WASET
	%0 Journal Article
	%A M.E.Karbaschi and  R.Goudarzizadeh and  N.Hedayat
	%D 2011
	%J International Journal of Civil and Environmental Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 49, 2011
	%T Efficiency of Post-Tensioning Method for Seismic Retrofitting of Pre-Cast Cylindrical Concrete Reservoirs
	%U https://publications.waset.org/pdf/12653
	%V 49
	%X Cylindrical concrete reservoirs are appropriate choice
for storing liquids as water, oil and etc. By using of the pre-cast
concrete reservoirs instead of the in-situ constructed reservoirs, the
speed and precision of the construction would considerably increase.
In this construction method, wall and roof panels would make in
factory with high quality materials and precise controlling. Then,
pre-cast wall and roof panels would carry out to the construction site
for assembling. This method has a few faults such as: the existing
weeks in connection of wall panels together and wall panels to
foundation. Therefore, these have to be resisted under applied loads
such as seismic load. One of the innovative methods which was
successfully applied for seismic retrofitting of numerous pre-cast
cylindrical water reservoirs in New Zealand, using of the high tensile
cables around the reservoirs and post-tensioning them. In this paper,
analytical modeling of wall and roof panels and post-tensioned
cables are carried out with finite element method and the effect of
height to diameter ratio, post-tensioning force value, liquid level in
reservoir, installing position of tendons on seismic response of
reservoirs are investigated.
	%P 47 - 51