	@article{(Open Science Index):https://publications.waset.org/pdf/4696,
	  title     = {Shunt Power Active Filter Control under NonIdeal Voltages Conditions},
	  author    = {H. Abaali and  M. T. Lamchich and  M. Raoufi},
	  country	= {},
	  institution	= {},
	  abstract     = {In this paper, we propose the Modified Synchronous Detection (MSD) Method for determining the reference compensating currents of the shunt active power filter under non sinusoidal voltages conditions. For controlling the inverter switching we used the PI regulator. The numerical simulation results, using Power System Blockset Toolbox PSB of Matlab, from a complete structure, are presented and discussed.
},
	    journal   = {International Journal of Electrical and Computer Engineering},
	  volume    = {2},
	  number    = {10},
	  year      = {2008},
	  pages     = {2427 - 2432},
	  ee        = {https://publications.waset.org/pdf/4696},
	  url   	= {https://publications.waset.org/vol/22},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 22, 2008},
	}