WASET
	%0 Journal Article
	%A N. Dizadji and  P. Entezar and  A. Shabani
	%D 2012
	%J International Journal of Mechanical and Industrial Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 61, 2012
	%T Energy Savings in Pumps
	%U https://publications.waset.org/pdf/15410
	%V 61
	%X This study presents energy saving in general-purpose
pumps widely used in industrial applications. Such pumps are
normally driven by a constant-speed electrical motor which in most
applications must support varying load conditions. This is equivalent
to saying the loading conditions mismatch the designed optimal
energy consumption requirements of the intended application thus
resulting in substantial energy losses. In the held experiments it was
indicated that combination of mechanical and electrical speed drives
can contribute to lower energy consumption in the pump without
negatively distorting the required performance indices of a typical
centrifugal pump at substantially lower energy consumption. The
registered energy savings were recorded to be within the 15-40%
margin. It was also indicated that although VSDs are installed at a
cost, the financial burden is balanced against the earnings resulting
from the associated energy savings.
	%P 312 - 315