	  title     = {Tactile Sensory Digit Feedback for Cochlear Implant Electrode Insertion},
	  author    = {Yusuf Bulale and  Mark Prince and  Geoff Tansley and  Peter Brett},
	  country	= {},
	  institution	= {},
	  abstract     = {Cochlear Implantation (CI) which became a routine
procedure for the last decades is an electronic device that provides a
sense of sound for patients who are severely and profoundly deaf.
The optimal success of this implantation depends on the electrode
technology and deep insertion techniques. However, this manual
insertion procedure may cause mechanical trauma which can lead to
severe destruction of the delicate intracochlear structure.
Accordingly, future improvement of the cochlear electrode implant
insertion needs reduction of the excessive force application during
the cochlear implantation which causes tissue damage and trauma.
This study is examined tool-tissue interaction of large prototype scale
digit embedded with distributive tactile sensor based upon cochlear
electrode and large prototype scale cochlea phantom for simulating
the human cochlear which could lead to small scale digit
requirements. The digit, distributive tactile sensors embedded with
silicon-substrate was inserted into the cochlea phantom to measure
any digit/phantom interaction and position of the digit in order to
minimize tissue and trauma damage during the electrode cochlear
insertion. The digit have provided tactile information from the digitphantom
insertion interaction such as contact status, tip penetration,
obstacles, relative shape and location, contact orientation and
multiple contacts. The tests demonstrated that even devices of such a
relative simple design with low cost have potential to improve
cochlear implant surgery and other lumen mapping applications by
providing tactile sensory feedback information and thus controlling
the insertion through sensing and control of the tip of the implant
during the insertion. In that approach, the surgeon could minimize the
tissue damage and potential damage to the delicate structures within
the cochlear caused by current manual electrode insertion of the
cochlear implantation. This approach also can be applied to other
minimally invasive surgery applications as well as diagnosis and path
navigation procedures.},
	    journal   = {International Journal of Biomedical and Biological Engineering},
	  volume    = {9},
	  number    = {12},
	  year      = {2015},
	  pages     = {857 - 863},
	  ee        = {https://publications.waset.org/pdf/10003244},
	  url   	= {https://publications.waset.org/vol/108},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 108, 2015},
	}