2 Simultaneous Determination of Bisphenol a, Phtalates and Its Metabolites in Human Urine, by Tandem SPE Coupled to GC-MS

Authors: V. F. Domingues, C. Delerue-matos, L. Correia-Sá, S. Norberto, Conceição Calhau

Abstract:

Endocrine disruptor chemicals (EDCs) are synthetic compounds that even though being initially designed for a specific function are now being linked with a wide range of side effects. The list of possible EDCs is growing and includes phthalates and bisphenol A (BPA). Phthalates are one of the most widely used plasticizers to improve the extensibility, elasticity and workability of polyvinyl chloride (PVC), polyvinyl acetates, etc. Considered non-toxic and harmless additives for polymers, they were used unrestrainedly all over the world for several decades. However, recent studies have indicated that some phthalates and their metabolic products are reproductive and developmental toxicants in animals and suspected endocrine disruptors in humans. BPA (2,2-bis(4-hydroxyphenyl)propane) is a high production volume chemical mainly used in the production of polycarbonate plastics and epoxy resins. Although BPA was initially considered to be a weak environmental estrogen, nowadays it is known that this compound can stimulate several cellular responses at very low levels of concentrations. The aim of this study was to develop a method based on tandem SPE to evaluate the presence of phthalates, metabolites and BPA in human urine samples. The analyzed compounds included: dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP), BPA, mono-isobutyl phthalate (MiBP), monobutyl phthalate (MBP) and. mono-(2-ethyl-5-oxohexyl) (MEOHP). Two SPE cartridges were applied both from Phenomenex, the strata X polymeric reversed phase and the strata X A (Strong anion). Chromatographic analyses were carried out in a Thermo GC ULTRA GC-MS/MS. Good recoveries and linear calibration curves were obtained. After validation, the methodology was applied to human urine samples for phthalates, metabolites and BPA evaluation.

Keywords: Metabolites, Gas Chromatography, Bisphenol A (BPA), phtalates, SPE, tandem mode

Procedia PDF Downloads 168
1 Pharmacokinetic Monitoring of Glimepiride and Ilaprazole in Rat Plasma by High Performance Liquid Chromatography with Diode Array Detection

Authors: Anil V. Chandewar, Anil P. Dewani, Alok S. Tripathi

Abstract:

Present manuscript reports the development and validation of a quantitative high performance liquid chromatography method for the pharmacokinetic evaluation of Glimepiride (GLM) and Ilaprazole (ILA) in rat plasma. The plasma samples were involved with Solid phase extraction process (SPE). The analytes were resolved on a Phenomenex C18 column (4.6 mm× 250 mm; 5 µm particle size) using a isocratic elution mode comprising methanol:water (80:20 % v/v) with pH of water modified to 3 using Formic acid, the total run time was 10 min at 225 nm as common wavelength, the flow rate throughout was 1ml/min. The method was validated over the concentration range from 10 to 600 ng/mL for GLM and ILA, in rat plasma. Metformin (MET) was used as Internal Standard. Validation data demonstrated the method to be selective, sensitive, accurate and precise. The limit of detection was 1.54 and 4.08 and limit of quantification was 5.15 and 13.62 for GLM and ILA respectively, the method demonstrated excellent linearity with correlation coefficients (r2) 0.999. The intra and inter-day precision (RSD%) values were < 2.0% for both ILA and GLM. The method was successfully applied in pharmacokinetic studies followed by oral administration in rats.

Keywords: Pharmacokinetics, HPLC, SPE, glimepiride, ilaprazole