Abstract:

Open ground storey with floating columns is a typical feature in the modern multistory constructions in urban India. Such features are very much undesirable in buildings built in seismically active areas. The present study proposes a feasible solution to mitigate the effects caused due to non-uniformity of stiffness and discontinuity in load path and to simultaneously hold the functional use of the open storey particularly under the floating column, through a combination of various lateral strengthening systems. An investigation is performed on an example building with nine different analytical models to bring out the importance of recognising the presence of open ground storey and floating columns. Two separate analyses on various models of the building namely, the equivalent static analysis and the response spectrum analysis as per IS: 1893-2002 were performed. Various measures such as incorporation of Chevron bracings and shear walls, strengthening the columns in the open ground storey, and their different combinations were examined. The analysis shows that, in comparison to two short ones separated by interconnecting beams, the structural walls are most effective when placed at the periphery of the buildings and used as one long structural wall. Further, it can be shown that the force transfer from floating columns becomes less horizontal when the Chevron Bracings are placed just below them, thereby reducing the shear forces in the beams on which the floating column rests.

Keywords: Equivalent static analysis, floating column, open ground storey, response spectrum analysis, shear wall, stiffness irregularity.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1127488

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1466

References:


[1] A. Vijayakumar, D. VenkateshBabu, “A survey of methods and techniques used for Seismic retrofitting of RC buildings”,International Journal of Civil and Structural Engineering, vol. 2, no. 1, 2011.
[2] A. Colunga, “Review of the Soft First Story Irregularity Condition of Buildings forSeismic Design”, The Open Civil Engineering Journal, vol. 4, pp. 1-15, 2010.
[3] S. Anbarasu, K.Tamilvanan, “Seismic Retrofitting of Reinforced Concrete Frame Building with Soft Storey”, International Journal of Innovative Research in Science, Engineering and Technology, vol. 5, issue 3, March 2016.
[4] S. Arunkumar, G. Devi, “Seismic Demand Study of Soft Storey Building and its Strengthening for Seismic Resistance”, International Journal of Emerging Trends & Technology in Computer Science (IJETTCS), vol. 5, issue 2, 2016.
[5] A. S. Zubair, K.V. Ramana, Kumar, R. Pradeep, “Seismic Response of RC Frame Structure with Soft Storey”, International Journal of Research in Engineering and Technology, vol. 3, issue 09 Sep 2014.
[6] S. Zambad, V. G. Meshram, “Critical Study on Various Methods of Seismic up Gradation of Building”, International Journal of Science Technology & Engineering, vol. 2, issue 9, March 2016.
[7] P. Philip, C. Madheswaran, E. Skaria, “Study on the Effect of Retrofitting of a Seismically Damaged Building with X-Plate Damper and Geopolymer Concrete”, International Journal of Emerging Technology and Advanced Engineering, vol. 4, issue 9, September 2014.
[8] J. Arlekar, S. Jain, C. Murty, “Seismic Response of RC Frame Buildings with Soft First Storeys”, Proceedings of the CBRI Golden Jubilee Conference on Natural Hazards in Urban Habitat, 1997, New Delhi.
[9] S. Setia, V. Sharma, “Seismic Response ofR.C.C Building with Soft Storey”, International Journal of Applied Engineering Research, vol.7 no.11, 2012.
[10] P.B. Lamb, R.S. Londhe, “Seismic Behaviour of Soft First Storey”, IOSR Journal of Mechanical and Civil Engineering (IOSRJMCE), vol. 4, issue 5, pp 28-33, Nov. - Dec. 2012.
[11] A. Ranganadhan, A. Paul, “Seismic Retrofitting of an Existing Structure”, International Journal of Research in Engineering and Technology, vol. 4, issue 3, April 2015.
[12] S. Sabari, J. Praveen, “Seismic Analysis of Multistorey Building with Floating Column”, International Journal of Civil and Structural Engineering Research, vol. 2, issue 2, pp. 12-23, October 2014-March 2015.
[13] B. Sontakke, A. Moon, “Seismic behaviour of soft storey RC building during earthquake”, International Journal on Recent and Innovation Trends in Computing and Communication, vol. 3, issue 2, February 2015.
[14] M. Mishra, S. Dubey, “Seismic Drift control in soft storied RCC buildings: A Critical Review”, International Journal of Engineering and Technical Research (IJETR), vol. 3, issue 8, August 2015.
[15] B. Harne, R. Shinde, “Review on Seismic Performance of Multi-Storied RC Building with Soft Storey”, International Journal of Research in Engineering and Technology, vol. 4, issue 5, May 2015.
[16] D. Dohare, S. Maru, “Seismic Behavior of soft StoreyBuilding: A Critical Review”, International Journal of Engineering Research and General Science, vol. 2, issue 6, 2014.
[17] S. Udhav, A.N. Shaikh, G. Ravi, “Analysis of Multistorey Building with Floating Column”, International Journal of Engineering Research, vol. 4, no. 9, pp. 475-478, 2015.
[18] P. Agarwal, S. Thakkar, R. Dubey, “Seismic Performance of Reinforced Concrete Buildings During Bhuj Earthquake of 26 January 2001”, ISET Journal of Earthquake Technology, paper no. 424, vol. 39, no.3, pp. 195-217, September 2002.
[19] P. Prasad, T. Sekhar, “Study Of Behaviour Of Seismic Analysis Of Multi Storied Building With And Without Floating Column”, Caribbean Journal of Science and Technology, vol. 2, pp. 697-710, 2014.
[20] N. Agrawal, P. Kulkarni, “Static Analysis of Masonry Infilled R. C. Frame With &Without Opening Including Soft Storey of Symmetric Building”, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), vol. 8, issue 1, pp. 78-87, 2013.
[21] IS:1893-2002, “The Criteria for Earthquake Resistant Design of Structures”, Part 1: General Provisions and Buildings, Bureau of Indian Standards.
[22] STAAD. Pro Version 2007 Build 04 Proprietary Program of Research Engineers International, by Bentley Systems.