	  title     = {Calibration Method for an Augmented Reality System},
	  author    = {S. Malek and  N. Zenati-Henda and  M. Belhocine and  S. Benbelkacem},
	  country	= {},
	  institution	= {},
	  abstract     = {In geometrical camera calibration, the objective is to
determine a set of camera parameters that describe the mapping
between 3D references coordinates and 2D image coordinates. In this
paper, a technique of calibration and tracking based on both a least
squares method is presented and a correlation technique developed as
part of an augmented reality system. This approach is fast and it can
be used for a real time system},