Experimental Behavior of Composite Shear Walls Having L Shape Steel Sections in Boundary Regions
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
Experimental Behavior of Composite Shear Walls Having L Shape Steel Sections in Boundary Regions

Authors: S. Bahadır Yüksel, Alptuğ Ünal

Abstract:

The Composite Shear Walls (CSW) with steel encased profiles can be used as lateral-load resisting systems for buildings that require considerable large lateral-load capacity. The aim of this work is to propose the experimental work conducted on CSW having L section folded plate (L shape steel made-up sections) as longitudinal reinforcement in boundary regions. The study in this paper present the experimental test conducted on CSW having L section folded plate as longitudinal reinforcement in boundary regions. The tested 1/3 geometric scaled CSW has aspect ratio of 3.2. L-shape structural steel materials with 2L-19x57x7mm dimensions were placed in shear wall boundary zones. The seismic behavior of CSW test specimen was investigated by evaluating and interpreting the hysteresis curves, envelope curves, rigidity and consumed energy graphs of this tested element. In addition to this, the experimental results, deformation and cracking patterns were evaluated, interpreted and suggestions of the design recommendations were proposed.

Keywords: Shear wall, composite shear wall, boundary reinforcement, earthquake resistant structural design, L section.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1108058

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1766

References:


[1] S. B. Yüksel, "Innovation for the Horizontal and Vertical Reinforcements Of Columns And Structural Walls In Buildings," Patent Application Wo/2014/126544. 2014, Publication Date: 21.08.2014.
[2] S. B. Yüksel, "Yapılarda Kolonlar ve Perde Duvarlar Đçin Düsey ve Yatay Donatılarda Yenilik," Selcuk University TTO Patent Project Market, Dedeman Hotel, Konya, 19-20 November 2014. Patent and Project Poster Manuscript Book-1. 2014, pp. 119
[3] Q. Zhao and A. Astaneh-Asl, "Cyclic behavior of traditional and innovative composite shear walls. J. Struct. Eng. 2004, vol.130, pp. 271−284.
[4] D. Dan, A. Fabian, V. Stoian, "Nonlinear behavior of composite shear walls with vertical steel encased profiles," Engineering Structures, 2011, vol.33, pp. 2794−2804.
[5] D. Dan, A. Fabian, V. Stoian, "Theoretical and experimental study on composite steel–concrete shear walls with vertical steel encased profiles," Journal of Constructional Steel Research, 2011, vol. 67, pp. 800−813.
[6] D. Dan, "Experimental tests on seismically damaged composite steel concrete walls retrofitted with CFRP composites," Engineering Structures, 2012, vol.45, pp. 338−348.
[7] F. Liao, L. Han and Z. Tao, "Performance of reinforced concrete shear walls with steel reinforced concrete boundary columns," Engineering Structures, 2012, vol. 44, pp. 186 - 209.
[8] J. Qian, Z. Jiang and X. Ji, "Behavior of steel tube-reinforced concrete composite walls subjected to high axial force and cyclic loading," Engineering Structures, 2012, vol. 36, pp. 173−184.