	  title     = {Design, Fabrication and Evaluation of MR Damper},
	  author    = {A. Ashfak and  A. Saheed and  K. K. Abdul Rasheed and  J. Abdul Jaleel},
	  country	= {},
	  institution	= {},
	  abstract     = {This paper presents the design, fabrication and
evaluation of magneto-rheological damper. Semi-active control
devices have received significant attention in recent years because
they offer the adaptability of active control devices without requiring
the associated large power sources. Magneto-Rheological (MR)
dampers are semi- active control devices that use MR fluids to
produce controllable dampers. They potentially offer highly reliable
operation and can be viewed as fail-safe in that they become passive
dampers if the control hardware malfunction. The advantage of MR
dampers over conventional dampers are that they are simple in
construction, compromise between high frequency isolation and
natural frequency isolation, they offer semi-active control, use very
little power, have very quick response, has few moving parts, have a
relax tolerances and direct interfacing with electronics. Magneto-
Rheological (MR) fluids are Controllable fluids belonging to the
class of active materials that have the unique ability to change
dynamic yield stress when acted upon by an electric or magnetic
field, while maintaining viscosity relatively constant. This property
can be utilized in MR damper where the damping force is changed by
changing the rheological properties of the fluid magnetically. MR
fluids have a dynamic yield stress over Electro-Rheological fluids
(ER) and a broader operational temperature range. The objective of
this papert was to study the application of an MR damper to vibration
control, design the vibration damper using MR fluids, test and
evaluate its performance. In this paper the Rheology and the theory
behind MR fluids and their use on vibration control were studied.
Then a MR vibration damper suitable for vehicle suspension was
designed and fabricated using the MR fluid. The MR damper was
tested using a dynamic test rig and the results were obtained in the
form of force vs velocity and the force vs displacement plots. The
results were encouraging and greatly inspire further research on the
topic.},
	    journal   = {International Journal of Mechanical and Mechatronics Engineering},
	  volume    = {3},
	  number    = {5},
	  year      = {2009},
	  pages     = {530 - 535},
	  ee        = {https://publications.waset.org/pdf/10225},
	  url   	= {https://publications.waset.org/vol/29},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 29, 2009},
	}