	  title     = {Appling Eyring-s Accelerated Life Testing Model to “Times to Breakdown“ of Insulating Fluid: A Combined Approach of an Accelerated and a Sequential Life Testing},
	  author    = {D. I. De Souza and  D. R. Fonseca and  D. Kipper},
	  country	= {},
	  institution	= {},
	  abstract     = {In this paper, the test purpose will be to assess
whether or not the accelerated model proposed by Eyring will be able
to translate results for the shape and scale parameters of an
underlying Weibull model, obtained under two accelerating using
conditions, to expected normal using condition results for these
parameters. The product being analyzed is a new type of insulate
fluid, and the accelerating factor is the voltage stresses applied to the
fluid at two different levels (30KV and 40KV). The normal operating
voltage is 25KV. In this case, it was possible to test the insulate fluid
at normal voltage using condition. Both results for the two
parameters of the Weibull model, obtained under normal using
condition and translated from accelerated using conditions to normal
conditions, will be compared to each other to assess the accuracy of
the Eyring model when the accelerating factor is only the voltage
stress.},
	    journal   = {International Journal of Chemical and Molecular Engineering},
	  volume    = {4},
	  number    = {9},
	  year      = {2010},
	  pages     = {556 - 561},
	  ee        = {https://publications.waset.org/pdf/4141},
	  url   	= {https://publications.waset.org/vol/45},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 45, 2010},
	}