standard, Eps had an overall sensitivity of 81.1% (95% CI: 79.6% to 82.5%), specificity of 59.4% (95% CI: 56.4% to 62.5%), PPV of 84.3% (95% CI: 82.9% to 85.7%), and NPV of 53.8% (95% CI: 50.8% to 56.7%); compared to radiologist sensitivity of 85.0% (95% CI: 82.5% to 87.2%), specificity of 79.7% (95% CI: 75.1% to 83.7%), PPV of 91.8% (95% CI: 89.8% to 93.5%), and NPV of 66.5% (95% CI: 61.8% to 71.0%). Testing for a report of moderate or high degree of hydronephrosis, specificity of EP was 94.6% (95% CI: 93.7% to 95.4%) and to 99.2% (95% CI: 98.9% to 99.5%) for identifying severe hydronephrosis alone. Conclusion: EP POCUS interpretations were comparable to the radiologists for identifying moderate to severe hydronephrosis using CT scan results as the criterion standard. Among patients with moderate or high pre-test probability of ureteric calculi, as calculated by the STONE-score, the presence of moderate to severe (+LR 6.3 and –LR 0.69) or severe hydronephrosis (+LR 54.4 and –LR 0.57) was highly diagnostic of the stone disease. Low dose CT is indicated in such patients for evaluation of stone size and location.

Keywords: renal colic, point-of-care, ultrasound, bedside, emergency physician

Procedia PDF Downloads 284
276 Mineralized Nanoparticles as a Contrast Agent for Ultrasound and Magnetic Resonance Imaging

Authors: Jae Won Lee, Kyung Hyun Min, Hong Jae Lee, Sang Cheon Lee

Abstract:

To date, imaging techniques have attracted much attention in medicine because the detection of diseases at an early stage provides greater opportunities for successful treatment. Consequently, over the past few decades, diverse imaging modalities including magnetic resonance (MR), positron emission tomography, computed tomography, and ultrasound (US) have been developed and applied widely in the field of clinical diagnosis. However, each of the above-mentioned imaging modalities possesses unique strengths and intrinsic weaknesses, which limit their abilities to provide accurate information. Therefore, multimodal imaging systems may be a solution that can provide improved diagnostic performance. Among the current medical imaging modalities, US is a widely available real-time imaging modality. It has many advantages including safety, low cost and easy access for patients. However, its low spatial resolution precludes accurate discrimination of diseased region such as cancer sites. In contrast, MR has no tissue-penetrating limit and can provide images possessing exquisite soft tissue contrast and high spatial resolution. However, it cannot offer real-time images and needs a comparatively long imaging time. The characteristics of these imaging modalities may be considered complementary, and the modalities have been frequently combined for the clinical diagnostic process. Biominerals such as calcium carbonate (CaCO3) and calcium phosphate (CaP) exhibit pH-dependent dissolution behavior. They demonstrate pH-controlled drug release due to the dissolution of minerals in acidic pH conditions. In particular, the application of this mineralization technique to a US contrast agent has been reported recently. The CaCO3 mineral reacts with acids and decomposes to generate calcium dioxide (CO2) gas in an acidic environment. These gas-generating mineralized nanoparticles generated CO2 bubbles in the acidic environment of the tumor, thereby allowing for strong echogenic US imaging of tumor tissues. On the basis of this previous work, it was hypothesized that the loading of MR contrast agents into the CaCO3 mineralized nanoparticles may be a novel strategy in designing a contrast agent for dual imaging. Herein, CaCO3 mineralized nanoparticles that were capable of generating CO2 bubbles to trigger the release of entrapped MR contrast agents in response to tumoral acidic pH were developed for the purposes of US and MR dual-modality imaging of tumors. Gd2O3 nanoparticles were selected as an MR contrast agent. A key strategy employed in this study was to prepare Gd2O3 nanoparticle-loaded mineralized nanoparticles (Gd2O3-MNPs) using block copolymer-templated CaCO3 mineralization in the presence of calcium cations (Ca2+), carbonate anions (CO32-) and positively charged Gd2O3 nanoparticles. The CaCO3 core was considered suitable because it may effectively shield Gd2O3 nanoparticles from water molecules in the blood (pH 7.4) before decomposing to generate CO2 gas, triggering the release of Gd2O3 nanoparticles in tumor tissues (pH 6.4~7.4). The kinetics of CaCO3 dissolution and CO2 generation from the Gd2O3-MNPs were examined as a function of pH and pH-dependent in vitro magnetic relaxation; additionally, the echogenic properties were estimated to demonstrate the potential of the particles for the tumor-specific US and MR imaging.

Keywords: calcium carbonate, mineralization, ultrasound imaging, magnetic resonance imaging

Procedia PDF Downloads 236
275 Shock and Particle Velocity Determination from Microwave Interrogation

Authors: Benoit Rougier, Alexandre Lefrancois, Herve Aubert

Abstract:

Microwave interrogation in the range 10-100 GHz is identified as an advanced technique to investigate simultaneously shock and particle velocity measurements. However, it requires the understanding of electromagnetic wave propagation in a multi-layered moving media. The existing models limit their approach to wave guides or evaluate the velocities with a fitting method, restricting therefore the domain of validity and the precision of the results. Moreover, few data of permittivity on high explosives at these frequencies under dynamic compression have been reported. In this paper, shock and particle velocities are computed concurrently for steady and unsteady shocks for various inert and reactive materials, via a propagation model based on Doppler shifts and signal amplitude. Refractive index of the material under compression is also calculated. From experimental data processing, it is demonstrated that Hugoniot curve can be evaluated. The comparison with published results proves the accuracy of the proposed method. This microwave interrogation technique seems promising for shock and detonation waves studies.

Keywords: electromagnetic propagation, experimental setup, Hugoniot measurement, shock propagation

Procedia PDF Downloads 213
274 Influence of the Local External Pressure on Measured Parameters of Cutaneous Microcirculation

Authors: Irina Mizeva, Elena Potapova, Viktor Dremin, Mikhail Mezentsev, Valeri Shupletsov

Abstract:

The local tissue perfusion is regulated by the microvascular tone which is under the control of a number of physiological mechanisms. Laser Doppler flowmetry (LDF) together with wavelet analyses is the most commonly used technique to study the regulatory mechanisms of cutaneous microcirculation. External factors such as temperature, local pressure of the probe on the skin, etc. influence on the blood flow characteristics and are used as physiological tests to evaluate microvascular regulatory mechanisms. Local probe pressure influences on the microcirculation parameters measured by optical methods: diffuse reflectance spectroscopy, fluorescence spectroscopy, and LDF. Therefore, further study of probe pressure effects can be useful to improve the reliability of optical measurement. During pressure tests variation of the mean perfusion measured by means of LDF usually is estimated. An additional information concerning the physiological mechanisms of the vascular tone regulation system in response to local pressure can be obtained using spectral analyses of LDF samples. The aim of the present work was to develop protocol and algorithm of data processing appropriate for study physiological response to the local pressure test. Involving 6 subjects (20±2 years) and providing 5 measurements for every subject we estimated intersubject and-inter group variability of response of both averaged and oscillating parts of the LDF sample on external surface pressure. The final purpose of the work was to find special features which further can be used in wider clinic studies. The cutaneous perfusion measurements were carried out by LAKK-02 (SPE LAZMA Ltd., Russia), the skin loading was provided by the originally designed device which allows one to distribute the pressure around the LDF probe. The probe was installed on the dorsal part of the distal finger of the index figure. We collected measurements continuously for one hour and varied loading from 0 to 180mmHg stepwise with a step duration of 10 minutes. Further, we post-processed the samples using the wavelet transform and traced the energy of oscillations in five frequency bands over time. Weak loading leads to pressure-induced vasodilation, so one should take into account that the perfusion measured under pressure conditions will be overestimated. On the other hand, we revealed a decrease in endothelial associated fluctuations. Further loading (88 mmHg) induces amplification of pulsations in all frequency bands. We assume that such loading leads to a higher number of closed capillaries, higher input of arterioles in the LDF signal and as a consequence more vivid oscillations which mainly are formed in arterioles. External pressure higher than 144 mmHg leads to the decrease of oscillating components, after removing the loading very rapid restore of the tissue perfusion takes place. In this work, we have demonstrated that local skin loading influence on the microcirculation parameters measured by optic technique; this should be taken into account while developing portable electronic devices. The proposed protocol of local loading allows one to evaluate PIV as far as to trace dynamic of blood flow oscillations. This study was supported by the Russian Science Foundation under project N 18-15-00201.

Keywords: blood microcirculation, laser Doppler flowmetry, pressure-induced vasodilation, wavelet analyses blood

Procedia PDF Downloads 150
273 Clinicopathological Characteristics in Male Breast Cancer: A Case Series and Literature Review

Authors: Mohamed Shafi Mahboob Ali

Abstract:

Male breast cancer (MBC) is a rare entity with overall cases reported less than 1%. However, the incidence of MBC is regularly rising every year. Due to the lack of data on MBC, diagnosis and treatment are tailored to female breast cancer. MBC risk increases with age and is usually diagnosed ten years late as the disease progression is slow compared to female breast cancer (FBC). The most common feature of MBC is an intra-ductal variant, and often, upon diagnosis, the stage of the disease is already advanced. The Prognosis of MBC is often flawed, but new treatment modalities are emerging with the current knowledge and advancement. We presented a series of male breast cancer in our center, highlighting the clinicopathological, radiological and treatment options.

Keywords: male, breast, cancer, clinicopathology, ultrasound, CT scan

Procedia PDF Downloads 98
272 Classification of Random Doppler-Radar Targets during the Surveillance Operations

Authors: G. C. Tikkiwal, Mukesh Upadhyay

Abstract:

During the surveillance operations at war or peace time, the Radar operator gets a scatter of targets over the screen. This may be a tracked vehicle like tank vis-à-vis T72, BMP etc, or it may be a wheeled vehicle like ALS, TATRA, 2.5Tonne, Shaktiman or moving the army, moving convoys etc. The radar operator selects one of the promising targets into single target tracking (STT) mode. Once the target is locked, the operator gets a typical audible signal into his headphones. With reference to the gained experience and training over the time, the operator then identifies the random target. But this process is cumbersome and is solely dependent on the skills of the operator, thus may lead to misclassification of the object. In this paper, we present a technique using mathematical and statistical methods like fast fourier transformation (FFT) and principal component analysis (PCA) to identify the random objects. The process of classification is based on transforming the audible signature of target into music octave-notes. The whole methodology is then automated by developing suitable software. This automation increases the efficiency of identification of the random target by reducing the chances of misclassification. This whole study is based on live data.

Keywords: radar target, FFT, principal component analysis, eigenvector, octave-notes, DSP

Procedia PDF Downloads 394
271 Validation of a Placebo Method with Potential for Blinding in Ultrasound-Guided Dry Needling

Authors: Johnson C. Y. Pang, Bo Pengb, Kara K. L. Reevesc, Allan C. L. Fud

Abstract:

Objective: Dry needling (DN) has long been used as a treatment method for various musculoskeletal pain conditions. However, the evidence level of the studies was low due to the limitations of the methodology. Lack of randomization and inappropriate blinding are potentially the main sources of bias. A method that can differentiate clinical results due to the targeted experimental procedure from its placebo effect is needed to enhance the validity of the trial. Therefore, this study aimed to validate the method as a placebo ultrasound(US)-guided DN for patients with knee osteoarthritis (KOA). Design: This is a randomized controlled trial (RCT). Ninety subjects (25 males and 65 females) aged between 51 and 80 (61.26±5.57) with radiological KOA were recruited and randomly assigned into three groups with a computer program. Group 1 (G1) received real US-guided DN, Group 2 (G2) received placebo US-guided DN, and Group 3 (G3) was the control group. Both G1 and G2 subjects received the same procedure of US-guided DN, except the US monitor was turned off in G2, blinding the G2 subjects to the incorporation of faux US guidance. This arrangement created the placebo effect intended to permit comparison of their results to those who received actual US-guided DN. Outcome measures, including the visual analog scale (VAS) and Knee injury and Osteoarthritis Outcome Score (KOOS) subscales of pain, symptoms and quality of life (QOL), were analyzed by repeated-measures analysis of covariance (ANCOVA) for time effects and group effects. The data regarding the perception of receiving real US-guided DN or placebo US-guided DN were analyzed by the chi-squared test. The missing data were analyzed with the intention-to-treat (ITT) approach if more than 5% of the data were missing. Results: The placebo US-guided DN (G2) subjects had the same perceptions as the use of real US guidance in the advancement of DN (p<0.128). G1 had significantly higher pain reduction (VAS and KOOS-pain) than G2 and G3 at 8 weeks (both p<0.05) only. There was no significant difference between G2 and G3 at 8 weeks (both p>0.05). Conclusion: The method with the US monitor turned off during the application of DN is credible for blinding the participants and allowing researchers to incorporate faux US guidance. The validated placebo US-guided DN technique can aid in investigations of the effects of US-guided DN with short-term effects of pain reduction for patients with KOA. Acknowledgment: This work was supported by the Caritas Institute of Higher Education [grant number IDG200101].

Keywords: reliability, jumping, 3D motion analysis, anterior crucial ligament reconstruction

Procedia PDF Downloads 119
270 Coexisting Pathology of Unruptured Ectopic Pregnancy With Concurrent Ipsilateral Dermoid Cyst: A Rare Occurrence

Authors: Anne Nicole Fuentes

Abstract:

A 29 year old Gravida 1 Para 0 who presented at the hospital with a 5-week history of amenorrhea, abdominal pain and vaginal bleeding. Transvaginal ultrasound revealed 3 pathologic findings : Tuboovarian complex on the right adnexa, a complex mass indicative of an unruptured ectopic pregnancy and right ovarian new growth probably endometrioma. Pelvic laparotomy was done and histopathologic finding revealed tubal pregnancy, right and mature cystic teratoma of the right ovary. This case report demonstrates the importance of considering the coexistence of different gynecologic pathologies in the same patient and clinical importance of an accurate diagnostic evaluation.

Keywords: mature cystic teratoma, ectopic pregnancy, Tuboovarian abscess, bHCG

Procedia PDF Downloads 144
269 Quantitative Texture Analysis of Shoulder Sonography for Rotator Cuff Lesion Classification

Authors: Chung-Ming Lo, Chung-Chien Lee

Abstract:

In many countries, the lifetime prevalence of shoulder pain is up to 70%. In America, the health care system spends 7 billion per year about the healthy issues of shoulder pain. With respect to the origin, up to 70% of shoulder pain is attributed to rotator cuff lesions This study proposed a computer-aided diagnosis (CAD) system to assist radiologists classifying rotator cuff lesions with less operator dependence. Quantitative features were extracted from the shoulder ultrasound images acquired using an ALOKA alpha-6 US scanner (Hitachi-Aloka Medical, Tokyo, Japan) with linear array probe (scan width: 36mm) ranging from 5 to 13 MHz. During examination, the postures of the examined patients are standard sitting position and are followed by the regular routine. After acquisition, the shoulder US images were drawn out from the scanner and stored as 8-bit images with pixel value ranging from 0 to 255. Upon the sonographic appearance, the boundary of each lesion was delineated by a physician to indicate the specific pattern for analysis. The three lesion categories for classification were composed of 20 cases of tendon inflammation, 18 cases of calcific tendonitis, and 18 cases of supraspinatus tear. For each lesion, second-order statistics were quantified in the feature extraction. The second-order statistics were the texture features describing the correlations between adjacent pixels in a lesion. Because echogenicity patterns were expressed via grey-scale. The grey-scale co-occurrence matrixes with four angles of adjacent pixels were used. The texture metrics included the mean and standard deviation of energy, entropy, correlation, inverse different moment, inertia, cluster shade, cluster prominence, and Haralick correlation. Then, the quantitative features were combined in a multinomial logistic regression classifier to generate a prediction model of rotator cuff lesions. Multinomial logistic regression classifier is widely used in the classification of more than two categories such as the three lesion types used in this study. In the classifier, backward elimination was used to select a feature subset which is the most relevant. They were selected from the trained classifier with the lowest error rate. Leave-one-out cross-validation was used to evaluate the performance of the classifier. Each case was left out of the total cases and used to test the trained result by the remaining cases. According to the physician’s assessment, the performance of the proposed CAD system was shown by the accuracy. As a result, the proposed system achieved an accuracy of 86%. A CAD system based on the statistical texture features to interpret echogenicity values in shoulder musculoskeletal ultrasound was established to generate a prediction model for rotator cuff lesions. Clinically, it is difficult to distinguish some kinds of rotator cuff lesions, especially partial-thickness tear of rotator cuff. The shoulder orthopaedic surgeon and musculoskeletal radiologist reported greater diagnostic test accuracy than general radiologist or ultrasonographers based on the available literature. Consequently, the proposed CAD system which was developed according to the experiment of the shoulder orthopaedic surgeon can provide reliable suggestions to general radiologists or ultrasonographers. More quantitative features related to the specific patterns of different lesion types would be investigated in the further study to improve the prediction.

Keywords: shoulder ultrasound, rotator cuff lesions, texture, computer-aided diagnosis

Procedia PDF Downloads 284
268 Turbulence Measurement Over Rough and Smooth Bed in Open Channel Flow

Authors: Kirti Singh, Kesheo Prasad

Abstract:

A 3D Acoustic Doppler velocimeter was used in the current investigation to quantify the mean and turbulence characteristics in non-uniform open-channel flows. Results are obtained from studies done in the laboratory, analysing the behavior of sand particles under turbulent open channel flow conditions flowing through rough, porous beds. Data obtained from ADV is used to calculate turbulent flow characteristics, Reynolds stresses and turbulent kinetic energy. Theoretical formulations for the distribution of Reynolds stress and the vertical velocity have been constructed using the Reynolds equation and the continuity equation of 2D open-channel flow. The measured Reynolds stress profile and the vertical velocity are comparable with the derived expressions. This study uses the Navier-Stokes equations for analysing the behavior of the vertical velocity profile in the dominant region of full-fledged turbulent flows in open channels, and it gives a new origination of the profile. For both wide and narrow open channels, this origination can estimate the time-averaged primary velocity in the turbulent boundary layer's outer region.

Keywords: turbulence, bed roughness, logarithmic law, shear stress correlations, ADV, Reynolds shear stress

Procedia PDF Downloads 108
267 Effect of Enzymatic Hydrolysis and Ultrasounds Pretreatments on Biogas Production from Corn Cob

Authors: N. Pérez-Rodríguez, D. García-Bernet, A. Torrado-Agrasar, J. M. Cruz, A. B. Moldes, J. M. Domínguez

Abstract:

World economy is based on non-renewable, fossil fuels such as petroleum and natural gas, which entails its rapid depletion and environmental problems. In EU countries, the objective is that at least 20% of the total energy supplies in 2020 should be derived from renewable resources. Biogas, a product of anaerobic degradation of organic substrates, represents an attractive green alternative for meeting partial energy needs. Nowadays, trend to circular economy model involves efficiently use of residues by its transformation from waste to a new resource. In this sense, characteristics of agricultural residues (that are available in plenty, renewable, as well as eco-friendly) propitiate their valorisation as substrates for biogas production. Corn cob is a by-product obtained from maize processing representing 18 % of total maize mass. Corn cob importance lies in the high production of this cereal (more than 1 x 109 tons in 2014). Due to its lignocellulosic nature, corn cob contains three main polymers: cellulose, hemicellulose and lignin. Crystalline, highly ordered structures of cellulose and lignin hinders microbial attack and subsequent biogas production. For the optimal lignocellulose utilization and to enhance gas production in anaerobic digestion, materials are usually submitted to different pretreatment technologies. In the present work, enzymatic hydrolysis, ultrasounds and combination of both technologies were assayed as pretreatments of corn cob for biogas production. Enzymatic hydrolysis pretreatment was started by adding 0.044 U of Ultraflo® L feruloyl esterase per gram of dry corncob. Hydrolyses were carried out in 50 mM sodium-phosphate buffer pH 6.0 with a solid:liquid proportion of 1:10 (w/v), at 150 rpm, 40 ºC and darkness for 3 hours. Ultrasounds pretreatment was performed subjecting corn cob, in 50 mM sodium-phosphate buffer pH 6.0 with a solid: liquid proportion of 1:10 (w/v), at a power of 750W for 1 minute. In order to observe the effect of the combination of both pretreatments, some samples were initially sonicated and then they were enzymatically hydrolysed. In terms of methane production, anaerobic digestion of the corn cob pretreated by enzymatic hydrolysis was positive achieving 290 L CH4 kg MV-1 (compared with 267 L CH4 kg MV-1 obtained with untreated corn cob). Although the use of ultrasound as the only pretreatment resulted detrimentally (since gas production decreased to 244 L CH4 kg MV-1 after 44 days of anaerobic digestion), its combination with enzymatic hydrolysis was beneficial, reaching the highest value (300.9 L CH4 kg MV-1). Consequently, the combination of both pretreatments improved biogas production from corn cob.

Keywords: biogas, corn cob, enzymatic hydrolysis, ultrasound

Procedia PDF Downloads 267
266 A Case of Umbilical Arterial Atresia in the Third Trimester of Pregnancy

Authors: Caixiu Pu, Zhen Chen

Abstract:

We present the rare case of umbilical arterial atresia, leading to a good outcome and provide clinical and pathological findings. A 27-year-old nulliparous first gravida with PGDM was found single umbilical artery(SUA) by routine ultrasound san at 30 weeeks of gestation. Fetal status was monitored weekly. A healthy male newborn was delivered by cesarean section at 39 weeks. The umbilical cord was overly twisted and no thrombus was found along the whole diseased vessel. The cause of umbilical arterial atresia was unclear, and the correct diagnosis was a challenge. Expected clinical management was recommended, in which sonographic diagnosis may play a very important part.

Keywords: pregnancy, single umbilical artery, umbilical arterial atresia, prenatal diagnosis

Procedia PDF Downloads 33