Evaluation of Performance Requirements for Seismic Design of Piping System
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32794
Evaluation of Performance Requirements for Seismic Design of Piping System

Authors: Bu Seog Ju, Woo Young Jung

Abstract:

The cost of damage to the non-structural systems in critical facilities like nuclear power plants and hospitals can exceed 80% of the total cost of damage during an earthquake. The failure of nonstructural components, especially, piping systems led to leakage of water and subsequent shut-down of hospitals immediately after the event. Consequently, the evaluation of performance of these types of structural configurations has become necessary to mitigate the risk and to achieve reliable designs. This paper focuses on a methodology to evaluate the static and dynamic characteristics of complex actual piping system based on NFPA-13 and SMACNA guidelines. The result of this study revealed that current piping system subjected to design lateral force and design spectrum based on UBC-97 was failed in both cases and mode shapes between piping system and building structure were very different

Keywords: Nonstructural component, piping, hospital, seismic, bracing.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1059503

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2850

References:


[1] R. Reitherman, "Nonstructural Earthquake Damage," Construction of University for Research in Earthquake Engineering (CUREE), 2009, http://www.curee.org/image_gallery/calendar/essays/2010-CUREE_exce rpt.pdf.
[2] C. A. Kircher, "It Makes Dollars and Sense to Improve Nonstructural System Performance," Proceedings of Seminar on Seismic Design, Performance, and Retrofit of Nonstructural Components in Critical Facilities, ATC-29-2, 2003.
[3] J. M. Ayres and R. J. Phillips, "Water Damage in Hospital Resulting from the Northridge Earthquake," ASHRAE Transactions Part 1B, SF-98-14-2, 1286-1296, 1998.
[4] R. J. Wasilewski, "Seismic Restraints for piping System," ASHRAE Transactions Part 1B, SF-98-14-1, 1273-1285, 1998.
[5] John D. Gillengerten, "Recent and Future Developments in the NEHRP Seismic Provisions for Nonstructural Component Design," Proceedings of Seminar on Seismic Design, Performance, and Retrofit of Nonstructural Components in Critical Facilities, ATC-29-2, 2003.
[6] A. Filiatrault, C. Christopoulos and C. Stearns, "Guidelines, Specifications, and Seismic Performance Characterization of Nonstructural Building Components and Equipment," PEER Report 2002/05, 2001.
[7] UBC-97, 1997 Uniform Building Code, International Code Council, 1007.
[8] CBC-2010, 2010 California Building Code, International Code Council, 2010.
[9] NEHRP-2003, NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures (FEMA 450), Building Seismic Safety Council, 2003.
[10] NFPA-13, Standard for the installation of Sprinkler System, National Fire Protection Association, MA, 2007 Edition.
[11] SMACNA, Seismic Restraint Manual Guidelines for Mechanical Systems, Sheet Metal and Air Conditioning Contractors- National Association, Inc., 2003.