Abstract:

This paper evaluates the Total Vector Error of an estimated Phasor as define in IEEE C37.118 standard within different medium access in Local Area Networks (LAN). Three different LAN models (CSMA/CD, CSMA/AMP and Switched Ethernet) are evaluated. The Total Vector Error of the estimated Phasor has been evaluated for the effect of Nodes Number under the standardized network Band-width values defined in IEC 61850-9-2 communication standard (i.e. 0.1, 1 and 10 Gbps).

Keywords: Phasor, Local Area Network, Total Vector Error, IEEE C37.118, IEC 61850.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1337011

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4102

References:


[1] C. P. Steinmetz, Theory and calculation of alternating current phenomena vol. 4: McGraw-Hill Book Company, inc., 1916.
[2] IEEE, "IEEE Std C37.118™- Standard for Synchrophasor for Power Systems," ed, 2005.
[3] A. Phadke, J. Thorp, and M. Adamiak, "A new measurement technique for tracking voltage phasors, local system frequency, and rate of change of frequency," Power Apparatus and Systems, IEEE Transactions on, pp. 1025-1038, 1983.
[4] A. Phadke, "Synchronized phasor measurements in power systems," Computer Applications in Power, IEEE, vol. 6, pp. 10-15, 1993.
[5] H. Ma and A. A. Girgis, "Identification and tracking of harmonic sources in a power system using a Kalman filter," Power Delivery, IEEE Transactions on, vol. 11, pp. 1659-1665, 1996.
[6] V. M. M. Saiz and J. B. Guadalupe, "Application of Kalman filtering for continuous real-time tracking of power system harmonics," in Generation, Transmission and Distribution, IEE Proceedings-, 1997, pp. 13-20.
[7] P. Dash, A. Pradhan, and G. Panda, "Frequency estimation of distorted power system signals using extended complex Kalman filter," Power Delivery, IEEE Transactions on, vol. 14, pp. 761-766, 1999.
[8] S. Bittanti and S. M. Savaresi, "On the parametrization and design of an extended Kalman filter frequency tracker," Automatic Control, IEEE Transactions on, vol. 45, pp. 1718-1724, 2000.
[9] P. Dash, R. Jena, G. Panda, and A. Routray, "An extended complex Kalman filter for frequency measurement of distorted signals," Instrumentation and Measurement, IEEE Transactions on, vol. 49, pp. 746-753, 2000.
[10] P. Dash, A. Pradhan, G. Panda, and R. Jena, "Harmonics estimation in stressed electric power networks," in Power Electronics and Drive Systems, 2001. Proceedings., 2001 4th IEEE International Conference on, 2001, pp. 782-788.
[11] R. Aghazadeh, H. Lesani, M. Sanaye-Pasand, and B. Ganji, "New technique for frequency and amplitude estimation of power system signals," in Generation, Transmission and Distribution, IEE Proceedings-, 2005, pp. 435-440.
[12] "IEC 61850-9-2 LE: Implementation Guideline for Digital Interface to Instrument Transformers Using IEC 61850 9-2," ed: UCA International Users Group.
[13] A. A. Girgis, W. B. Chang, and E. B. Makram, "A digital recursive measurement scheme for online tracking of power system harmonics," Power Delivery, IEEE Transactions on, vol. 6, pp. 1153-1160, 1991.
[14] M. Ohlin, D. Henriksson, and A. Cervin, "TrueTime 1.5 Reference Manual," Department of Automatic Control, Lund University, Sweden, 2007.
[15] M. Passerini, "Design of an ECMA368 simulator for evaluating network performance for electrical substation applications based on IEC618510," Master’s Thesis Project, KTH Electrical Engineering, KTH Royal Institute of Technlogy, Stockholm, Sweden September 2008, XR-EERT 2008: 021.
[16] A. Fiorenza and J. Kjellsson, "Performance Evaluation of an ECMA368 network in an electrical substation application based on IEC61850," ABB Corporate Research‏, Sweden, 2008.