Buckling Performance of Irregular Section Cold-Formed Steel Columns under Axially Concentric Loading
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
Buckling Performance of Irregular Section Cold-Formed Steel Columns under Axially Concentric Loading

Authors: Chayanon Hansapinyo

Abstract:

This paper presents experimental investigation and finite element analysis on buckling behavior of irregular section coldformed steel columns under axially concentric loading. For the experimental study, four different sections of columns were tested to investigate effect of stiffening and width-to-thickness ratio on buckling behavior. For each of the section, three lengths of 230, 950 and 1900 mm. were studied representing short, intermediate long and long columns, respectively. Then, nonlinear finite element analyses of the tested columns were performed. The comparisons in terms of load-deformation response and buckling mode show good agreement and hence the FEM models were validated. Parametric study of stiffening element and thickness of 1.0, 1.15, 1.2, 1.5, 1.6 and 2.0 mm. was analyzed. The test results showed that stiffening effect pays a large contribution to prevent distortional mode. The increase in wall thickness enhanced buckling stress beyond the yielding strength in short and intermediate columns, but not for the long columns.

Keywords: Buckling behavior, Irregular section, Cold-formed steel, Concentric loading.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1338238

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2486

References:


[1] Young, B. and Chen, J. (2008). “Column Tests of Cold-formed Steel non Symmetric Lipped Angle Section”, Journal of Constructional Steel Research, 64: 808-815.
[2] Narayanan, S. and Mahendran, M. (2003). “Ultimate capacity of innovation cold-formed steel columns”, Journal of constructional steel research, 59: 480-508.
[3] Standards Australia. (1996). Australian/ New Zealand Standard AS/NZS4600. Cold formed steel structures. Sydney.
[4] Ellobody, E. (2007). “Buckling analysis of high strength stainless steel stiffened and unstiffened slender hollow section columns”, Journal of Constructional Steel Research, 63: 145-155.
[5] American Iron and Steel Institute. (2001). North American Specification for the Design of Cold-Formed Steel Structure Member. Washington, DC : American Iron and Steel Institute
[6] AS/NZS. Cold-formed stainless steel structures. Australian/New Zealand Standard, AS/NZS 4673:2001. Sydney (Australia): Standards Australia; 2001.
[7] EC3. Eurocode 3: Design of steel structures — Part 1.4: General rules — Supplementary rules for stainless steels. European Committee for Standardization, ENV 1993-1-4. Brussels: CEN; 1996.
[8] Freitas, A.M.S., Freites, M.S.R and Souza, F. T. (2005). “Analysis of steel storage rack columns”, Journal of Constructional Steel Research, 61: 1135-1146.
[9] Nawikkawanit, O. and Hansapinyo, C. (2010) “Dynamic Behavior of Electronic Cabinet” Third International Conference on Geoinformation Technology for Natural Disaster Management & Rehabilitation, GIT4NDM 2010, October 19-20, 2010, Chiang Mai, Thailand.