	%X This paper presents reliability indices evaluation of the
rotor core magnetization of the induction motor operated as a self
excited induction generator by using probability distribution approach
and Monte Carlo simulation. Parallel capacitors with calculated
minimum capacitive value across the terminals of the induction motor
operated as a SEIG with unregulated shaft speed have been connected
during the experimental study. A three phase, 4 poles, 50Hz, 5.5 hp,
12.3A, 230V induction motor coupled with DC Shunt Motor was
tested in the electrical machine laboratory with variable reactive loads.
Based on this experimental study, it is possible to choose a reliable
induction machines operated as a SEIG for unregulated renewable
energy application in remote area or where grid is not available.
Failure density function, cumulative failure distribution function,
survivor function, hazard model, probability of success and
probability of failure for reliability evaluation of the three phase
induction motor operating as a SEIG have been presented graphically
in this paper.