WASET
	%0 Journal Article
	%A Jung Hyun Kim and  Min Ye Ku and  Gyo Woo Lee
	%D 2012
	%J International Journal of Industrial and Manufacturing Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 72, 2012
	%T Heat Release Performance of Swaged- and Extruded-Type Heat Sink Used in Industrial Inverter
	%U https://publications.waset.org/pdf/1848
	%V 72
	%X In this experiment, we investigated the performance of
two types of heat sink, swaged- and extruded-type, used in the inverter
of industrial electricity generator. The swaged-type heat sink has 62
fins, and the extruded-type has 38 fins having the same dimension as
that of the swaged-type. But the extruded-type heat sink maintains the
same heat transfer area by the laterally waved surface which has 1 mm
in radius. As a result, the swaged- and extruded-type heat sinks
released 71% and 64% of the heat incoming to the heat sink,
respectively. The other incoming heat were naturally convected and
radiated to the ambient. In spite of 40% decrease in number of fins, the
heat release performance of the extruded-type heat sink was lowered
only 7% than that of the swaged-type. We believe that, this shows the
increment of effective heat transfer area by the laterally waved surface
of fins and the better heat transfer property of the extruded-type heat
sink.
	%P 2827 - 2830