WASET
	%0 Journal Article
	%A A. J. Mahmood and  L. B. Y. Aldabbagh
	%D 2013
	%J International Journal of Mechanical and Mechatronics Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 78, 2013
	%T Double Pass Solar Air Heater with Transvers Fins and without Absorber Plate
	%U https://publications.waset.org/pdf/8230
	%V 78
	%X The counter flow solar air heaters, with four
transverse fins and wire mesh layers are constructed and investigated
experimentally for thermal efficiency at a geographic location of
Cyprus in the city of Famagusta. The absorber plate is replaced by
sixteen steel wire mesh layers, 0.18 x 0.18cm in cross section
opening and a 0.02cm in diameter. The wire mesh layers arranged in
three groups, first and second include 6 layers, while the third include
4 layers. All layers fixed in the duct parallel to the glazing and each
group separated from the others by wood frame thickness of 0.5cm to
reduce the pressure drop. The transverse fins arranged in a way to
force the air to flow through the bed like eight letter path with flow
depth 3cm. The proposed design has increased the heat transfer rate,
but on other hand causes a high pressure drop. The obtained results
show that, for air mass flow rate range between 0.011-0.036kg/s, the
thermal efficiency increases with increasing the air mass flow. The
maximum efficiency obtained is 65.6% for the mass flow rate of
0.036kg/s. Moreover, the temperature difference between the outlet
flow and the ambient temperature, ΔT, reduces as the air mass flow
rate increase. The maximum difference between the outlet and
ambient temperature obtained was 43°C for double pass for minimum
mass flow rate of 0.011kg/s. Comparison with a conventional solar
air heater collector shows a significantly development in the thermal
efficiency.
	%P 1293 - 1298