WASET
	%0 Journal Article
	%A B. Rajesh Kamath and  J. Sundara Rajan
	%D 2008
	%J International Journal of Electrical and Computer Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 18, 2008
	%T Measurement of Small PD-S in Compressed SF6(10%) - N2(90%) Gas Mixture
	%U https://publications.waset.org/pdf/14143
	%V 18
	%X Partial Discharge measurement is a very important
means of assessing the integrity of insulation systems in a High
Voltage apparatus. In compressed gas insulation systems, floating
particles can initiate partial discharge activities which adversely
affect the working of insulation. Partial Discharges below the
inception voltage also plays a crucial in damaging the integrity of
insulation over a period of time. This paper discusses the effect of
loose and fixed Copper and Nichrome wire particles on the PD
characteristics in SF6-N2 (10:90) gas mixtures at a pressure of
0.4MPa. The Partial Discharge statistical parameters and their
correlation to the observed results are discussed.
	%P 1069 - 1072