WASET
	%0 Journal Article
	%A P. Guayjarernpanishkand and  T. Mayureesawan
	%D 2012
	%J International Journal of Mathematical and Computational Sciences
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 69, 2012
	%T The Comparisons of Average Outgoing Quality Limit between the MCSP-2-C and MCSP-C
	%U https://publications.waset.org/pdf/14277
	%V 69
	%X This paper presents a comparison of average outgoing
quality limit of the MCSP-2-C plan with MCSP-C when MCSP-2-C
has been developed from MCSP-C. The parameters used in MCSP-2-
C are: i (the clearance number), c (the acceptance number), m (the
number of conforming units to be found before allowing c nonconforming
units in the sampling inspection), f1 and f2 (the sampling
frequency at level 1 and 2, respectively). The average outgoing
quality limit (AOQL) values from two plans were compared and we
found that for all sets of i, r, and c values, MCSP-2-C gives higher
values than MCSP-C. For all sets of i, r, and c values, the average
outgoing quality values of MCSP-C and MCSP-2-C are similar when
p is low or high but is difference when p is moderate.
	%P 1319 - 1322