WASET
	%0 Journal Article
	%A Samraj Andrews and  Ramaswamy Palaniappan and  Nidal Kamel
	%D 2007
	%J International Journal of Electronics and Communication Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 12, 2007
	%T Extracting Single Trial Visual Evoked Potentials using Selective Eigen-Rate Principal Components
	%U https://publications.waset.org/pdf/7179
	%V 12
	%X In single trial analysis, when using Principal
Component Analysis (PCA) to extract Visual Evoked Potential
(VEP) signals, the selection of principal components (PCs) is an
important issue. We propose a new method here that selects only
the appropriate PCs. We denote the method as selective eigen-rate
(SER). In the method, the VEP is reconstructed based on the rate
of the eigen-values of the PCs. When this technique is applied on
emulated VEP signals added with background
electroencephalogram (EEG), with a focus on extracting the
evoked P3 parameter, it is found to be feasible. The improvement
in signal to noise ratio (SNR) is superior to two other existing
methods of PC selection: Kaiser (KSR) and Residual Power (RP).
Though another PC selection method, Spectral Power Ratio (SPR)
gives a comparable SNR with high noise factors (i.e. EEGs), SER
give more impressive results in such cases. Next, we applied SER
method to real VEP signals to analyse the P3 responses for
matched and non-matched stimuli. The P3 parameters extracted
through our proposed SER method showed higher P3 response for
matched stimulus, which confirms to the existing neuroscience
knowledge. Single trial PCA using KSR and RP methods failed to
indicate any difference for the stimuli.
	%P 1885 - 1888