Implementation of a Monostatic Microwave Imaging System Using an Ultra-Wideband Vivaldi Antenna
Authors: Babatunde Olatujoye, Binbin Yang
Abstract:
Microwave imaging is a portable, noninvasive, and non-ionizing imaging technique that employs low-power microwave signals to reveal objects in the microwave frequency range. This technique has immense potential for adoption in commercial and scientific applications such as security scanning, material characterization, and nondestructive testing. This work presents a monostatic microwave imaging setup using an Ultra-Wideband (UWB), low-cost, miniaturized Vivaldi antenna with a bandwidth of 1-6 GHz. The backscattered signals (S-parameters) of the Vivaldi antenna used for scanning targets were measured in the lab using a vector network analyzer (VNA). An automated two-dimensional (2D) scanner was employed for the 2D movement of the transceiver to collect the measured scattering data from different positions. The targets consist of four metallic objects, each with a distinct shape. A similar setup was also simulated in Ansys HFSS. A high-resolution Back Propagation Algorithm (BPA) was applied to both the simulated and experimental backscattered signals. The BPA utilizes the phase and amplitude information recorded over a 2D aperture of 50 cm x 50 cm with a discreet step size of 2 cm to reconstruct a focused image of the targets. The adoption of BPA was demonstrated by coherently resolving and reconstructing reflection signals from conventional time-of-flight profiles. For both the simulation and experimental data, BPA accurately reconstructed a high-resolution 2D image of the targets in terms of shape and location. An improvement of the BPA, in terms of target resolution, was achieved by applying the filtering method in the frequency domain.
Keywords: Backpropagation, microwave imaging, monostatic setup, Vivaldi antenna, ultra-wideband.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 52References:
[1] S. S. Ahmed, A. Schiessl, F. Gumbmann, M. Tiebout, S. Methfessel, and L. P. Schmidt, “Advanced microwave imaging,” IEEE Microw. Mag., vol. 13, no. 6, pp. 8–10, 2012, doi: 10.1109/MMM.2012.2205772.
[2] N. Khalid, M. Zubair, M. Q. Mehmood, and Y. Massoud, “Emerging paradigms in microwave imaging technology for biomedical applications: unleashing the power of artificial intelligence,” npj Imaging, vol. 2, no. 1, pp. 1–20, 2024, doi: 10.1038/s44303-024-00012-8.
[3] I. A. N. Alsbou, K. Cisse, C. Cox, M. Akinbola, “Medical Imaging System Design using Microwave Antennas and Portable Platform,” 2023 IEEE 17th Int. Symp. Med. Inf. Commun. Technol. (ISMICT), Lincoln, NE, USA, pp. 1–5, 2023.
[4] A. V. Muppala, A. Y. Nashashibi, E. Afshari, and K. Sarabandi, “Fast-Fourier Time-Domain SAR Reconstruction for Millimeter-Wave FMCW 3-D Imaging,” IEEE Trans. Microw. Theory Tech., pp. 1–11, 2024, doi: 10.1109/TMTT.2024.3406938.
[5] D. M. Sheen, D. L. McMakin, and T. E. Hall, “Three-dimensional millimeter-wave imaging for concealed weapon detection,” IEEE Trans. Microw. Theory Tech., vol. 49, no. 9, pp. 1581–1592, 2001, doi: 10.1109/22.942570.
[6] M. Dehmollaian, M. Thiel, and K. Sarabandi, “Through-the-wall imaging using differential SAR,” IEEE Trans. Geosci. Remote Sens., vol. 47, no. 5, pp. 1289–1296, 2009, doi: 10.1109/TGRS.2008.2010052.
[7] S. Pisa, E. Piuzzi, E. Pittella, P. D’Atanasio, A. Zambotti, and G. Sacco, “Comparison between delay and sum and range migration algorithms for image reconstruction in through-the-wall radar imaging systems,” IEEE J. Electromagn. RF Microwaves Med. Biol., vol. 2, no. 4, pp. 270–276, 2018, doi: 10.1109/JERM.2018.2878070.
[8] J. Camacho, L. Svilainis, and T. G. Álvarez-Arenas, “Ultrasonic Imaging and Sensors,” Sensors, vol. 22, no. 20, pp. 1–7, 2022, doi: 10.3390/s22207911.
[9] B. Parr, M. Legg, S. Bradley, and F. Alam, “Occluded grape cluster detection and vine canopy visualization using an ultrasonic phased array,” Sensors, vol. 21, no. 6, pp. 1–20, 2021, doi: 10.3390/s21062182.
[10] M. E. Yanik and M. Torlak, “Near-Field MIMO-SAR Millimeter-Wave Imaging with Sparsely Sampled Aperture Data,” IEEE Access, vol. 7, pp. 31801–31819, 2019, doi: 10.1109/ACCESS.2019.2902859.
[11] M. Pastorino and A. Randazzo, “Microwave Imaging Methods and Applications,” Artech, 2018.
[12] A. M. Qashlan, R. W. Aldhaheri, and K. H. Alharbi, “A Modified Compact Flexible Vivaldi Antenna Array Design for Microwave Breast Cancer Detection,” Appl. Sci., vol. 12, no. 10, 2022, doi: 10.3390/app12104908.
[13] C. Lv et al., “Levenberg-marquardt backpropagation training of multilayer neural networks for state estimation of a safety-critical cyber-physical system,” IEEE Trans. Ind. Informatics, vol. 14, no. 8, pp. 3436–3446, 2018, doi: 10.1109/TII.2017.2777460.
[14] T. Bortfeld, J. Bürkelbach, R. Boesecke, and W. Schlegel, “Methods of image reconstruction from projections applied to conformation radiotherapy,” Phys. Med. Biol., vol. 35, no. 10, pp. 1423–1434, 1990, doi: 10.1088/0031-9155/35/10/007.
[15] I. N. Bankman, Ed., Handbook of Medical Image Processing and Analysis, Second. Massachusetts, USA: Academic Press, 2009.
[16] K. Lalitha, J. Manjula, and Rahul Krishnan, “Design Of Uwb Vivaldi Antenna For Stroke Detection And Monitoring Based on Qualitative Microwave Imaging Technique,” Elem. Educ. Online, vol. 20, no. 1, pp. 2335–2341, 2021, doi: 10.17051/ilkonline.2021.01.260.
[17] R. Vehmas and N. Neuberger, “Inverse Synthetic Aperture Radar Imaging: A Historical Perspective and State-of-the-Art Survey,” IEEE Access, vol. 9, pp. 113917–113943, 2021, doi: 10.1109/ACCESS.2021.3104799.
[18] Y. Alvarez López and F. Las-Heras Andrés, “Improved Methods for Fourier-Based Microwave Imaging,” Sensors, vol. 23, no. 22, 2023, doi: 10.3390/s23229250.
[19] S. Paul, R. Chugh, and M. J. Akhtar, “Microwave synthetic aperture radar imaging using SFCW System for buried object detection and security applications,” 2019 IEEE MTT-S Int. Microw. RF Conf. IMARC 2019, pp. 14–17, 2019, doi: 10.1109/IMaRC45935.2019.9118706.
[20] A. V. Diebold, L. Pulido-Mancera, T. Sleasman, M. Boyarsky, M. F. Imani, and D. R. Smith, “Generalized range migration algorithm for synthetic aperture radar image reconstruction of metasurface antenna measurements,” J. Opt. Soc. Am. B, vol. 34, no. 12, p. 2610, 2017, doi: 10.1364/josab.34.002610.
[21] S. V. S. G. Devi, K. Gunasekaran, M. R. Narayanan, A. Kanchana, and G. Nalinipriya, “Enhancement of Image Processing based on Deep Learning Backpropagation Approach,” Int. J. Intell. Syst. Appl. Eng., vol. 12, no. 9s, pp. 32–38, 2024.
[22] M. Samsuzzaman, M. T. Islam, M. T. Islam, A. A. S. Shovon, R. I. Faruque, and N. Misran, “A 16-modified antipodal Vivaldi antenna array for microwave-based breast tumor imaging applications,” Microw. Opt. Technol. Lett., vol. 61, no. 9, pp. 2110–2118, 2019, doi: 10.1002/mop.31873.
[23] D. M. Sheen and T. E. Hall, “Reconstruction techniques for sparse multistatic linear array microwave imaging,” Passiv. Act. Millimeter-Wave Imaging XVII, vol. 9078, p. 90780I, 2014, doi: 10.1117/12.2053814.
[24] N. Hammouch, A. Rghioui, H. Ammor, M. Oubrek, and J. Lloret, A low-cost UWB microwave imaging system for early-stage breast cancer detection, no. 0123456789. Springer US, 2024. doi: 10.1007/s11042-024-19761-0.
[25] T. Spreng, U. Prechtel, B. Schonlinner, V. Ziegler, A. Meusling, and U. Siart, “UWB near-field MIMO radar: Calibration, measurements and image reconstruction,” Eur. Microw. Week 2013, EuMW 2013 - Conf. Proceedings; EuRAD 2013 10th Eur. Radar Conf., pp. 33–36, 2013.
[26] M. Fallahpour, J. T. Case, M. T. Ghasr, and R. Zoughi, “Piecewise and wiener filter-based sar techniques for monostatic microwave imaging of layered structures,” IEEE Trans. Antennas Propag., vol. 62, no. 1, pp. 282–294, 2014, doi: 10.1109/TAP.2013.2287024.