An Inductive Coupling Based CMOS Wireless Powering Link for Implantable Biomedical Applications
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32807
An Inductive Coupling Based CMOS Wireless Powering Link for Implantable Biomedical Applications

Authors: Lei Yao, Jia Hao Cheong, Rui-Feng Xue, Minkyu Je

Abstract:

A closed-loop controlled wireless power transmission circuit block for implantable biomedical applications is described in this paper. The circuit consists of one front-end rectifier, power management sub-block including bandgap reference and low drop-out regulators (LDOs) as well as transmission power detection / feedback circuits. Simulation result shows that the front-end rectifier achieves 80% power efficiency with 750-mV single-end peak-to-peak input voltage and 1.28-V output voltage under load current of 4 mA. The power management block can supply 1.8mA average load current under 1V consuming only 12μW power, which is equivalent to 99.3% power efficiency. The wireless power transmission block described in this paper achieves a maximum power efficiency of 80%. The wireless power transmission circuit block is designed and implemented using UMC 65-nm CMOS/RF process. It occupies 1 mm × 1.2 mm silicon area.

Keywords: Implantable biomedical devices, wireless power transfer, LDO, rectifier, closed-loop power control

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1061214

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2242

References:


[1] M. A. Lebedev, and M. A. L. Nicolelis, "Brain-machine interfaces: past, present and future", Trends in Neurosciences, vol. 106, no. 24. Pp. 3006-3008.
[2] K. D. Wise, D. J. Anderson, J. F. Hetke, et al., "Wireless implantable microsystems: High-density electronic interfaces to the nervous system", Proceedings of the IEEE, vol. 92, no. 1, pp. 76-97.
[3] A. A. Sodagar, K. D. Wise, K. Najafi, "A fully integrated mixed-signal neural processor for implantable multichannel cortical recording," IEEE Trans. Biomed. Eng., vol. 54, no. 6, pp. 1075-1088, Jun 2007.
[4] F. Graichen, R. Arnold, A. Rohlmann, et al., "Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants," IEEE Trans. Biomed. Eng., vol. 54, no. 2, pp. 253-261, Feb 2007.
[5] K. D. Wise and K. Najafi, "Fully-implantable auditory prostheses: Restoring hearing to the profoundly deaf," in IEEE International Electron Devices Meeting, pp. 499-502, Dec 2002.
[6] Q. Y. Cai, K. F. Zeng, C. M. Ruan, et al., "A wireless, remote query glucose biosensor based on a pH-sensitive polymer", Analytical Chemistry, vol. 76, no. 14, pp. 4038-4043, Jul 2004.
[7] K. H. Lee, C. D. Blaha, P. A. Garris, et al., "Evolution of Deep Brain Stimulation: Human Electrometer and Smart Devices Supporting the Next Generation of Therapy," Neuromodulation, vol. 12, no. 2, pp. 85-103, Apr 2009.
[8] T. Ativanichiayaphong, J. W. He, C. E. Hagains, et al., "A combined wireless neural stimulating and recording system for study of pain processing," Journal of Neuroscience Methods, vol. 170, no 1, pp. 25-34, May 2008.
[9] M. Ortmanns, A. Rocke, M. Gehrke, et al., "A 232-channel epiretinal stimulator ASIC," in IEEE International Solid-State Circuits Conference, vol. 42, no. 12, pp. 2946-2959, Feb 2007.
[10] G. E. Loeb, R. A. Peck, W. H. Moore, et. al., "BION (TM) system for distributed neural prosthetic interfaces," Medical Engineering and Physics, vol. 23, no. 1, pp. 9-18, Jan 2001.
[11] M. Ghovanloo and K. Najafi, "A compact large voltage-compliance high output-impedance programmable current source for implantable microstimulators," IEEE Tran. on Neural Systems and Rehabilitation Engineering, vol. 15, no. 3, pp. 449-457, Sep 2007.
[12] Apparatus for Transmission of Electrical Energy, US patent 649,621, 1900.
[13] M. Catrysse M, B. Hermans and R. Puers, "An Inductive Power System with Integrated Bi-directional data-transmission," Sensors and Actuators A-Physics., vol. 115, no. 2-3, pp. 221-229, Sep. 2004.
[14] Z. Yang, W. Liu and E. Basham, "Inductor Modeling in Wireless Links for Implantable Electronics," IEEE Trans. on Magnetics, vol.43, no.10, pp. 3851-3860, Jun. 2009
[15] G. Bawa and M. Ghovanloo, "Active high power conversion efficiency rectifier with built-in dual-mode back telemetry in standard CMOS technology," IEEE Trans. Biomedical Circuits and Systems, vol.2, no.3, pp.184-192, Sept. 2008
[16] C. Hu and A. Niknejad, Modeling and BSIM4.4.0, MOSFET Model - User's Manual.: University of California, Berkeley, 2004.