Close Loop Controlled Current Nerve Locator
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32799
Close Loop Controlled Current Nerve Locator

Authors: H. A. Alzomor, B. K. Ouda, A. M. Eldeib

Abstract:

Successful regional anesthesia depends upon precise location of the peripheral nerve or nerve plexus. Locating peripheral nerves is preferred to be done using nerve stimulation. In order to generate a nerve impulse by electrical means, a minimum threshold stimulus of current “rheobase” must be applied to the nerve. The technique depends on stimulating muscular twitching at a close distance to the nerve without actually touching it. Success rate of this operation depends on the accuracy of current intensity pulses used for stimulation .In this paper, we will discuss a circuit and algorithm for closed loop control for the current, theoretical analysis and test results is discussed and results is compared to previous techniques.

Keywords: Close Loop Control, Constant Current, Nerve Locator.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1089285

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1353

References:


[1] Dr Anand M. Sardesai and Dr Uma Iyer, "Nerve Stimulation for Peripheral Nerve Blockade." ATOTW, 2009, #149 August ,PP 1-8.
[2] D. Jochum , G. Iohom, D. P. Diarra, F. Loughnane, L. J. Dupre and H. Bouaziz, "An Objective assessment of nerve stimulators used for peripheral nerve blockade” Anaesthesia, 2006, 61, PP 557–564.
[3] Phil Dalrymple and Subbiah Chelliah "Electrical Nerve Locators”, British Journal of Anaesthesia, 2006, Volume 6 Number 1, PP 32-36.
[4] Jader A. De Lima and Adriano S. Cordeiro, "A Low-Cost Neurostimulator with Accurate Pulsed-Current Control”, IEEE Transactions on Biomedical Engineering, vol. 49, no. 5, May 2002, pp. 497-500.
[5] K. W. Eric Cheng, Yan Lu, Kai-Yu Tong, A. B. Rad, Daniel H. K. Chow, and Danny Sutanto, "Development of a Circuit for Functional Electrical Stimulation” IEEE Transactions on Neural Systems And Rehabilitation Engineering, vol. 12, No. 1, March 2004 pp 43-47.
[6] Subaryani D H Soedirdjo, Mervin T Hutabarat, "Microcontroller-based Transcutaneous Electrical Nerve Stimulator with 8 Bit Cascade DAC” International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME), 2009 pp1-5.
[7] H. A. Alzomor, B. K. Ouda "Low Cost,Compact and Pulsated Constant Current Microcontroller Based Nerve Locator” Cairo 6th International Biomedical Engineering Conference, Dec. 2012, pp. 87–90.