Abstract:

The number of persons with implanted cardiac pacemakers (PM) has increased in Western countries. The aim of this paper is to investigate the possible situations where persons with a PM may be exposed to extremely low frequency (ELF) electric (EF) and magnetic fields (MF) that may disturb their PM. Based on our earlier studies, it is possible to find such high public exposure to EFs only in some places near 400 kV power lines, where an EF may disturb a PM in unipolar mode. Such EFs cannot be found near 110 kV power lines. Disturbing MFs can be found near welding machines. However, we do not have measurement data from welding. Based on literature and earlier studies at Tampere University of Technology, it is difficult to find public EF or MF exposure that is high enough to interfere with PMs.

Keywords: Cardiac Pacemaker, Electric Field, Magnetic Field.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1100683

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2489

References:


[1] G. Chiara, V. Primiani, and F. Moglie, “Experimental and numeric investigation about electromagnetic interference between implantable cardiac pacemaker and magnetic fields at power line frequency,” Ann. Ist. Super Sanita, vol. 43, no. 3, pp. 248–253,2007.
[2] D. Marco, G. Eisinger, and D. L. Hayes, “Testing of work environments for electromagnetic interference,” Pacing Clin. Electrophysiol., vol. 15, pp. 2016–2022, 1992.
[3] M. Hirose, M. Hida, E. Sato, K. Kokubo, M. Nie, and H. Kobayashi, “Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven,” Pacing Clin. Electrophysiol., vol. 28, pp. 540–548, 2005.
[4] A. Trigano, P. Deloy, O. Blandeau, and S. Levy, “Arc welding interference recorded by an implanted cardiac pacemaker,” Int. J. Cardiol., vol. 109, pp. 132–134, 2006.
[5] S. Lee, K. Fu, T. Kohno, B. Ransford, W. H. Maisel, “Clinically significant magnetic interference of implanted cardiac devices by portable headphones,” Heart Rhythm, vol. 6, pp. 1432–1436, 2009.
[6] M. Souques, I. Magne, and J. Lambrozo, “Implantable cardioverter defibrillator and 50-Hz electric and magnetic fields exposure in the workplace,” Int. Arch. Occup. Environ. Health, vol. 84, pp. 1–6, 2011.
[7] M. Tiikkaja, A. L. Aro, T. Alanko, H. Lindholm, H. Sistonen, J. E. K. Hartikainen, L. Toivonen, J. Juutilainen, and M. Hietanen, “Electromagnetic interference with cardiac pacemakers and implantable cardioverter-defibrillators from low frequency electromagnetic fields in vivo,” Europace, vol. 15, pp. 388–394, 2013.
[8] L. Korpinen, H. Kuisti, J. Elovaara, and V. Virtanen, “Cardiac pacemakers in electric and magnetic fields of 400-kV power lines,” Pacing Clin. Electrophysiol., vol. 35, pp. 422–430, 2012.
[9] L. Korpinen, H. Kuisti, J. Elovaara, V. Virtanen, “Response,” Pacing Clin. Electrophysiol., vol. 36, no. 2, pp. 267–268, 2013.
[10] L. Korpinen, H. Kuisti, J. Elovaara, and V. Virtanen, “implantable cardioverter defibrillators in electric and magnetic fields of 400 kV power lines,” Pacing Clin. Electrophysiol., vol. 37, pp. 297–303, 2014.
[11] J. Katrib, M. Nadi, D. Kourtiche, I. Magne, P. Schmitt, M. Souques, P. Roth, “In vitro assessment of the immunity of implantable cardioverterdefibrillators to magnetic fields of 50/60 Hz,” Physiol. Meas., vol. 34, no. 10, pp. 1281–1292, 2013.
[12] CENELEC – European Committee for Electrotechnical Standardization, 2010. Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices – Part 1: General. Brussels, Belgium.
[13] CENELEC – European Committee for Electrotechnical Standardization, 2011. Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices – Part 2-1: Specific assessment for workers with cardiac pacemakers. Brussels, Belgium.
[14] STM (Ministry of Social Affairs and Health in Finland), 2002. Decree on the limitation of public exposure to non-ionizing radiation (294/2002). Helsinki, 47 p. (In Finnish).
[15] J. Elovaara, H. Kuisti, and L. Korpinen, 2009, “Workers exposure to electric fields in 400 kV substation and overhead line works,” in 2009 Proc. International Colloquium Power Frequency Electromagnetic Fields ELF EMF, 3–4 June 2009, Sarajevo, Bosnia and Herzegovina, Committee for Bosnia and Herzegovina and CIGRE SCs, B2 – Overhead Lines, B1 – Insulated Cables, B3 – Substations, B4 – HVDC and Power Electronics, C3 – System Environmental Performance and C4 – System Technical Performance, paper 15, 8 p.
[16] R. Lehtelä, T. Laurila, L. Österholm, and L. Korpinen, “Magnetic field exposure of 110 kV underground power cables,” in 2009 Proc. BIOEM 2009, June 14-19, 2009, Davos, Switzerland, 2 p.
[17] T. Keikko, “Technical management of the electric and magnetic fields in electric power system,” Doctoral dissertation, Tampere University of Technology, 422.
[18] F. Gobba, R. Pääkkönen, H. Tarao, and L. Korpinen, “The possible exposure of children to extremely low frequency magnetic fields in the home,” in 2012 Moscow Proc. PIERS, pp. 2012, Moscow proceedings, August 19–23, 2012, Moscow, Russia. Progress in Electromagnetics research symposium 286–288.
[19] R. Pääkkönen, M. Lundström, J, Mustaparta, L. Korpinen, “Preliminary measurements of smart meter electromagnetic field (50-100 kHz) emissions in Finland” 8th International Workshop on Biological Effects of Electromagnetic Fields. 21st -25th September 2014, Varna, Bulgaria
[20] R. Pääkkönen, M. Lundström, J, Mustaparta, L. Korpinen, ”Examples of electromagnetic field (50–100 kHz) emissions from smart meters in Finland” Radioprotection, (in press)
[21] R. Pääkkönen, L. Korpinen, Emission of smart meter electromagnetic field (50–100 kHz) in Finland, CIRED2015- 23rd International Conference on Electricity Distribution, Lyon, 15-18 June 2015 (accepted)
[22] R. Pääkkönen, M. Lundström, J, Mustaparta, L. Korpinen, “Exposure to RF fields during the remote readings of the smart meter in Finland”, 8th International Workshop on Biological Effects of Electromagnetic Fields. 21st -25th September 2014, Varna, Bulgaria
[23] L. Korpinen, A. Lähdetie, Å. Amundin, H. Piippo, L. Sydänheimo, “Example measurements of exposure to ELF magnetic fields on the metro station in Finland”, 8th International Workshop on Biological Effects of Electromagnetic Fields. 21st -25th September 2014, Varna, Bulgaria
[24] A. Trigano, O. Blandeau, M. Souques, J. P. Gernez, and I. Magne, “Clinical study of interferences with cardiac pacemakers by a magnetic field at power-line frequency,” J. Am. Coll. Cadiol., vol. 45, pp. 896– 900, 2005.