WASET
	@article{(Open Science Index):https://publications.waset.org/pdf/7887,
	  title     = {Noise Removal from Surface Respiratory EMG Signal},
	  author    = {Slim Yacoub and  Kosai Raoof},
	  country	= {},
	  institution	= {},
	  abstract     = {The aim of this study was to remove the two principal
noises which disturb the surface electromyography signal
(Diaphragm). These signals are the electrocardiogram ECG artefact
and the power line interference artefact. The algorithm proposed
focuses on a new Lean Mean Square (LMS) Widrow adaptive
structure. These structures require a reference signal that is correlated
with the noise contaminating the signal. The noise references are
then extracted : first with a noise reference mathematically
constructed using two different cosine functions; 50Hz (the
fundamental) function and 150Hz (the first harmonic) function for
the power line interference and second with a matching pursuit
technique combined to an LMS structure for the ECG artefact
estimation. The two removal procedures are attained without the use
of supplementary electrodes. These techniques of filtering are
validated on real records of surface diaphragm electromyography
signal. The performance of the proposed methods was compared with
already conducted research results.},
	    journal   = {International Journal of Electronics and Communication Engineering},
	  volume    = {2},
	  number    = {2},
	  year      = {2008},
	  pages     = {266 - 273},
	  ee        = {https://publications.waset.org/pdf/7887},
	  url   	= {https://publications.waset.org/vol/14},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 14, 2008},
	}