Seismic Rehabilitation of R/C Buildings Designed with Earlier Technical Standards
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
Seismic Rehabilitation of R/C Buildings Designed with Earlier Technical Standards

Authors: Stefano Sorace, Gloria Terenzi

Abstract:

The seismic rehabilitation designs of two reinforced concrete school buildings, representative of a wide stock of similar edifices designed under earlier editions of the Italian Technical Standards, are presented in this paper. The mutual retrofit solution elaborated for the two buildings consists in the incorporation of a dissipative bracing system including pressurized fluid viscous springdampers as passive protective devices. The mechanical parameters, layouts and locations selected for the constituting elements of the system; the architectural renovation projects developed to properly incorporate the structural interventions and improve the appearance of the buildings; highlights of the installation works already completed in one of the two structures; and a synthesis of the performance assessment analyses carried out in original and rehabilitated conditions, are illustrated. The results of the analyses show a remarkable enhancement of the seismic response capacities of both structures. This allows reaching the high performance objectives postulated in the retrofit designs with much lower costs and architectural intrusion as compared to traditional rehabilitation interventions designed for the same objectives.

Keywords: Seismic rehabilitation, R/C structures, performance analysis, dissipative braces, fluid viscous dampers.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1072674

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1598

References:


[1] S. Sorace, and G. Terenzi, "Iterative design procedure of fluid viscous devices included in braced frames", in Proc. EURODYN -99 - 4th European Conference on Structural Dynamics, 1999, pp. 169-174.
[2] S. Sorace, and G. Terenzi, "Large-scale experimental validation of a design procedure for damped braced steel structures", in Proc. STESSA 2003 - 4th International Conference on the Behaviour of Steel Structures in Seismic Areas, 2003, pp. 657-662.
[3] F. J. Molina, S. Sorace, G. Terenzi, G. Magonette, and B. Viaccoz, "Seismic tests on reinforced concrete and steel frames retrofitted with dissipative braces", Earthquake Engineering and Structural Dynamics, vol. 33, no. 12, pp. 1373-1394, Nov. 2004.
[4] S. Sorace, and G. Terenzi, "Seismic Protection of Frame Structures by Fluid Viscous Damped Braces", Journal of Structural Engineering, ASCE, vol. 134, no. 1, pp. 45-55, Jan. 2008.
[5] S. Sorace, and G. Terenzi, "Fluid viscous damped-based seismic retrofit strategies of steel structures: General concepts and design applications", Advanced Steel Construction, vol. 5, no. 3, pp. 322-339, Sep. 2009.
[6] S. Sorace, and G. Terenzi, "Shaking table and numerical seismic performance evaluation of a fluid viscous-dissipative bracing system", Earthquake Spectra, vol. 28, no. 4, Nov. 2012.
[7] S. Sorace, and G. Terenzi, "Non-linear dynamic modelling and design procedure of FV spring-dampers for base isolation", Engineering Structures, vol. 23, no. 12, pp. 1556-1567, Dec. 2001.
[8] S. Sorace, and G. Terenzi, "Non-linear dynamic design procedure of FV spring-dampers for base isolation ÔÇö Frame building applications", Engineering Structures, vol. 23, no. 12, pp. 1568-1576, Dec. 2001.
[9] S. Sorace, G. Terenzi, G. Magonette, and F. J. Molina, "Experimental investigation on a base isolation system incorporating steel-Teflon sliders and pressurized fluid viscous spring dampers", Earthquake Engineering and Structural Dynamics, vol. 34, no. 2, pp. 225-242, Feb. 2008.
[10] G. Pekcan, J. B. Mander, and S.S. Chen, "The Seismic response of a 1:3 scale model R.C. structure with elastomeric spring dampers", Earthquake Spectra, vol. 11, no. 2, pp. 249-267, May 1995.
[11] S. Sorace, and G., Terenzi, "Analysis and demonstrative application of a base isolation/supplemental damping technology", Earthquake Spectra, vol. 24, no. 3, pp. 775-793, Aug. 2008.
[12] Computers & Structures Inc., SAP2000NL. Structural analysis programs - Theoretical and users manual, Release No. 14.09. Berkeley, CA: CSI 2012.
[13] S. Sorace, and G. Terenzi, "The damped cable system for seismic protection of frame structures ÔÇö Part I: General concepts, testing and modelling", Earthquake Engineering and Structural Dynamics, vol. 41, no. 5, pp. 915-928, Apr. 2012.
[14] S. Sorace, and G. Terenzi, "The damped cable system for seismic protection of frame structures ÔÇö Part II: design and application", Earthquake Engineering and Structural Dynamics, vol. 41, no. 5, pp. 929-947, Apr. 2012.
[15] S. Sorace, G. Terenzi, and G. Bertino, "Viscous dissipative, ductilitybased and elastic bracing design solutions for an indoor sports steel building", Advanced Steel Construction, vol. 8, no. 3, pp. 295-316, Sep. 2012.
[16] Italian Council of Public Works, Technical Standards on Constructions
[in Italian]. Rome, Italy: ICPW, 2008.
[17] T. Takeda, M. A. Sozen, and N. N. Nielsen, "Reinforced concrete response to simulated earthquakes," Journal of the Structural Division, ASCE, vol. 96, no. 12, pp. 2557-2573, Dec. 1970.
[18] ASCE/SEI 41-06, Seismic rehabilitation of existing buildings Reston, VA: American Society of Civil Engineers - Structural Engineering Institute, 2006.
[19] Jarret SL, "Shock-control Technologies", URL http://www.introini.info, 2012.