TY - JFULL AU - Samad Jafarmadar and Amin Habibzadeh PY - 2017/8/ TI - Applying Different Working Fluids in a Combined Power and Ejector Refrigeration Cycle with Low Temperature Heat Sources T2 - International Journal of Energy and Power Engineering SP - 848 EP - 854 VL - 11 SN - 1307-6892 UR - https://publications.waset.org/pdf/10007538 PU - World Academy of Science, Engineering and Technology NX - Open Science Index 127, 2017 N2 - A power and cooling cycle, which combines the organic Rankine cycle and the ejector refrigeration cycle supplied by waste heat energy sources, is discussed in this paper. 13 working fluids including wet, dry, and isentropic fluids are studied in order to find their performances on the combined cycle. Various operating conditions’ effects on the proposed cycle are examined by fixing power/refrigeration ratio. According to the results, dry and isentropic fluids have better performance compared with wet fluids. ER -