Pollutant Loads of Urban Runoff from a Mixed Residential-Commercial Catchment

Authors: Carrie Ho, Tan Yee Yong

Abstract:

Urban runoff quality for a mixed residential-commercial land use catchment in Miri, Sarawak was investigated for three storm events in 2011. Samples from the three storm events were tested for five water quality parameters, namely, TSS, COD, BOD5, TP, and Pb. Concentration of the pollutants were found to vary significantly between storms, but were generally influenced by the length of antecedent dry period and the strength of rainfall intensities. Runoff from the study site showed a significant level of pollution for all the parameters investigated. Based on the National Water Quality Standards for Malaysia (NWQS), stormwater quality from the study site was polluted and exceeded class III water for TSS and BOD5, with maximum EMCs of 177 and 24 mg/L, respectively. Design pollutant load based on a design storm of 3-month average recurrence interval (ARI) for TSS, COD, BOD5, TP, and Pb were estimated to be 40, 9.4, 5.4, 1.7, and 0.06 kg/ha, respectively. The design pollutant load for the pollutants can be used to estimate loadings from similar catchments within Miri City.

Keywords: Mixedland-use, urban runoff, pollutant load.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1089281

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2104

References:


[1] A. H. Elliott, and S. A. Trowsdale, "A review of models for low impact urban stormwater drainage,” Environmental Modelling & Software, vol. 22, no. 3, pp. 394-405, 2007.
[2] K. Gupta, and A. J. Saul, "Specific relationships for the first flush load in combined sewer flows,” Water Research, vol. 30, no. 5, pp. 1244-1252, 1996.
[3] C. Zoppou, "Review of urban storm water models,” Environmental Modelling &Software, vol. 16, pp. 195-231, 2001.
[4] J.H. Lee and K.W. Bang, "Characterization of urban stormwater runoff,” Water Research, vol. 34, no. 6, pp. 1773-1780, 2000.
[5] US EPA, "2000 National Water Quality Inventory Report to Congress,” Office of Water, Washington, DC, 2002.
[6] S. M. McLeod, J. A. Kells, and G. J. Putz, "Urban runoff quality characterization and load estimation in Saskatoon, Canada,” Journal of Environmental Engineering, vol. 132, no. 11, pp. 1470-1481, 2006.
[7] Environment Canada, "Threats to sources of drinking water and aquatic ecosystem health in Canada,” NWRI Scientific Assessment Rep. Series No. 1, National Water Research Institute, Burlington, Ontario, Canada, 2001.
[8] V. Novotny, and H. Olem, Water quality: prevention, identification, and management of diffuse pollution. Van Nostrand Reinhold, 1994.
[9] R. Nazahiyah, Z. Yusop, and I. Abustan, "Stormwater quality and pollution loading from an urban residential catchment in Johor, Malaysia,” Water science and technology, vol. 56, no. 7, pp. 1-9, 2007.
[10] Department of Environment Malaysia, "Malaysia Environmental Quality Report 2011,” Ministry of Natural Resources and Environment, Malaysia, 2011.
[11] M.H. Park, X. Swamikannu, and M.K. Stenstrom, "Accuracy and precision of the volume-concentration method for urban stormwater modeling,” Water Research, vol. 43, pp. 2773-2786, 2011.