	  title     = {Cryogenic Freezing Process Optimization Based On Desirability Function on the Path of Steepest Ascent},
	  author    = {R. Uporn and  P. Luangpaiboon},
	  country	= {},
	  institution	= {},
	  abstract     = {This paper presents a comparative study of statistical methods for the multi-response surface optimization of a cryogenic freezing process. Taguchi design and analysis and steepest ascent methods based on the desirability function were conducted to ascertain the influential factors of a cryogenic freezing process and their optimal levels. The more preferable levels of the set point, exhaust fan speed, retention time and flow direction are set at -90oC, 20 Hz, 18 minutes and Counter Current, respectively. The overall desirability level is 0.7044.
},
	    journal   = {International Journal of Industrial and Manufacturing Engineering},
	  volume    = {6},
	  number    = {12},
	  year      = {2012},
	  pages     = {2808 - 2813},
	  ee        = {https://publications.waset.org/pdf/1150},
	  url   	= {https://publications.waset.org/vol/72},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 72, 2012},
	}