TRACE/FRAPTRAN Analysis of Kuosheng Nuclear Power Plant Dry-Storage System
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
TRACE/FRAPTRAN Analysis of Kuosheng Nuclear Power Plant Dry-Storage System

Authors: J. R. Wang, Y. Chiang, W. Y. Li, H. T. Lin, H. C. Chen, C. Shih, S. W. Chen

Abstract:

The dry-storage systems of nuclear power plants (NPPs) in Taiwan have become one of the major safety concerns. There are two steps considered in this study. The first step is the verification of the TRACE by using VSC-17 experimental data. The results of TRACE were similar to the VSC-17 data. It indicates that TRACE has the respectable accuracy in the simulation and analysis of the dry-storage systems. The next step is the application of TRACE in the dry-storage system of Kuosheng NPP (BWR/6). Kuosheng NPP is the second BWR NPP of Taiwan Power Company. In order to solve the storage of the spent fuels, Taiwan Power Company developed the new dry-storage system for Kuosheng NPP. In this step, the dry-storage system model of Kuosheng NPP was established by TRACE. Then, the steady state simulation of this model was performed and the results of TRACE were compared with the Kuosheng NPP data. Finally, this model was used to perform the safety analysis of Kuosheng NPP dry-storage system. Besides, FRAPTRAN was used tocalculate the transient performance of fuel rods.

Keywords: BWR, TRACE, FRAPTRAN, Dry-Storage.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1093774

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2030

References:


[1] C. Shih, Y. S. Tseng,"The final report of parallel validation study for KSDSS,”2013.
[2] NRC, "TRACE V5.0 User’s Manual”, Office of Nuclear Regulatory Research, 2010.
[3] F.Mascari, A. M.Colletti, B. G. Woods, A. M. Costa, K. Welter, M. L. Richiusa, F. D. Rosa, F.D'Auria, G.Vella, "Analyses of Natural Circulation Phenomena Typical of the MASLWR by Using The TRACE V5 Code,” 2013.
[4] Pacific Northwest Laboratory, "Performance testing and Analyses of the VSC-17 Ventilated Concrete Cask,” 1992.
[5] Taipower Co., "FSAR of Kuosheng NPP Dry Storage System,”2013.