Structural Assessment of Low-rise Reinforced Concrete Frames under Tsunami Loads
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32804
Structural Assessment of Low-rise Reinforced Concrete Frames under Tsunami Loads

Authors: Hussain Jiffry, Kypros Pilakoutas, Reyes Garcia

Abstract:

This study examines analytically the effect of tsunami loads on reinforced concrete (RC) frame buildings. The impact of tsunami wave loads and waterborne objects are analyzed using a typical substandard full-scale two-story RC frame building tested as part of the EU-funded Ecoleader project. The building was subjected to shake table tests in bare condition, and subsequently strengthened using Carbon Fiber Reinforced Polymers (CFRP) composites and retested. Numerical models of the building in both bare and CFRP-strengthened conditions are calibrated in DRAIN-3DX software to match the test results. To investigate the response of wave loads and impact forces, the numerical models are subjected to nonlinear dynamic analyses using force time-history input records. The analytical results are compared in terms of displacements at the floors and at the “impact point” of a boat. The results show that the roof displacement of the CFRP-strengthened building reduced by 63% when compared to the bare building. The results also indicate that strengthening only the mid-height of the impact column using CFRP is more effective at reducing damage when compared to strengthening other parts of the column. Alternative solutions to mitigate damage due to tsunami loads are suggested.

Keywords: Tsunami loads, hydrodynamic load, impact load, waterborne objects, RC buildings.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1099583

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1897

References:


[1] Post Tsunami Recovery and Reconstruction, Joint report of government of Sri Lanka and Development partners (December 2005).
[2] Renuka, I. H. S., and C. S. Lewangamage. (2011) Structural Aspects Of Post Tsunami Domestic Constructions In Sri Lanka. Journal of SLSAJ, Vol 11, 65-71
[3] Nistor, I., Palermo, D., Nouri, Y., Murty, T., and Saatcioglu, M., “Tsunami-Induced Forces on Structures,” Handbook of Coastal and Ocean Engineering, World Scientific, 2009.
[4] Madurapperuma, K. M. (2007). Impact Response of Buildings due to Tsunami Water-Borne Massive Objects. M.Eng. Thesis, Dept. of Civil Engineering, Tokyo Institute of Technology, Tokyo, Japan.
[5] FEMA P646. (2008). Guidelines for Design of Structures for Vertical Evacuation from Tsunamis. Washington, D.C., Federal Emergency Management Agency.
[6] Federal Emergency Management Agency (FEMA). (2000). FEMA coastal construction manual, FEMA 55,Washington, D.C.
[7] Thurairajah A. (2005). Structural design loads for tsunami and floods. International Conference on Disaster Reduction on Coasts, November, Melbourne, Australia.
[8] Yeh H., Robertson I. &Preuss J. (2005). Development of Design Guidelines for Structures that Serve as Tsunami Vertical Evacuation Sites. Washington Division of Geology and Earth Resources, Open file report - 4, November, 2005
[9] Yeh, H. (2007). Design tsunami forces for onshore structures, J of Disaster Research, 2(6), 531-536.
[10] CCH. (2000). Regulations within flood hazard districts and developments adjacent to drainage facilities in the revised ordinances of Honolulu, City and Country of Honolulu Building Code, Department of Planning and Permitting, Honolulu, Hawaii.
[11] Madurapperuma K.M. &Wijeyewickrema A.C. (2008). Nonlinear response of RC buildings due to impact of tsunami water-borne boats and containers. 14th World Conference on Earthquake Engineering, International Association for Earthquake Engineering, October, Beijing, China.
[12] Dias, W.P.S., Bandara, K.M.K. (2012),Tsunami Wave Loading on Buildings: A Simplified Approach, Department of Civil Engineering, University of Moratuwa, Moratuwa, Sri Lanka,
[13] Garcia R, Hajirasouliha I, Pilakoutas K (2010) Seismic behaviour of deficient RC frames strengthened with CFRP composites. EngStruct 32(10), 3075-3085.
[14] Garcia, R., Hajirasouliha, I., Guadagnini, M., Helal, Y., Jemaa, Y., Pilakoutas, K. et al. (2014) Full-scale shaking table tests on a substandard RC building repaired and strengthened with Post-Tensioned Metal Straps. J Earthquake Eng, 18(2), 187-213.