	  title     = {Hexavalent Chromium Pollution Abatement by use of Scrap Iron},
	  author    = {Marius Gheju and  Laura Cocheci},
	  country	= {},
	  institution	= {},
	  abstract     = {In this study, the reduction of Cr(VI) by use of scrap
iron, a cheap and locally available industrial waste, was investigated
in continuous system. The greater scrap iron efficiency observed for
the first two sections of the column filling indicate that most of the
reduction process was carried out in the bottom half of the column
filling. This was ascribed to a constant decrease of Cr(VI)
concentration inside the filling, as the water front passes from the
bottom to the top end of the column. While the bottom section of the
column filling was heavily passivated with secondary mineral phases,
the top section was less affected by the passivation process; therefore
the column filling would likely ensure the reduction of Cr(VI) for
time periods longer than 216 hours. The experimental results indicate
that fixed beds columns packed with scrap iron could be successfully
used for the first step of Cr(VI) polluted wastewater treatment.
However, the mass of scrap iron filling should be carefully estimated
since it significantly affects the Cr(VI) reduction efficiency.},
	    journal   = {International Journal of Environmental and Ecological Engineering},
	  volume    = {5},
	  number    = {7},
	  year      = {2011},
	  pages     = {391 - 396},
	  ee        = {https://publications.waset.org/pdf/11025},
	  url   	= {https://publications.waset.org/vol/55},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 55, 2011},
	}