%0 Journal Article %A P. Guayjarernpanishkand and T. Mayureesawan %D 2012 %J International Journal of Mathematical and Computational Sciences %B World Academy of Science, Engineering and Technology %I Open Science Index 69, 2012 %T The Comparisons of Average Outgoing Quality Limit between the MCSP-2-C and MCSP-C %U https://publications.waset.org/pdf/14277 %V 69 %X This paper presents a comparison of average outgoing quality limit of the MCSP-2-C plan with MCSP-C when MCSP-2-C has been developed from MCSP-C. The parameters used in MCSP-2- C are: i (the clearance number), c (the acceptance number), m (the number of conforming units to be found before allowing c nonconforming units in the sampling inspection), f1 and f2 (the sampling frequency at level 1 and 2, respectively). The average outgoing quality limit (AOQL) values from two plans were compared and we found that for all sets of i, r, and c values, MCSP-2-C gives higher values than MCSP-C. For all sets of i, r, and c values, the average outgoing quality values of MCSP-C and MCSP-2-C are similar when p is low or high but is difference when p is moderate. %P 1319 - 1322